GEOTECHNICAL ENGINEERING STUDY <br />Cascasia Pacific Properties, Ltd. <br />July 15, 1999 <br />E-8602 <br />Page 5 <br />Due to the proposed below -grade level planned for the development, construction of <br />temporary slopes or the use of shoring will be necessary to complete the below grade <br />construction. Based on our understanding of the planned development, shoring will be <br />necessary primarily along the east and south sides of the site. The existing retaining walls <br />that extend above the property on the east side of the site can be assessed for their <br />usefulness in contributing to the temporary shoring of the excavations. Adjacent to the alley <br />and existing brick building to the west and north of the site, respectively, no significant <br />lowering of site gredes is planned. Due to the close proximity of the development to the <br />existing building north of the site, we recommend locating the footing of the brick building andl <br />establishing its elevation. <br />Due to the close proximity of the existing two-story building north of the site, survey points <br />should be established along the foundation of the building to monitor movements during the <br />construction phase. A photo or video damage survey should be made on all adjacent <br />structures prior to the start of construction. We can assist you with the survey. <br />Recommendations for shoring aro presented in the "Shoring" section of the report. <br />This report has been prepared for the exclusive use of Cascasia Pacific Properties, Ltd. and <br />their representatives. The report was prepared for specific application to this project only and <br />in a manner consistent with that level of care and skill ordinarily exercised by other members <br />of the profession currently practicing under similar conditions in this area. No other warranty, <br />expressed or implied, is made. We recommend that this report, in its entirety, be included in <br />the project contract documents for the information of the contractor. <br />Site Preparation and General Earthwork <br />The proposed development areas of the site should be stripped and cleared of existing <br />structures, pavements, and surface vegetation. Existing utility pipes intended to be <br />abandoned should be plugged or removed. Once the site has been stripped, temporary <br />shoring, where necessary, can be installed, and the excavation to design subgrade elevations <br />can begin. <br />Esnh Consuhents, Inc. <br />