Laserfiche WebLink
� <br /> — — � <br /> GENERAL ELECTRICAL NOTES: <br /> 1.THE ELECTRICAL WORK SHALL INCLUDE FURNISHING ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT, TOOLS, ELECTRICAL KEY KEYED N�TES. <br /> TRANSPORTATION, lNSURANCE AND PERFORM OPERATIONS REQUIRED TO CONSTRUCT AND INSTALL COMPLETE AND <br /> OPERATIVE ELECTRICAL SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWINGS. � DUPLEX RECEPTACLE.SEE ELEVATIONS FOR MOUNTING HEIGHTS(SPACING. O 2'-10"HIGH TRANSAGTION COUNTER W/ELECTRICAL 8 PAGK, GLEAN,JB FOR PHONE& DATA EXTEND <br /> 2.ALL MATERIAL FURNISHED AND ALL WORK INSTALLED SHALL COMPLY WITH THE LATEST ACTIVE OR ADOPTED EDITtONS � EXISTING WIRING RUNS AS NECESSARY TO NEW COUNTER CABINETS. <br /> OF THE NATIONAL ELECTRIC CODE, STATE OR IOCAL ELECTRICAL CODES,AND THE REQUIREMENTS OF THE UTILITY <br /> COMPANIES.WHERE CONFLICTS OCCUR, THE MORE STRINGENT OR THE CODE ENFORCED BY THE AUTHORITIES HAVING � QUAD RECEPTACLE.SEE ELEVATIONS FOR PRE-MOUNTED CABINET RECEPTACLE. O NOT USED. <br /> JURISDICTION SHALL APPLY. <br /> 3.WORK INTENDED, BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED OR NOT SHOWN SHALL BE FURNISHED AND O NEW PARTIAL HEIGHT WALL W/TEMPERED GLASS SNEEZE GUARD BY G.C. <br /> INSTALLED COMPLETE TO PERFORM REQUIRED FUNCTION. � BULKHEAD MOUNTED RECEPTACLE FOR LCD N MENU BOARD. 300 WATTS MAX(EACH) � <br /> 4. ELECTRICAL PLANS ARE DIAGRAMMATICAL. DO NOT SCALE. COORDINATE ACTUAL IOCATIONS OF ALL DEVICES AND O NEW GRAB-N-GQ REFRIGERATED MERCHANDISER&ELECTRICAL AS REQUIRED. <br /> ROUTING OF ALL RACEWAYS WITH ARCHITECT AND ALL TRADES PRIOR TO ANY ROUGH-IN. <br /> � DATA OUTLET O NEW RED FOCAL SOFFIT ELEMENT ABOVE BY G.C. <br /> 5.ALL MATERIALS SHALL BE NEW AND IN GOOD CONDITION. THE MATERIAL SHALL BE THE PRODUCT OF SUBSTANTIAL�Y ��� � � <br /> ESTABLISHED AND RECOGNiZED MANUFACTURERS. <br /> r NEW PIZZA TRACKER&ELECTRICAL/DATA AS REQUIRED.SEE ELEVATIONS FOR HEIGHTS/SPACING. <br /> 6. CONTRACTOR SHALL COORDINATE HIS WORK SO THAT IT DpES NOT INTERFERE WITH THE WORK OF ALL OTHER � TELEPHONE OUTLET V PROVIDE RECESSED RECEPTACLES <br /> TRADES . IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO SEE THAT THIS WORK IS INSTALLED IN A TIMELY MANNER. <br /> PLAN AND INSTALL ALL ELECTRICAL WORK IN SUCH A MANNER AS TO PREVENT OBSTRUCTIONS,AND KEEP OPENINGS AND <br /> PASSAGEWAYS CLEAR. CONSULT ALL CONTRACT DRAWWGS FOR CONDITIONS AFFECTING THIS WORK AND VERIFY O PROVIDE RECESSED RECE�P AC�LES.MOUNTED TO NEW BULKHEAD W/ELECTRICAU DATA AS REQUIRED. <br /> SPACES IN WNICH WORK WILL BE INSTALLED. NOTIFY ARCHITECT iMMEDIATELY OF POSSIBLE CONFLICTS .WHERE A RC H ITECT <br /> INTERFERENCE WITH STRUCTURAL, MECHANICAL OR OTHER FEATURES EXIST, OR WHERE JOB CONDITIONS REQUIRE <br /> REASONABLE CHANGES IN LOCATIONS AND ARRANGEMENT OF INDICATED EQUIPMENT,CONDUIT, OUTLETS OR WIRING. � TWO NEW ADDITIONAL ORDER TERMINALS.SEE ELEVATION FOR HEIGHTS/SPACING. PROViDE RECESSED -- -- --- --- - ---- - - <br /> CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT EXTRA COST TO OWNER. RECEPTACLES. �IO 7 SE WA SH IN GTO N ST. ' <br /> 7. CONTRRCTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND VISIT THE SITE PRIOR TQ SUBMlTTWG H!S BiD. HE SHALL SU ITE 3�O <br /> INCLUDE ALL WORK IN HIS BID DISCERNIBLE FROM REVIEW OF DOCUMENTS AND SITE VISIT. NO SUBSEQUENT O NEW CHILD STEP WITH NANDRAtL BY G.C. PO RTLA N D QR�72� <br /> ALLOWANCES WILL BE MADE FOR LACK OF REASONABLE REVIEW OF DOCUMENTS AND SITE VISIT. , <br /> � V.50 3.552.90 79 <br /> 8. CONTRACTOR SHALL LEAVE EACH ENTIRE ELECTRICAL SYSTEM IN PROPER WORKING ORDER AND SHALL REPLACE ANY ") NEW BENCH. F. 50 3.241.7�55 <br /> WORK OR MATERIAL PROVIDED BY HIM UNDER THIS CONTRACT WHICH DEVELOPS DEFECTS WITHIN(1)YEAR OF FINAL <br /> � ACCEPTANCE BY OWNER. � NEW HIGH-TOP BAR BY G.C. <br /> 9. CQNTRACTOR SHALL PROVIDE, MAINTAIN AND REMOVE AF7ER CONSTRUCTION IS COMPLETE, ADEQUATE TEMPORARY <br /> POWER AND LIGHTING SYSTEM. <br /> 10. LIGHTING FIXTURES SHALL BE FURNISHED COMPLETE WITH LAMPS, HANGERS AND INCIDENTALS. FIXTURES SHALL BE <br /> INDEPENDENTLY SUPP�RTED FROM THE STRUCTURE ABOVE.ALL LIGHTING FIXTURES, LAMPS AND LENSES SHALL BE �1 1 <br /> THOROUGHLY CLEANED PRIOR TO FINAL ACCEPTANCE. <br /> R€GiSTFA�� . <br /> 11.WIRWG DEVICES SHAL�BE SPECIFICATION GRADE WITH HIGH IMPACT NYLON COVER PLATES. COLOR OF DEVICES AND <br /> APlCFfiTE�t� <br /> COVER PLATES AS DIRECTED BY THE ARCHITECT,ACCEPTABLE MANUFACTURER'S ARE HUBBELL, P&S, GENERAL <br /> ELECTRIC AND COOPER INDUSTRIES. � �, <br /> `�----�.__ ._.. ason D. Gnich <br /> 12.WIRE SHALL BE'THHN'OR'XHHW COPPER, 90°C,600 VOL7S. SOLID SIZE 10 AND SMALLER, STRANDED SIZE 8 AND TATE O� WA5HINGTON <br /> LARGER.ALL FEEDERS AND BRANCH CIRCUITS SHALL HAVE A GREEN CODE SIZE EQUIPMENT GROIJND. MINIMUM SfZE <br /> WIRE#12 AWG. UNLESS OTHERWISE NOTED. <br /> 13.ALL INTERlOR WIRING SHALL BE IN EMT WITH STEEL, SET SCREW FITTINGS. EMT SHALL BE USED fN ALL BLOCK(CMU) <br /> WALLS.TYPE MC(METAL-CLAD)CABLE MAY BE USED ON THIS PROJECT SUBJECT TO MEETING ALL OF THE FOLLOWING <br /> CONDITIONS: <br /> A.THE LOCAL AU7HORITIES HAVING JURISDICTION MUST ALLOW THE USE OF MC CABLE. <br /> B.THE ARCHITEC7 AND OWNER MUST APPROVE OF THE USE OF MC CABLE. <br /> C.THE CABLE STRUCTURE AND INSTALLATION ARE IN ACCORDANCE WITH UL, NEC AND LOCAL CODE <br /> REQUIREMENTS. <br /> D.THE MC CABLE CONDUCTOR SIZE MEETS THE REQUIREMENTS OF THE CONSTRUCTION DRAWINGS AND NEC. THE <br /> MINIMUM WIRE SIZE SHALL BE#12 AWG. THHN OR THWN. <br /> E.THE MC CABLE MUST CONTAIN AN NEC SIZED GREEN GROUND CONDUCTOR FOR ALL CIRCUITS. <br /> F. RECORD DRAWiNGS(AS BUILT DRAWINGS)SHALL REFLECT THE USE AND ROUTING LOCATIONS OF THE MC CABLE. <br /> 14. CONTRACTOR SHALL COORDINATE AND MAKE FINAL CONNECTIONS FOR MECHANICAL EQUIPMENT. SIZE ALL <br /> FUSES/CIRCUIT BREAKERS PROTECTING MECHANICAL EQUIPMENT PER EQUIPMENT MANUFACTURER'S <br /> RECOMMENDATIONS. <br /> � � -- <br /> 15. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL WIRING, RACEWAYS, OUTLET AND JUNCTION BOXES, O � I <br /> MOTOR STARTERS, DISCONNECT AND CONTROLS FOR EQUIPMENT FURNtSHED UNDER OTHER SECTIONS, UNLESS NOTED z <br /> I <br /> OTHERWISE.VERIFY EQUIPMENT REQUIREMENTS WITH EQUIPMENT MANUFACTURER PRIOR 70 BID. � � � � <br /> 16. CONTRACTOR SHALL NOT INTERRUPT OR REMOVE ANY EXISTING CIRCUITS OR EQUIPMENT UNL.ESS NOTED 5 <br /> OTHERWISE ON PLANS.ANY DAMAGED OR D(SRUPTED CIRCUITS OR EQUIPMENT SHALL BE RESTORED TO LIKE NEW � ! ; 17 a 1 �a <br /> CONDITION AT NO ADDITIONAL COST TO OWNER. m � � � � I 8 <br /> 17.ALL PENETRATIONS OF FIRE-RESISTIVE FLOORS OR WALLS SHALL BE PR�TECTED BY MATERIAI�S AND INSTALLATION � O �'O � � <br /> THAT CONFORM TO UNDERWRITER'S LABORATORIES LISTINGS FOR'THROUGH-PENETRATION FIRE STOP SYSTEMS.'THE Q � i i <br /> CONTRACTOR SHALL SUBMIT TO THE ARCHITECT, SHOP DRAWING DETAILS, FURNISHED BY THE MANUFACTURER QF THE � O <br /> FIRE STOP MATERIAL,WHICH SHOW COMPLETE CONFORMANCE WITH THE UL. THE DRAWINGS SHALL SE SPECIFIC FOR � � <br /> EACH PENETRATION, WITH ALL VARIABLES DEFINED. Q CC-jO� j � <br /> �.. r � N o <br /> 18.THE CONTRACTOR SHALL CONFIRM AND VERIFY THE LOCATIONS OF ALL EXIT AND EMERGENCY LIGHTING WITH THE � i ('V <br /> ARCHITECT PRIOR TO ANY INSTALLATION. _ (� � � � � (� <br /> (.� � � � 7 � � O� <br /> 19. THE ELECTRICAL CONTRACTOR SHALL COORDINATE SYSTEM FURNITURE JUNCTION BOX LOCATIONS WITH THE — I I —n'' <br /> SUPPLIER AND MAKE ALL FINAL FLEXIBLE CONNECTIONS TO SAME. _ � j � ' ( rr - - ---_��----- - - � � �V Q <br /> 0 0 , 17� � I �; � � � � � <br /> � -� 11 7� I � „ . <br /> W 32 ' �� <br /> , ;, , 0 0 . <br /> r .�.._ <br /> W '_' � � � ' ABV. � � I ;� I � � � � <br /> � W � 7.0 ; cc—o2 ; , � ;; � � v � <br /> � z z ' i � ' i� ' N y- � > <br /> Ll..i V- � � ( � �� � � � W <br /> i i t � � �; � • • � <br /> °C 3 4 � � � i i �� i � � <br /> W � �� o � � <br /> �� <br /> m A3.0 0 7.0 � � 7� � � i '; � °° 0 � J <br /> o , REMODELED , , 32 � � ;; Z � -� <br /> I— z � � �� I �; � N � � v <br /> W � C U STO M E R � �_� 7 ; ABV. L � i '; i � •N � �, � <br /> ' U °- <br /> Q A R EA ' ; � ;; � � �, � � . <br /> ► , � ;� i N � � c� <br /> � ► ,� �– cr� �o <br /> N i i � �� � 0 � <br /> T`– i i 6 � ;i ( • —� � t–�– > (� U <br /> � i �� i 7.� I ;; I O �� � W z `d' <br /> - � �--!./ � �� �-- . <br /> 1'-4 1/2° � � � � ;� � � � � O c� <br /> I ��c r i I � I I � ._.., � L Q <br /> I I — — —__��_'__— — — —'- � � 1..1.� � O � <br /> I i <br /> 1 1/2"DIA BRUSHED 4 I �/ �` � I <br /> STAINLESS STEEL � � E/� J T I �1 G \ <br /> HANDRAILSECURED 5 � I � � ISSUED FOR PERMIT. <br /> RUBBER TILE TO FLOOR&PARTIAL � � P R 0 D U C T 0 �I <br /> HEIGHT DOUGH WALL ? � � � O�.n�. � Q <br /> - FLOORS AIR �•0 J I <br /> ' ' AR EA L O • <br /> N NOSING � � I <br /> T- (FG07) ALL EXPOSED AREA <br /> I I � <br /> O� OF STAIR TO BE CLAD � � <br /> N IN (MT-01) �O �-} j � \ � j �-� �-� �-� REV: DATE: DESCRIPTION: <br /> BACKSPLASH TO BE P-LAM [PL-04] N ' I / \ ' I ' ' I ' I <br /> ON 4"SUBSTRATE, TYP. N - , , <br /> � <br /> _ STAIR CONSTRUCTION � � i � i � � � � ; ; <br /> C O U N T E R T O B E P-L A M [P L-0 4] O T O B�3/4"P L Y W O O D 9 3 3 � � � � � � � � ' ' <br /> � - I I 1\ / I ; � ; I � <br /> ON 4"SUBSTRATE,TYP. P-LAM ON ,- TREADS&RISERS ON FN-OH ; ; � � / � I I I � � � <br /> I 2X WQOD STRINGERS I � -� \�L----------------�a � � � ____--------------� f <br /> ALL VISIBLE SURFACES INCLUDING CO , _ _____ ______________ <br /> � ��---�------------------------r c; t�------------------------------------------------�-% <br /> BACK OF COUNTER FACING WWDOW � <br /> 4" BRUSHED � SHEET NAME: <br /> G.._,_. <br /> COUNTER, STEEL POST&PLATES STAWLESS <br /> TO BE SECURED TO COUNTER WITH STEEL BASE 1 i_6n • <br /> (4) LAG BOLTS PER LEG <br /> 16'-0" AREA TO BE REMODELED EQUIPMENT PLAN <br /> 3"DIA STEEL POST POWERCOATED <br /> [PT-08] <br /> 3 HIGH TOP BAR SECTION 2 CHILD STEP SECTION � EQUIPMENT PLAN SHEET NUMBER: <br /> SCALE; 3" = 1'-0" SCALE: 1" = 1'-0" SCALE: 1/2" = 1'-0" A . O <br /> 3 <br /> � —" COPYRIGHT 201$ . <br />