916 OAKES AVE 2018 WHITTIER ELEMENTARY SCHOOL Plans 2022-12-27
>
Address Records
>
OAKES AVE
>
916
>
WHITTIER ELEMENTARY SCHOOL
>
Plans
>
916 OAKES AVE 2018 WHITTIER ELEMENTARY SCHOOL Plans 2022-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 1:58:09 PM
Creation date
3/12/2019 8:23:13 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
916
Tenant Name
WHITTIER ELEMENTARY SCHOOL
Permit
B1803-049
Year
2018
Notes
INSTALL 1 NEW PORTABLE LANDING AND STAIRS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 2 ' <br /> VIA PC3 ,5�7 O <br /> O #3 � <br /> GENE <br /> RAL NOTES: <br /> �5 VIA PC5 <br /> A <br /> O <br /> D WIRE tS USED ALL TERMINATIONS ARE MADE BY <br /> 1. WHEN STRANDE , <br /> A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br /> (2) 8' x �' WHITE BOARDS w/ 3 5 � ,.`�� OR OTHER APPROVED MEANS OF TERMINATION. <br /> MARKER TRAY (SHIP LOOSE) PCPCPC ELECTRIC ' <br /> INSTALLED ON SITE BY OTHERS PANEL 2. ALL CONDUCTORS ARE COPPER;TYPE THHN/THWN <br /> f 1 f <br /> O C� O 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br /> b b b <br /> -- - -- �- - - - - - - - - - - - — - - - - - - - - - - � 1 <br /> # <br /> 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE <br /> WP <br /> � GFCI ' <br /> I #2�4 5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> � <br /> PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br /> � WAC 296-46$-1 10 022 <br /> I <br /> ONE-LINE-DIAGRAM <br /> � I 6. EXTERIOR WEATHER PROOF GFG SHA�L HAVE A "HEAVY DUTY" 100 AMP FEEdER PANEL <br /> t WEATHER PROOF"fN USE"COVER. 2014 NEC 406.9(B)(1) MAIN BREAKER <br /> C -- - -, -- - - - - - - - - - - -- -- - - - - - -- - - - -_ -- - -- � <br /> l r 120 f 240 1� <br /> � � 7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC <br /> 1 l 1 � � P P � 100 AMP <br /> Q O O WITH THE TEXT"CONTROLLED"AND THIS SYMBOL <br /> b <br /> b 406.3(E) <br /> b oT U <br /> co _ _ _ _ _ _ _ _ _ _ _ _ _ <br /> nPP16 POWER $• THIS PLAN IS NOT AN"AS-BUILT'CIRCUITS MAY BE RUN DIFFERENT <br /> 1 2" PVC 1-1/2" PVC STUB THRU <br /> THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br /> � <br /> PACK TO S(GNAL ST B FOR BY BLAZER <br /> � U <br /> THERMOSTAT 2 2 Cu THHN • <br /> FUTURE <br /> � ) # <br /> � OCCUPIED PERIOD GROUNDING 1 4 Cu THHN <br /> � AND (1> #6 Cu <br /> � ) # <br /> � 1 BONDING (WIRE ON SITE BY dTHERS) <br /> � - WSEC CHAPTER 4 NOTES: <br /> U <br /> 51 11 C WAC 2015 � <br /> � <br /> � <br /> a <br /> - - - - - - - -- - - - - - - - - - - - - - - -- Q <br /> S <br /> 1. ALL LIGHTING SHALL CONFORM TO SECTION C405 <br /> 1 � <br /> } O p O q a � 2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) PANEL SCHEDULE <br /> 833 SQ. FT,x 1 WATT PER SQUARE FOOT=833 WATTS ALLOWED <br /> � NOTE: ALL CONDUCTORS COPPER. 100 AMP 1� 22,000 AIC <br /> � ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) <br /> CKT TRIP WIRE VOLT 'IOO VOLT WIRE TRIP CKT <br /> I 833 WATTS ALLOWED (BASE) x.75= 625 WATTS ALLOWED DESCRIPTION DESCRIPTION <br /> N0. AMPS SIZE AMPS ,q B AMPS SIZE AMPS NO. <br /> � I 1 LIGHTS 20 12 552 �� �� 7052 4 80 HVAC 2 , <br /> TOTAL WATTS ALLOWED = 625 i"� /'� <br /> �\ TOTAL WATTS INSTALLED =477 WATTS 3 RECEPTACLES 20 �2 �260 — 7052 / / / 4 <br /> 0 0 %OF ALLOWED INSTALLED — 76% 5 RECEPTACLES 20 12 to8o � � SPACE 6 <br /> 7 RECEPTACLES 20 12 900 — — — — — SPACE 8 <br /> � 3. 100%OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 9 sPacE — — — —� � — — — s�acE �o <br /> SPAGE — — — — — — — SPACE 12 <br /> AND RE — <br /> DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, A 11 <br /> INDIVIDUALLY ADDRESSABLE. (C406.4) 13 SPACE — — — � � — s�acE �q <br /> 15 SPACE — — — — — — — — SPACE 16 <br /> 4. 100%OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS �� sPacE — — — —�� �� — — — sPac� �a <br /> ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA 19 SPACE — — — �\ �\ — SPACE 20 <br /> WALL PODS, (C406.4) <br /> ELECTRICAL PLAN <br /> ; 5. 50%OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY E L E C T R I C A L S Y M B O L S <br /> SENSORS (C405.10) ' <br /> 1/4" = 1'-0" ARS 9/25/2017 AFF <br /> SYMBOL DESCRIPTION TO TOP REMARKS <br /> 6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE Xx nLIGHT DIMMING CONTROL DIMMING CONTROL. LOWER CASE <br /> nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING '�'� SWITCH CATSE CONNECTED 48 LETTERS DESIGNATE ZONING <br /> FIXTURES. <br /> H.V.A.C. (MOTOR, COMPRESSOR, HEATER SIZES) PC PLIUG LOAD2CONTROL RELAY CEI�NG FIXNURELOCCUPANCYH ENSORSED <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. nLIGHT nPP16 THERMOSTAT ABOVE CONTROLLED BY nLIGHT ENABLED <br /> ' COMPRESSOR 11,8 RLA 83 LRA ELECTRICAL PLAN REVIEW PP CONTROL RELAY CEILING FIXTURE OCCUPANCY SENSORS <br /> i; <br /> OUTDOOR FAN 2.5 FLA 1/5 H.P. LOAD CALCULATIONS <br /> INDOOR BLOWER FAN 2.8 FLA 1 3 H.P. �TR DUPLEX RECEPTACLE 20» 180 VA EACH <br /> � HALF CONTROLLED HALF HOT TAMPER RESISTANT <br /> HEAT STRIP 10 KVA rR QUADPLEX RECEPTACLE 180 VA EACH <br /> MINIMUM CIRCUIT AMPS 79 AMPS VOLTAGE: 120/240 PHASE: 1� � HALF CONTROLLED HALF HOT 20 TAMPER RESISTANT <br /> MAX�MUM -0VERCURRENT PROTECTION $O AMPS NOTE: ALL DEVICES 8c FACE CONNECTE� �oAo CALC. LOAD a SINGLE RECESSED CLOCK 84�� 180 VA EACH <br /> OVERCURRENT PROTECTION— DUAL ELEMENT TIME DELAY FUSE PLATES TO BE IVORY � � HANGER RECEPTACLE <br /> � <br /> LIGHT NG <br /> OR HACR CIRCUIT BREAKER <br /> EXTERIOR 75 VA x 125 % = 94 VA �c ci WEATHER RESISTANT GFCI 20" 180 VA EACH <br /> RECEPTACLE <br /> QTY. SIZE DESCRIPTION �NTER�oR 477 VA x 125 % = 596 VA , PHONE / DATA BOX 20" 4" SQ BOX SING�E GANG MR WITH <br /> 3/4" CONDUIT UP AND DOWN <br /> ELECTRICAL PANEL 1 100 120/240V — SING�E PHASE — STUB THRU — METALLIC RACEWAY SYSTEM RECEPTACLES � FIRE ALARM PU�L STATION 48" <br /> THRU10,000 3240 VA x 100 % = 3240 VA 4" SQUAR� BOX w/ SINGLE GANG MUD <br /> 9 2 x 4 �ED VOLUMETRIC TROFFER— n�IGHT ENABLED— 6000 LUMEN— 53 WATTS— 4000K FIRE ALARM INTERIOR 84» RING — 3/4" RACEWAY STUB uP ON�Y <br /> WITH EMBEDDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATING ON CATSE OVER 10,000 0 VA x 50 % = 0 VA � HORN / STROBE PAWT BOX, MUDRING AND RACEWAY <br /> LIGHTING �oca� N�TwoRK LITHONIA — BLT460LADPEZ1LP840N100NES7ADCX "RED" W COLOR <br /> MOTORS, COMPR. � FIRE ALARM EX7ERIOR 84„ <br /> HORN / STROBE <br /> 1 72 WATT LED WALL PAGK w/ INTEGRAL PHOTOCELL ECONOLIGHT E—WP11L07CZ / E—ACP1 TOTAL 4104 VA x 100 % = 4104 VA ' <br /> , T THERMOSTAT 48» 4" SQ BOX SINGLE GANG MR WITH <br /> HVAC 1 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ INTEGRAL ERV— 11 EER RATED �ARGEST (2832) VA x 25 % = 708 VA O 1/2" CONDUIT STUB UP <br /> HEATING 10000 VA x 100 % = 10000 VA LED WALL PACK 84" 75 VA EACH <br /> THERM�STAT 1 BARD 8403-060 w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE AUTOMATIC SETBACK— I� <br /> DEADBAND CONTROL — OCCUPANCY INTEGRATED INTO n�IGHT SYSTEM <br /> 1 BARD CMC-29 FREEZE STAT O nLIGHT ENABLED LED TROFFER <br /> TOTAL KVA �7.gO TOTAL KVA 18.74 C� w/ INTEGRAL SENSORS CEILING 53 VA EACH <br /> CO2 SENSOR 1 BARD 8403-067 — DEMAND CONTROL VENTIL,ATION CONNEGTED CA�Cu�ATE� <br /> LOAD AMPS 7�}.rj�] LOAD AMPS 78,09 B ELECTRICAL PANEL 72" <br /> 7-17-17 ELECTRICAL ENGINEERING ARS COPYRIGHT 2017, BLAZER INDUSTRIES, ��vc. � MODULAR C/assroom for.� Approved for Const: .lob No: 99031 <br /> 9-25-17 REDUCED PANEL SIZE TO 100 AMP � ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> , OF BLAZER INDUSTRIES, INC.AND SHALL ■■ 28 x 32 KC DA - Eve rett S�D■ File Copy: . <br /> ,' NOT BE REPRODUCED, USED,OR DISCLOSED � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,wC. Drawn By: LDG � <br /> DATE REVISION BY WRVTTEN PERMISSION OF BLAZER INDUSTRIES. �� www.blazerind.com Wq. GOLD Pacific Mobile 17 BLMP-04 A9 WA <br /> �� P.O.BOX 489 ■ Aumsville,OR 97325-0489 Issue Date: 9-25-17 <br /> i <br />