4225 HOYT AVE 2018 WESTERN WA MEDICAL GROUP Plans 2022-12-27
>
Address Records
>
HOYT AVE
>
4225
>
WESTERN WA MEDICAL GROUP
>
Plans
>
4225 HOYT AVE 2018 WESTERN WA MEDICAL GROUP Plans 2022-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 1:34:27 PM
Creation date
3/20/2019 8:54:24 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4225
Tenant Name
WESTERN WA MEDICAL GROUP
Permit
B1803-013
Year
2018
Notes
RETURN DENTAL OFFICE TO MEDICAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS DATE <br /> � <br /> WALL & FLOOR FINISHES IN RESTROOMS ' <br /> � <br /> COMPRESSION STRUT <br /> NOTE: LATERAL BRACING FOR INTERIOR PARTITIONS INSTALL C�12°o�� OC EA.DIRECTION <br /> AND SEISMIC BRACING FOR CEILING GRID MUST BE FOR EVERY 144 SQ. Ff. OF CEILING AREA <br /> SHEET VINYL FLOOR THAT EXTENOS <br /> PROVIDED PER APPLICABLE BUILDING CODES. VERIFY LOCAL CODE REQ'Ts. N <br /> UP (COVES) ONTO WALLS 5n CONTRACTOR SHALL PROVIDE DETAILED SHOP 12 GA. HANGER WIRE q � <br /> lYPiCAL 4'0' O.C. �, N <br /> 4' HT. PLASTIC LAM. DRAWING TO THE LOCAL BUILDING INSPECTOR ADJ. HANGER SIZE FOR BRACING WIRES TO BE ATT�D AT � � <br /> WAINSCOT; WALLS W/IN DETAILS FOR APPROVAL PRIOR TO FABRICATION OF SYSTEMS LOADING PER C E A MAXIMUM OF 45 DEGREES TO THE o <br /> PLANE OF THE CEILING & PARALLEL �i <br /> TO COMPONENTS INTERSECTING AT THE ,s2 � � cD <br /> 2' OF FRONT & SIDES � o <br /> BRACE LOCATION. BRACE WIRES TO <br /> OF TOILEfS MAIN RUNNER 4'0" O.C. °�' ��i � � � <br /> BE TAUT AND TIED BOTH ENDS W/A � �, o o CO <br /> CEILING TILES (FIRE GUARD IF REQUIRED) MiNiMUM 3 TicH-r w�uPs � q � � � <br /> � 1 . ARMSTRONG SECOND LOOK II, COLOR WHITE 12 GA. BRACE WIRES � •� o ° ^ . <br /> E X P O S E D T E E G R I D (T H R O U G H O U T) d � � a Q <br /> LIGHT FIXTURE SCHEDULE ENERGY <br /> � � � � <br /> � � � v � . <br /> �p�sp CEE A Recess Fluorescent 2'x4' 8 Operatory task <br /> GWB CEILINGS IN HC RESTROOM, X-RAY PROCESS, MECH 4 tube fixture; DuraTest lights <br /> (EXISTING GWB CEILINGS IN PRI. OFF, STAFF. PRIVATE LAV. TO REMAIN) VitaLite color corrected lamps EXEMPT <br /> SEISMIC BRACING FOR 1/2 x 1/2 silver paracube <br /> CEILING GRID w/plastic diffuser; ES <br /> CEILING HEIGHT 94" THROUGHOUT; 5�20w = 100 <br /> s�czoca, SOFFIT HEIGHT- 1 '0" RECEPTION; 10"- OPS CORRIDOR (VERIFYl B Recess mini can lights; <br /> , 6'X20GA STEEL � CONT. STEEI TRACK / \ / <br /> 3 Op.task lites <br /> JOISTS @24°oc clear alzac trim; MR 16 EXEMPT <br /> � ' <br /> C Existing 2x4 surface mount 3C�96w = 288 <br /> + + fluorescent fixture; diffuser <br /> + OP �P OP 2 OP 1 3 tube fixture; ES <br /> D Surface mount 1 x4 2 1 C� Mech. Rm. <br /> MECH EqU[� tube fluorescent fixture EXEMPT <br /> 5/8"GWB <br /> ,o•x2acn sr�� w�plastic diffuser; ES <br /> 5/8•cwa �o �24•oc E Existing recess 2'x4' 9�96w = 864 <br /> A A A A A q 3 tube fluorescent fixture, 2�Sterile <br /> BOTH SIDES INSUlA710N K parabolic diffuser; ES EXEMPT <br /> 1 � <br /> GW8 CEILINGS - TOIRAG — OP — OP OP PA � <br /> TO UNDERSIOE OF STRUCTURE � � F Wall vanity light; Forecast 2�34w = 68 <br /> MNN RUNNER T �R � (— —1 (— —I � —1 � I— —) � F3452-36E1 ; Satin Nickel <br /> ��,,,,�E�EE� — � � � SOF IT \ � ___._ --- 2 light fluor. T8 17w <br /> �HANGER WIRE _' <br /> ! r {/} 2 5"w x 5"h <br /> E _ E CORRIDOR E x E � x G Recess heavy duty exhaust fan; 5 fans <br /> HANGER WIRE + �_ _� -�' '�_ _' � � � <br /> MAIN RUNNER — Note: lignt proof fan in Dark Room <br /> CROSS FURRING + <br /> + Exist fan in Private Lav to remain <br /> E � <br /> � � � � H Surface mount fluorescent 1 �X-Ray Process <br /> + + \ ACOUSTICAL PANEL CEIIJNG /� TERIL H <br /> �"'A'� ^"�'� STAFF � I �y�E � fixture; 1 22w EXEMPT <br /> ATfACH MPJN RUNNER CHAIJNELS / � �84 . <br /> TO HANGER STUDS W/2 �10 E E ,� X—RAY <br /> SELf TAPPING SCREWS J o OF ICE {� PROCESS � _ <br /> 5/B• cwa C I � -_._ I Recess can light w/clear 3�18w - 54 <br /> RUNNER CHANNEL <br /> SOF�r I 1� alzac trim; 1 13w fiuorescent <br /> � � J J /I K K G J Undercabinet 4' fluorescent 7 task light <br /> PRIVATE � _ � E ' � � HCRR fixture w/diffuser EXEMPT <br /> � OFFICE � � � 3 [ � <br /> B�,-�o� oF—� , (— j � K Existing recess 2'x4� fluorescent 3C�?64w = 192 <br /> STRUCTURE <br /> � l PRIVATE �� � 2 tube fluorescent fixture, <br /> ,2" LEG AT � � �`/ � E � AR H TO e W/parabolic diffuser; ES � <br /> 2 1/2'X25GA METAL STUD STRUCTURE; ATTACH / z <br /> EXI TING FAN � I WA L NIC ES � L Dark Room "safe li ht�� 1 � W <br /> BRACING �4B" OC TO W/2 POWDER ORIVEN . <br /> STRUCTURE FASTENERS PER BRACE • F - <br /> LO ATION OF CE l SE ELEV S. � / g X—Ray Process � <br /> � FIRE EXTINGUISHER / � F (switched outlet at 72" EXEMPT W <br /> (RATING 2A 10 BC) � / I or red safe fixture) O <br /> � MOUNT SO THAT TOP � <br /> FINISHES 3' TO 5� SOFFIT �� .� 1 ARc TOP � � TOTAL WATTS 1566 � � <br /> ABOVE FINISHED FLOOR � _- — HEA ER AT ��/ I II _ <br /> � ENT Y TO IDS� \S / TOTAL ALLOWABLE WATI�AGE 1573 � � <br /> � SUSPENDED CEILJNG ECEPT N Ro �( 131 1 Square Feet @1 .2 watts W <br /> � � per square foot U 1- o <br /> \ \ � C!7 <br /> � °� <br /> B 1885 SF - 574 SF = 1311 SF 0 � � <br /> INSUU1710N ( Exempt Dental Task Areas: <br /> � �O <br /> Operatories, Pan, Sterile, X-Ray Process Q � �N <br /> 1 LAYER 5/8" <br /> GWB EA SIDE EXIT � Exempt Equipment Room z U >0O <br /> OF MET 5TUDS <br /> � � <br /> � � ��� <br /> POWDER DRIVEN � _� <br /> FASTENER 024• oc ENTER <br /> EXIT LIGHTING PER CODE EXIT � -� <br /> AIEf RUNNER TRACK W � N > <br /> � EMERGENCY LIGHTING PER CODE z � d-w <br /> 5EALANT <br /> � CONCREfE SLAB <br /> / <br /> STANDARD PARTRION FASTENERS & BRACING Date 12/3/03 <br /> sca.�e 1�4" = 1 '-0" <br /> Drawn SAY <br /> S�et # I D— _�3-__ . __ <br /> REFLECTED <br /> � <br /> �p� ��,�-��;� �iL,� CEILING PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.