Laserfiche WebLink
Permit#: BI806-002 <br /> Site Address: 3311 WETMORE AVE <br /> Owner: BENGEN LLC <br /> Tenant: VISITIN6 AN6EL5 <br /> App.Qate: 6/1f201$ <br /> , � ABBREVIATIONS GENERAL NOTES VECINITY MAP SHEET INDEX PraposedUse: COMERCIAL <br /> Descriptian: TI FOR NEINTENANT <br /> � <br /> Q & or � AND LAM LAMINATED 1. ALL WORK ON THIS PROJECT SHALL BE IN CONFORMANCE WITH ALL LOCAL A0.01 COVER SHEEf <br /> � � ANGLE LAV LAVATORY CODES AND ORDINANCES AND SHALL CONFORM TO ALL LOCALLY ADOPTED PROJECT SITE Reviewed ey� �� a�t�.� �j 6� <br /> " AT LB LAG BOLT BUILDING CODES. 3311 WEfMORE AVE. �C�ffice Set �o�s�te set Fire/Plannin <br /> � g Set <br /> 0 CENTER LINE LBS POUNDS EVERETT, w,a sazoi A1.01 DEMOLITION PLAN <br /> � - EQUAL LP LIGHT POLE 2. CONSTRUCTION AND DEMOLITION OF BUILDINGS SHALL BE IN COMPLIANCE WITH <br /> �' # NUMBER LT LIGHT THE PROVISIONS OF THE 2015 INTERNATIONAL FIRE CODE, CHAPTER 14. A1.02 DEMOLITION CEILING PLAN <br /> � P PENNY LTS LIGHT SWITCH <br /> � L PERPENDICULAR 3. ALL WORK ON THIS PROJECT SHALL BE IN CONFORMANCE WITH THE <br /> �' PLATE OR PROPERTY LINE M MIRROR WASHINGTON STATE ENERGY CODE. EXTERIOR JOINTS AROUND WINDOWS AND ' A2.01 FLOOR PLAN <br /> � ROUND OR DIAMEi'ER MAX MAXIMUM DOOR FRAMES, OPENINGS BETWEEN WALLS AND �OUNDATION, BETWEEN WALL <br /> MB MACHINE BOLT PANELS; OPENWGS AT PENETRATIONS OF UTILIN SERVECES THROUGH WALLS, <br /> a6 ANCHOR BOLT Mc MEDICINE CABINET A6.01 REFLECTED CEILING PLAN $�7g <br /> ACT ACOUSTICAL TILE MDF FLOORS AND ROOFS; AND ALL OTHER SUCH OPENINGS IN THE BUILRING REGisTERE� <br /> � AD ABOVE DATUM MDO MEDIUM DENSITY OVERLAY ENVELOPE SHALL BE CAULKED, SEALED, OR WEATHER-STRIPPED TO LIMIT AIR ,€ '� RCHI CT <br /> � � � _� . . . m <br /> ADJ ADJUSTABLE OR ADJACENT MECH MECHANfCAL LEAKAG�. AIR LEAKAG€ SHALL BE LIMITED TO 1 CFM/FT� FOR ENTRY D04RS -`" �°" ` � - - <br /> � * <br /> AFF ABOVE FINISHED FLOOR M�D MEDIUM AND .2 CFM�FT2 �OR ALL OTkIER AREAS. � Scott Alan onnor <br /> � ' �. <br /> AL ALUMINUM MFR MANUFACTURER �� `��� � i STATE OF WASHINGTON <br /> ALT ALTERNATE MH MANHOLE 4. PROVIDE FIRE BLOCKING IN ALL CONCEALED SPACES aF COMBUSTfBLE µ � � <br /> -,� . t., �� � <br /> APN ACOUSTICAL PANEL MiN MINIMUM CONSTRUCTION INCLUDING• WALLS PARTITIONS FURRING AT CEILING AT <br /> ARCH ARCHITECT MISC MISCELlANEOUS FLOOR LEVELS, AT 10' INTERVALS� BOTH VERTICAt� AND HORIZONTAL,�AND AT � <br /> B.M. BENCH MARK N10 MASONRY QPENING ALL INTERCONNECTiONS BEfWEEN VERTfCAL AND HOR(ZONTAL SPACES. �� ' `"' `��� <br /> BD BOARD MOD MODIFY - SEE SECTION 717 / I.B.C. ���,�$� 1������µ � <br /> BFF BELOW FINISH FLOOR MR MOISTURE RESISTANT � - <br /> r � <br /> BLD�G BUILDING MT� MEfA� ED 5. ALL PENETRATIONS THROUGH RATED WALL ASSEMBLIES, FLOOR/CEILING AND - <br /> BLK G BLQCKING � � ���� � ���� <br /> BM BEAM MW MICROWAVE ROOF/CEILING ASSEMBLIES TO BE PROTECTED BY AN APPROVED FIRESTOP <br /> SYSTEM PER SECTION 712 / I.B.C. IN INALLS, THE APPROVED FIRESTOP oO <br /> � BOS BOTTOM OF STRUCTURE N NORTH SYSTEM SHALL HAVE AN 'F' RATING OF NOT LESS THAN THE REQUIRED RATING � <br /> BOT BOTTOM NFHB NON-FREEZE HOSE BIBB � <br /> iI� N <br /> BTWN BETWEEN NIC NOT IN CONTRACT OF THE WALL PE�IETRATED. IN HORIZONTAL ASSEMBLIES, THE APPROVED � <br /> NO NUMBER FIRESTOP SYSTEMS SHALL HAVE AN 'F' RATING AND A 'T' RAT{NG OF NOT N o <br /> C CLOCK OR COFFEE NOM NOMINAL LESS THAN 1 HOUR, BUT NOT LESS THAN THE REQUIRED RATING OF THE <br /> CABS CABINETS NTS NOT TO SCALE WALL PENETRATED. <br /> cc CENTERO' C NTERHALKBOARD o� PARCEL NUMBER & LEGAL DESCRIPTION: PROJECT DATA � <br /> ON CENTER 8. FIRE ALARM, FIRE SPRINKLER SUBMITTALS AND PERMITS SHALL BE DEFERRED. � <br /> CFCI CONTRACTOR FURNISMED & INSTALLED OD OUTSIDE DIAMETER m <br /> CFI CONTRACTOR FURNISHED ITEM OFCI OWNER FURNISHED 7. THE CONTf�ACTOR SHALL VISIT THE SITE �RIOR T4 BIDDING. IF PARCEL NUMBER: �' U' <br /> CH COAT HOOK CONTRACTOR INSTALLED NAME OF PROJECT: 3311 WETMORE AVE. PROJECT SCOPE: o ,- � <br /> CJ CONTROL JOINT OF01 OWNER FURNISHED, DISCREPANCIES ARE NOTED, THE CONTRACTOR SHALL CONTACT THE ARCHITECT TENANT IMPROVEMENT v, � <br /> CK. TP. COOK TOP OWNER INSTALLED PRIOR TO BIDDING FOR CLARIFICATION. 00436979200100 TENANT IMPROVEMENT TO EXISTING OFFICES TO BUILD w w H <br /> CL, CENTER LINE OFI OWNER FURNISHED ITEM O U T V I S I T I N G A N G E L O F F I C E S. � � <br /> OH OVERHEAD $• �F C O N F L I C T S A R E F O U N D D U R I N G B I D D I N G, B E T W E E N T H E D R A W I N G S A N D O R O W N E R A G E N T: B ENGEN LLC <br /> CLG CEILING � / � <br /> CLR CLEAR OHL OVERHEAD LiNE THE SPECIFICATIONS, THE CONTRACTOR SHALL SEEK WRITTEN CLARIFICATION, LEGAL DESCRIPTION: 4628 HOFF RD <br /> C M P C O R R U G A T E D M E f A L P I P E O P N G O P ENIN G B Y A D D E N D U M, F R O M T H E A R C H I T E C T O R P R O V f D E T H E M O R E E X P E N S f V E. LOTS 1. 2. 3. 4. 5 AND 6 BLOCK 792 PLAT OF EVERETT: DIV. A B E L L I N G H A M, W A 9 8 2 2 5 <br /> CMU CONCRETE MASONRY UNIT p POWER 9. UNLESS OTHERWISE NOTED, EXISTING ITEMS TO REMAIN ARE SHOWN IN A AS RECORDED IN VOL. 3 OF PLATS, PAGE 61 RECORDS OF CONTACT: Fred Bengen � <br /> C.O. CLEAN OUT PL PLASTIC LIGHTER LINE WEIGHT THAN NEW fTEMS. SNOHOMISH COUNTY, WASHINGTON. <br /> COL COLUMN P-LAM PLASTIC LAMINATE PROJECT ADDRESS: 3311 WETMORE AVE. <br /> CONC CONCRETE POC POINT OF CONNECTION 10. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN EVERETT, WA 98201 <br /> CONT CONTINUOUS PLYW PLYWOOD ON THE DRAWfNGS AND ACTUAL FfELD MEASUREMENTS. PROMPTLY NOTfFY THE a <br /> CPP CORRUGATED PLASTIC PIPE PP POWER POLE ARCHITECT IF DISCREPANCIES ARE FOUND. ARCHITECT: SCR ARCHITECTS W <br /> CPT CARPET PR PAIR 1916 Pike Place, Suite 12-367 <br /> CR CLASSROOM PSt POUNDS PER SQUARE iNCH = � Seattle, Washington 98101 � <br /> CORR CORRIDOR OR CORRUGATED 11. ITEMS NOTED AS TYPICAL ON ANY DRAWING SHALL APPLY TO ALL DRAWINGS. <br /> CT CERAMiC TILE ��L PARALLEL STRAND LUMBER PH: (206) 458-7517 <br /> CUST CUSTODIAN PT POINT 12. CIVIL, STRUCTURAL, MECHANlCAL, ELECTRICAL AND OTHER CONSULTANT CONTACT: Chris Reinhart O � <br /> CW COLD WATER PTD PAPER TOWEL DISPENSER DRAWINGS ARE DIAGRAMMATIC AND SUPPLEMENTARY TO THE ARCHITECTURAL <br /> � chris�SCR-arch.com � <br /> DBL DOUBLE QT QUARRY TILE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR & SUB � <br /> DEPT DEPARTMENT R RADIUS OR R{SER CONTRACTOR TO BID AND INSTALL THEIR WORK IN ACCORQANCE WITH THE � <br /> DTL DETAIL RB RUBBER BASE ARCHITECTURAL DRAWINGS. ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL PROJECT DESCRIPTION: TENANT IMPROVEMENT � <br /> DRAWWGS AND THE CONSULTING ENGINEER S DRAWINGS SHALL BE BROUGHT EX(STfNG OFFICES CONVERTED TO � <br /> DF DRINKING FOUNTAIN RD ROOF DRAIN TO THE ATTENTION OF THE ARCHITECT BY WRITTEN NOTlFICATION FOR <br /> DIA DIAMETER RECP ELECTRICAL RECEPTICAL C L A R I F I C A T I O N P R I O R T O T HE COMMENCEMENT OF THE WORK AFFECTED. NEW VfSITIN G A N G E L O F F I C E S <br /> DIFF DIFFERENCE REF REFRIGERATOR � <br /> DIM DIMENSION REV REViSIONS ESTIMATED PROJECT VALUE: � 225,000 <br /> DIV DIVISION REQ'D REQUIRED 13. THE CONTRACTOR SHALL PROTECT, REPAIR, MODIFY AND/QR REPLACE ALL _ <br /> DN DOWN RL RAIN LEADER UTILITIES, PAVEMENTS, PUBLIC & PRIVATE PROPERTIES, INSTALLATIONS, ACTIVITIES ON SITE: EXISTING OFFICE BUILDING � <br /> DR DOOR RM ROOM STRUCTURES, BUILDINGS OR PORTIONS 4F, ABOVE OR BELOW GROUND DURING APPLICABLE CODES <br /> DS DOWN SPOUT RO ROUGH OPENING THE COURSE OF CONSTRUCTION TO COMPLETE WORK SHOWN IN THE CODE DATA: W <br /> DW DISHWASHER RTD&WR RECESSED TOWEL DISPENSER CONSTRUCTION SET. NOT ALL PROTECTION, REPAIR, MODIFICATION OR ' <br /> DWG DRAWING AND WASTE RECEPTACLE REPLACEMENT REQUIRED IS SHOWN ON TNE DRAWINGS. THE CONTRACTOR � � <br /> (E) EXISTING RWL RAINWATER LEADER SHALL PROVIDE SUFFICIENT BUDGET TO COVER ALL PROTECTION, REPAtR, 2015 INTERNATlONAL BUILDING CODE (AMENDED RMC 15.08) JURISDICTION: CITY OF EVERETT <br /> MODIFICATION AND OR REPLACEMENT OF EXISTING UTILITIES PAVEMENTS 2015 INTERNATIONAL FlRE CODE (AMENQED RMC 15.06) <br /> E EAST S SOUTH OR SINK PUBLIC & PRIVATE PROPERTIES INSTALLATtON STRUCTURES BUlL01NGS �OR <br /> EA EACH S&P SHELF AND POLE � � <br /> EFC EPDXY FLOOR COVERING SCD SEAT COVER DISPENSER <br /> PORTIONS OF, ABOVE OR BELOW GROUND WITNIN THE B!D SUM. 2015 INTERNATIONAL MECHANICAL CODE (AMENDED RMC 15.14) AREA OF SITE: 18.000 SF <br /> EJ EXPANSION JOiNT SC SOLID CORE 2015 UNIFORM PLUMBING CODE AMENDED (AMENDED RMC 15.16) BUILDING AREA: FLOOR OF BUILDING: 3 650 SF � � <br /> ELEC ELECTRICAL SD SOAP DISPENSER THE REPAIR, MODIFICATION OR REPLACEMENT OF ANY EXtSTING UTtLITY, 2015 NATiONAL ELECTRICAL CODE (NFPA 70) (AMENDED RMC 15.12) ' <br /> EO ELECTRICAL OUTLET SHLV SHELVING PAVEMENT, PUBLIC & PRIVATE PROPERTY, INSTALLATION, STRUCTURE, BUILDING 2015 INTERNATIONAL PROPERTY MAINTENANCE CODE AMENDED RMC 15.10 � <br /> ELEV ELEVATION SHT SHEET OR PORTIONS OF, ABOVE OR BEIOW GROUND, SHALL MATCH THE ORIGINAL � ) O <br /> EQ EQUAL SHTHNG SHEATHING CQNDITION IN QUALITY, SUBSTANCE AND APPEARANCE. ACCESSIBLE & USABLE BUILDINGS & FACtLIT1ES (ICC/ANSI A117.1) � <br /> EQUIP EQUIPMENT SIM SIMILAR INTERNATIONAL BUILDING CODE WAC 51-50 (AMENDED) CONSTRUCTION HISTORY: STRUCTURE BUILT 1975 <br /> EWC EPDXY WALL COVERING SND SANITARY NAPKfN DISPENSER WHERE EXISTING WORK IS CHANGED, MODIFIED, OR NEW WORK AQJOINS, � � <br /> EXIST EXISTING SNR SANITARY N�PKIN R�CEPTACL.E CONNECTS TO OR ABUTS EXISTING, THE EXISTfNG WORK SHALL BE ALTERED (NTERNATIONAL MECHANICAL CODE WAC 51-52 (AMENDED) <br /> EXP EXPANSION SPECS SPECIfICATIONS AS NECESSARY, JOINED & CONNECTED IN A SUBSTANTfAL, NEAT AND iNfiERNA710NAL �IRE CODE WAC 51-54 (AMENDED) CONSTRUCTfON TYPE: TYPE Y�d�i � <br /> EXT EXTERIOR SQ SQUARE WORKMANSHIP MANNER. NEW MASONRY SHALL ALIGN WITH EXISTING COURSING. UNIFORM P�UMBING CODE WAC 51-56 & 51-57 (AMENDED) � <br /> SS STAINLESS STEEL OR FIRE SPRINKLERS: N0, NOT REQUtRED. � <br /> FC FILE CABINET S A N I T A R Y S E W E R 1 4. I T I S T H E R E S P O N S I B I L I T Y O F E A C H C O N T R A C T O R & S U B C O N T R A C T O R T 0 WASHINGTON STATE ENERGY CODE WAC 51-11 (AMENDED) <br /> FD FLOOR DRAIN OCCUPANCY: B <br /> F D N F O U N D A T f O N S T S W R S T O R M S E W E R R E V I E W A L L D R A W I N G S A N D S P E C I F I C A T I O N S I N C L U D I N G A D D E N D A T O I D E N T I F Y W�H I N G T O N S T A T E V E N T I L A T I O N A N D I N D O O R A I R Q U A L I T Y C O D E W A C 5 1-1 3 � <br /> F E F I R E E X T t N G U I S H E R STD STANDARD ALL WORK REQUIRED. THE CONTRACTOR OR SUB CONTRACTOR SHALL REVIEW � <br /> � STDPP STANDPIPE EACN DRAWING AND COORaINATE BETWEEN ALL PLANS AND SPECIFICATfONS. � .. <br /> FEC FIRE EXTINGUISHER CABIN�T' EACH SUB CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE BUILDING HEIGHT: 13 -0 +/- � <br /> STL STEEL FURTNER � <br /> � FF FINISHED FLOOR ' N0. OF STORIES: 1 <br /> STOR STORAGE GENERAL CONTRACTOR TO PROVIDE PROPER SEQUENCE PLACEMENT <br /> a . FH FIRE HYDRANT � � ���(�°�� <br /> �� STRUCT STRUCTURAL TOLERANCES AND REQUIREMENTS OF OTHER SUB CONTRACTORS. SUB <br /> FIN FlNISH :����1� & CG��° � <br /> SUSP SUSPENDED CONTRACTORS SHALL BE RESPONSIBLE FOR THE REMOVA� & REPLA�CEMENT HEATING: FORCED AIR GAS <br /> `�W FLR FLOOR SVF SHEET VINYL FLOORING OF THEIR WORK THAT MUST BE MODIFIED, REPLACED, REPAIRED OR aVElO¢' <br /> �� FRP FIBERGLASS REINFORCED PLASTIC ~"'��� <br /> �a FT FOOT OR FEET SWC SPECIAL WALL COATING OTHERWISE ALTERED TO ACHIEVE THE DESIGN ItdTENT 4R CODE REQUIREMENT � <br /> FTG FOOTING DUE TO LACK OF COORDINATION WITH THE GENERAI CONTRACTOR. 2 c� j �' <br /> �� T TILE OR TREAD � <br /> =o GALV GALVANIZED TB TACK BOARD OR TOWEL BAR W <br /> �Z GB GRAB BAR TD TOWEL DISPENSER OR TRENCH DRAfN SYMB�LS LEGEND � <br /> `"� GE GLOSS ENAMEL T&G TONGUE AND GROVE <br /> � DESIGN TEAM <br /> GFB GYPSUM FIBER BOARD TEMP TEMPERATURE � <br /> "� GL GLASS TME TO MATCH EXISTING <br /> _ � <br /> �Q GM GWB GLASS MAT GYPSUM WALL BOARD TOIL TOILET BUILDING SECTION NUMBER OWNERS REPRESENTATIVE: ARCHITECT: <br /> Z GV GATE VALVE TOM TOP OF MASONRY �o; a_.�: CONCRETE � STEEL r <br /> �� GWB GYPSUM WALL BOARD TOP TOP OF PLATE � DRAWIPJG SHEET NUMBER Loomis Construction SCR ARCHITECTS � <br /> (large scale) 1217 22nd St �916 Pike Place r <br /> �3 GYP GYPSUM TOS TOP OF STEEL Snohomish WA 98290 Sui � <br /> a� H$ HOSE BIBB TP TEST PIT 40 SECTION NUMB�R � tG 12-367 <br /> TPH TOILEf PAPER HOLDER .I CONCRETE / / GLASS Washin ton 98101 � � <br /> HC HANDICAPPED DRAWING �HEET NUMBER � � � PH: (425) 344 5353 Seattle, g <br /> �� TFMR TRANSFORMER smail scale <br /> �= HD HAND DRIER C � <br /> PH: 206 458-7517 � � <br /> �� HDBD HARDBOARD TVp TYP CA ALL DETAIL NUMBER �%��%'%���� EARTH CONTACT: Tony Loomis � � <br /> . �w HDWD HARDWOOD DRAWING SHEET NUMBER �RAVEL � �����"��� IoomisconstC�➢aol.com CONTACT: CHRIS REINHART <br /> -� � �;.�,� <br /> _� HM HOLLOW MEfAL UPC UNIFORM PLUMBING CODE � ���,x,�� ' �� ��� (undisturbed� chrisC�?scr-arch.com <br /> � Qa HO HOLD OPEN UG UNDERGROUND LICENSE: COVER SHEET <br /> � HR HOUR UL UNDERWRITERS LABORATORY � <br /> � � � --� � _ EARTH <br /> �� HT HEIGHT UNFIN UNFINISHED 6 1NTERIOR ELEVATION , . � _ W��p ' * <br /> =Z HW HOT WATER UON UNLESS OTHERWISE NOTED �5.1 DRAWING SHEET NUMBER �'� � milled � ' (fill} loomic 169pa EXP: 8/12/2019 � � <br /> oQ HWG HIGH WALL GRILLE UP UTILITY POLE � <br /> - � ) ���������c���r� ��s�av�r��� aL;;� <br /> �o HWH HOT WATER HEATER UV UNIT VENTILATOR <br /> � APBR�WO�K�THE 1SSUANCE OF <br /> o HWR HOT WATER RETURN PU MECHAMC^'� , ���� <br /> n- - VNR VENEER ��) DOOR NUMBER � WOOD � PLYWOOD p�pPRE��p R'ETESTR��'. " "' <br /> Z� HWS HOT WATER SUPPLY VCT VINYL COMPOSITION TfLE (framing) � � <br /> HWT HOT WATER TANK VEST vESTIBU�E ASPHALT <br /> ZZ r 1 <br /> IBC INTERNATIONAL BUILDING CODE VG VERTICAL GRAIN <br /> Wo 1FC INTERNATIONAL FIRE CODE VWF V1NYL WALL FABRIC � ROOM SIGNAGE LOCATION ;k C� �x, INSULATION <br /> �� ID INSIDE DIAMETER (rigid) <br /> --- (large scale) <br /> Z� IE INVERT ELEVATION W WEST dFor This Project To I cl de � <br /> NZ INSUL INSULATION W� W�TH ( WINDC�W TYPE � , �� _== ASPHALT D R A W N B Y: C M R <br /> 0o INT INTERIOR W/0 WITHOUT �`�` , � � � INSULATIO�J � �small scale) � Plumbing O Sprinkls�: DATE: 05 24 2018 <br /> INV INVERT WB WHITE BOARD '`�` � (batt� <br /> oW IP IRRIGATION PIPE WD WOOD � � ' / / <br /> �� MechanicaA `��� � �������-�� ��� <br /> Zm WIN WINDOW <br /> Zo JST JOIST WGL WIRE GIASS a �ouvER TYPE `?� Fle�tric�4 <br /> jo JT JOINT WM WATER MAIN <br /> "Z KD KNOCK DOWN WP WEATHERPROOF .r � �� �v��� ' <br /> �� KIT KITCHEN WR WASTE RECEPTACLE 15 GRiD LINES <br /> - :J,_��-. r� ._,� ,�� � . , <br /> �Q KPL KICK PLATE WyvM WOVEN WIRE MESH A� . <br /> ■ <br />