My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4512 RIVERFRONT BLVD 2019-03-14
>
Address Records
>
RIVERFRONT BLVD
>
4512
>
4512 RIVERFRONT BLVD 2019-03-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2019 4:35:15 PM
Creation date
3/14/2019 4:35:10 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
4512
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CEODESIGNu FIELD REPORT <br /> 1 of 2 <br /> Project Name: Everett River Front- Simpson Report: 091 <br /> GeoDesign#: Polygon-127-03 Date: 1/29/2018 <br /> I Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> i <br /> 1 . <br /> Nick Abdelnour(Polygon) ! Randy Allen(City of Everett) Weather: Cloudy, 40's <br /> Ron Bowen(Polygon) ' Eddy Stevens(Polygon) Arrival/Departure: 1015/1045 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) i.Dave Foster(City of Everett) Prepared By: Ben Weinberg, EIT <br /> im Site Plan(s) 0 Density Test Summary Signature: 4-- 1 <br /> Attachments: <br /> ❑ Installation Records 0 Other Reviewed By Jai' ti.ti"7 --c. <br /> PURPOSE of VISIT: GeoDesign representative, Ben Weinberg,was on-site part time at the request of Craig with DDS to <br /> observe foundation subgrade for Lot 215 and 281. <br /> SUMMARY OF OBSERVATIONS: <br /> Lot 281: <br /> Previously, GeoDesign identified an approximately 15 feet long and 15 feet wide triangular area in the northeast corner of <br /> Lot 281 which could be probed 1-3 feet using a 1/2 inch diameter soil probe and required the removal of 1.5-4 feet of <br /> unsuitable material to expose firm and unyielding soil. Today, GeoDesign noted that the contractor had completed <br /> backfilling of the over-excavated area with a 2-inch clean crushed rock material compacted into a firm and unyielding mass. <br /> It is the opinion of GeoDesign that the exposed foundation subgrade observed today is currently suitable for Support of the <br /> intended structure. GeoDesign recommends that any surficially loose and saturated material that may be generated prior to <br /> placement of concrete be removed from the base of the footing areas. <br /> 40 2151. <br /> Upon arrival, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 215. <br /> GeoDesign noted that the exposed foundation subgrade area generally consisted of a gray-brown silty SAND (f-m)with <br /> gravel (f-c)which could be probed less than 2 inches. <br /> GeoDesign identified three areas across the lot area which could be probed 6 inches to 3 feet using a 1/2 inch diameter soil <br /> probe and was unsuitable for support of the intended structure. The deepest penetration depths were noted along the west <br /> and south side of the lot area; it appeared that previous over-excavation and replacement of material along the edges of the <br /> excavation was ineffective or that the over-excavation was not adequately extended beyond the building perimeter. <br /> A summary of our observations can be found in the attached Figure 1. <br /> GeoDesign notified the contractor that the areas were currently unsuitable for support of the intended structure and would <br /> require over-excavation down to firm and unyielding soil and replacement with structural fill material. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations. The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 ' <br />