My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4004 COLBY AVE 2019-03-14
>
Address Records
>
COLBY AVE
>
4004
>
4004 COLBY AVE 2019-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2019 10:32:38 AM
Creation date
3/14/2019 10:32:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4004
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and E1ctrical Permit Checklist, Pg. .4 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> The Everett Clinic-Dermatology Clinic Remodel Date 9/13/2018 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING ALTERATIONS <br /> Where Z 50%of existing luminaires in interior space(s)or <br /> parking garage are replaced;indicate compliance path(building <br /> area or space-by-space method);include all new and existing-to LTG Checklist <br /> remain luminaires in compliance form(LTG-INT-BLD or LTG- <br /> INT-SPACE);indicate proposed lighting wattage does not <br /> Interior and parking exceed maximum allowed per compliance path <br /> yes C503.6 garage lighting <br /> fixture alterations Where<50%of existing luminaires in interior space(s)or <br /> parking garage are replaced;indicate total existing lighting <br /> wattage in each space prior to alteration;include all new and <br /> existing-to-remain luminaires in LTG-INT-SPACE form;indicate <br /> proposed total lighting wattage in alteration area does not <br /> exceed total existing lighting wattage prior to alteration <br /> Where Z 50%of existing exterior lighting wattage is replaced; <br /> include all new and existing-to-remain luminaires in LTG-EXT <br /> form;indicate proposed total exterior lighting wattage does not <br /> exceed maximum allowed <br /> NA C503.6 Exterior lighting Where<50%of existing exterior lighting wattage is replaced; <br /> fixture alterations <br /> indicate total existing lighting wattage prior to alteration;include <br /> all new and existing-to-remain luminaires in LTG-EXT form; <br /> indicate proposed total exterior lighting wattage does not exceec <br /> total existing wattage prior to alteration <br /> Where new wiring is installed to serve new interior luminaires <br /> Interior lighting wiring and/or luminaires are relocated to a new circuit;indicate <br /> Yes C503.6 alterations lighting controls are provided(as applicable)-manual Sheet A-131 <br /> (C405.2.3);occupancy sensor(C405.2.1);daylight responsive <br /> (C405.2.4);specific application(C405.2.5);exit signs(C405.3) <br /> Exterior lighting Where new wiring is installed to serve new exterior luminaires <br /> NA C503.6 wiring alterations and/or luminaires are relocated to new circuit;indicate exterior <br /> ' lighting controls are provided(C405.2.7) <br /> Where a new lighting panel is installed or an existing panel is <br /> Lighting panel moved(all new raceway and conductor wiring);indicate lighting <br /> NA C503.6 controls are provided(as applicable)-same provisions as <br /> alterations wiring alterations;time switch controls and manual light <br /> reduction controls(C405.2.2) <br /> Where interior space(s)is reconfigured(permanently installed <br /> Interior space walls or ceiling-height partitions);indicate lighting controls are <br /> Yes C503.6 Sheet A-131 <br /> reconfiguration provided(as applicable)-same provisions as lighting panel <br /> alterations <br /> Identify existing luminaires being upgraded with bulb and/or <br /> NA C504.2 Lighting repairs ballast replacement;indicate fixture alteration does not increase <br /> existing fixture wattage <br /> Identify spaces on plans where the building area type or space <br /> use type is being changed from one type to another per Tables <br /> C405.4.2(1)or(2) <br /> NA C505.1 Change of space use Indicate compliance path(building area or space-by-space <br /> method);include all new and existing-to-remain luminaires in <br /> compliance form(LTG-INT-BLD or LTG-INT-SPACE);indicate <br /> proposed lighting wattage does not exceed maximum allowed <br /> per compliance path <br /> RECEPTACLES <br /> Identify all controlled and uncontrolled receptacles on electrical <br /> plans in each space in which they are required;include <br /> Controlled receptacle configuration such as spacing between controlled <br /> NA C405.10 and uncontrolled,duplex devices,etc; <br /> receptacles <br /> Indicate on plans whether the method of automatic control for <br /> each controlled receptacle zone is by occupant sensor or <br /> programmable time-of-day control <br />
The URL can be used to link to this page
Your browser does not support the video tag.