My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4423 RIVERFRONT BLVD 2019-03-14
>
Address Records
>
RIVERFRONT BLVD
>
4423
>
4423 RIVERFRONT BLVD 2019-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2019 4:06:54 PM
Creation date
3/14/2019 4:06:49 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
4423
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GE SIGNK FIELD Rn of <br /> Project Name: I Everett River Front-Simpson Report: 035 <br /> GeoDesign#: Polygon-127-03 Date: 05/03/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> •,T.,___•••-• �. .. <br /> :r : ..,�w _.� �., .�`-,._��.:�.�,. �....�.,�-��,.��t.....�t.�-:�,.n.�.,..,�, .7-=>: <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather Clear,50's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 1630/1700 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> m Site Plan(s) m Density Test Summary Signature: 4:- <br /> Attachments: 0 Installation Records m Other Reviewed By: <br /> SUMMARY of OBSERVATIONS (CONTINUED): <br /> .41,11 <br /> GeoDesign noted that DDS over-excavated sections of Lot 236 down to material which had been compacted to <br /> 9 P <br /> greater than 95%of its maximum dry density as determined by a Modified Proctor analysis. Today, GeoDesign noted that <br /> DDS had backfilled the over-excavated areas with a 2-inch clean crushed railroad ballast material which had been <br /> compacted using the bucket of an excavator. <br /> It is the opinion of GeoDesign that the foundation subgrade area observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any surficially loose and saturated material be removed from the base of <br /> the footing areas prior to the placement of concrete. <br /> Lot 238: <br /> Upon arrival, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 238. <br /> GeoDesign noted that the exposed foundation subgrade consisted of a gray to gray-brown silty SAND (f-m)with gravel(f-c) <br /> and a brown SILT with sand. Penetration depths along the north side were generally less than 2 inches using a 1/2 inch <br /> diameter soil probe. Penetration depths along the west,south,and east sides ranged from 6 Inches to 18 inches. <br /> GeoDesign recommended that the areas be over-excavated down to firm and unyielding material and brought back to <br /> grade with structural fill. <br /> Craig with DOS stated that the over-excavated areas would be over-excavated and backfilled with a crushed rock or <br /> recycled concrete material later this week. <br /> The client and contractor were notified of our observations prior to our departure from the site. <br /> A summary of our observations and density tests can be found in the attached Figure 1, Nuclear Density Gauge Data,and <br /> Photo Log. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations,The report can only be considered <br /> Final upon review of the GeoDesign project manager,as Indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.