My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4004 COLBY AVE 2019-03-14
>
Address Records
>
COLBY AVE
>
4004
>
4004 COLBY AVE 2019-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2019 10:32:38 AM
Creation date
3/14/2019 10:32:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4004
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - Spal. e-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: The Everett Clinic-Dermatology Clinic Remodel Date 9/13/2018 <br /> Calculation 0 New Construction O Addition- O Addition For Building Department Use <br /> Area NOTE° stand alone +existing <br /> O Spaces where<50%of O Spaces where z 50%of O Spaces where the Use <br /> luminaires are replaced luminaires are replaced is changing(C505) <br /> LPA ® Standard O Additional Efficiency Package Option <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. User Note <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Height'-'" Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> 157 Lounge/breakroom:health care facility 9 81 0.740 60 <br /> 142 Health care facility:Medical supplies 9 86 0.590 51 <br /> 9 <br /> 9 <br /> 9 <br /> 9 <br /> 9 <br /> 9 <br /> 9 <br /> Total Area 167 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 111 <br /> Proposed Lighting Wattage"'r' <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed <br /> 157 L-1 -2X4 RECESSED LED 1 31 31 <br /> 142 L-2 1x4 RECESSED LED 2 31 62 <br /> X-1 (EXISTING FIXTURE TO BE RELOCATED WITHININ <br /> 158 SAME SPACE) <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 93 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage.Enter all proposed lobby art/exhibit display <br /> fixtures in LTG-INT-DISPLAY form only. IV <br /> Note 9-Calculation Area Details: (v <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br />
The URL can be used to link to this page
Your browser does not support the video tag.