My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4225 RIVERFRONT BLVD 2019-03-14
>
Address Records
>
RIVERFRONT BLVD
>
4225
>
4225 RIVERFRONT BLVD 2019-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2019 1:17:51 PM
Creation date
3/14/2019 1:17:47 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
4225
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEDESIGN FIELD REPORT <br /> 1 of 3 <br /> Project Name: ' Everett River Front-Simpson Report 109 <br /> q <br /> GeoDesign#: i Polygon-127-03 __ _ Date: 6/8/2018 <br /> Reports with Unresolved Nonconformance Issues: — Permit: <br /> PW1505-005 <br /> .. vim . <br /> 1 Nick Abdelnour(Polygon) I Randy Allen(City of Everett) j Weather: Clear, 60's <br /> 0815/0900 <br /> Ron Bowen(Polygon) ,_ Eddy Stevens(Polygon) t Arrival/Departure: <br /> Distribution: ' _..__ _a.---------- ..�__.. <br /> 1 Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> 1.j Paul McKee(City of Everett) , Dave Foster(City of Everett) Prepared By: Ben Weinberg, P.E. <br /> m Site Plan(s) m Density Test Summary Signature: ��f»i <br /> Attachments. — — <br /> ❑ Installation Records ❑ Other Reviewed By: <br /> PURPOSE of VISIT: GeoDesign representative, Ben Weinberg, was on-site part time at the request of Craig with DDS to <br /> observe foundation subgrade for Lots 151 and 152. <br /> SUMMARY OF OBSERVATIONS: <br /> Lot 151: <br /> Upon arrival, GeoDesign noted that DDS had completed excavation of the foundation and crawl space area for Lot 151. <br /> The exposed soil across the lot area typically consisted of a gray-brown silty SAND with gravel which could be probed less <br /> than 1 inch using a 1/2 inch diameter soil probe. <br /> Relative compaction of the exposed foundation subgrade soil was tested using a Troxler Moisture-Density gauge; in-place <br /> density tests indicated that the material had been compacted to greater than 95% of its maximum dry density as determined <br /> by a Modified Proctor analysis. <br /> It is our opinion that the exposed foundation subgrade observed today is currently suitable for support of the intended <br /> structure. GeoDesign recommends that any surficially loose and saturated material that may be generated be removed from <br /> the base of foundation areas prior to the placement of concrete. <br /> Lot 152: <br /> Upon arrival, GeoDesign noted that DDS had completed excavation of the foundation and crawl space area for Lot 151. <br /> The lot area required over-excavation up to 1.5 feet below plan subgrade across the lot area, with the deepest portion in the <br /> garage area. DDS noted that the installed sewer lateral is beneath the north perimeter footing; they intend on excavating <br /> and re-plumbing the sewer lateral prior to backfilling the area with 5/8-inch crushed rock material placed in lifts and <br /> compacted with a hoepack. The exposed subgrade across the lot area typically consisted of a gray to brown silty SAND <br /> with gravel which could be probed less than 2 inches using a 1/2 inch diameter soil probe. <br /> Relative compaction of the exposed foundation subgrade soil was tested using a Troxler Moisture-Density gauge; in-place <br /> density tests indicated that the material had been compacted to greater than 95% of its maximum dry density as determined <br /> by a Modified Proctor analysis. <br /> It is our understanding that the contractor will be backfilling the over-excavated portion of the lot area and fixing the sewer <br /> lateral beneath the north perimeter footing at a later date. <br /> A summary of our observations and density tests taken today can be found in the attached Figure 1 and Nuclear Density <br /> Gauge Data. The contractor was notified of our observations. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not indude supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. ---,,,� <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 @i( <br />
The URL can be used to link to this page
Your browser does not support the video tag.