Laserfiche WebLink
• <br /> Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: Rainier Title Date 5/21/2018 <br /> Calculation ONew Construction <br /> O Addition- O Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> 0 Spaces where<50%of O Spaces where 50%of O Spaces where the Use <br /> luminaires are replaced luminaires are replaced is changing(C505) <br /> LPA ® Standard Q Additional Efficiency Package Option O <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. User Note <br /> Maximum Allowed Lighting WattageNoTE , <br /> Watts Allowed <br /> Location(plan#, Gross Interior Allowed (watts/ft2 x area) <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 NOTE 2 <br /> Office ALL Tenant suite 5673 0.66 3745 <br /> Total 5673 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 3,a,s,6 Fixtures Fixture NOTE Watts Proposed <br /> Office Room 100, 101, new/relocated fluoresent recessed can down lights 38 25 950 <br /> 112,118 <br /> Office 102-111, 113-117 new/relocated 2x4 fluorescent lights 55 50 2750 <br /> Compliance by Building Area NOTE 8 <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Office 3745 3700 COMPLIES <br /> • <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 3745 ' 3700 <br /> project scope. Select building area category from drop down menu. <br /> Note 2-Unlit Message-Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting <br /> Power Allowance. <br /> Note 3-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or <br /> 50 watts/lineal foot.or enter the wattage limit of permanent current limitino device. <br />