My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1420 HEWITT AVE 2017 TOGGLES BOTTLE SHOP Plans 2022-12-27
>
Address Records
>
HEWITT AVE
>
1420
>
TOGGLES BOTTLE SHOP
>
Plans
>
1420 HEWITT AVE 2017 TOGGLES BOTTLE SHOP Plans 2022-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 3:41:45 PM
Creation date
3/20/2019 11:54:01 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1420
Tenant Name
TOGGLES BOTTLE SHOP
Permit
B1707-009
Year
2017
Notes
TI FOR NEW TENANT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> z <br /> 0 <br /> � <br /> � <br /> � <br /> � � <br /> � <br /> � ~ <br /> 1 10' -0" `� � <br /> A Q _ <br /> � � <br /> � <br /> � w <br /> w n� <br /> z .�u <br /> � w � <br /> z cn c�ri <br /> �, �, � <br /> � �— � o <br /> — — H 1-�-�1 O <br /> • • <br /> '-'_'j ''. I� � � � � � <br /> � I r-.a...,.......�e.4..e..._..._.>.m.......�..m._.��..._�,..._..�...�....��.--e � O <br /> �� ..� : I . � /�'� --... ; � .. '� '.... .� �J I � � � <br /> . � � • �� _.... I i .^ `` <br /> v 1 v <br /> � � <br /> ' .— 1 <br /> ^, <br /> - ��. ::;" " : �-- ' <br /> � , 1 �J �___.um __.____.._. .__�.___ _.___.__.,...�__._._ . � <br /> I �� . ' I 3 � ; _ — � — 7 18 q r r - <br /> � �� �/\ I � I � - - - - � ( ( ;� � . , r r <br /> � ; ; 4 I � � I � ��� �: � � z z � � <br /> O�� I �� ���� . � � <br /> � 2 � � i i ii �0 3 � i � r � a � <br /> I t06 t05 ( � 3 11 I I I � I �� �I I � o cr o cv <br /> ( � " I r !i <br /> i r - ' ll� = - _ = - J 10 - _ , .�__ � <br /> r a <br /> ,. <br /> , � . <br /> . <br /> _ _ _ _ -�i-�.- , <br /> �� � � <br /> � ^ <br /> — — — — — — — <br /> , . <br /> �X I �� . ��fi� I �� � � <br /> i ,� a = <br /> a� Q o <br /> ~ � —� -- -- I -� � � � <br /> � 10� � ,__. -_ �---� �-- _ ___._. �__� �__� � c^r, � � <br /> "._'_ I I I ` ` � "'d Q <br /> - - � � U 3 � <br /> � � <br /> ( I I ¢ 3 ¢ ❑ <br /> T � I �1��fi�Y ' Q ~ <br /> � aa � <br /> � y <br /> I i � � I- = = = = = = -1 ���� 1 I �� j �� <br /> ����� f 12 � i � - - - - -�� _ �02 _ �o� � i � <br /> o,os � ���� I � � __ _ -- - <br /> __._ ; I � � _, _� � � ' � <br /> 8 � - '; <br /> � �--�-- � � � � t o4 � � � rt__-j i i i i i i (�_ i � <br /> (- � � I j' ; � � �- - - - - -� � � � u 1 � <br /> 6 �- -- �„_,`, \ �____ ---�-_ - ___------- -- ` --}---�- ---_-_____.i�---i- - ___ �----i � _ _ _ _ _ _ � ' � � r- v <br /> 1 <br /> �� � �� ► � ; , , � '_ __ ,� , � o �-� <br /> I ! � �! N M <br /> �-, �- � � M�N / OM�N � 2 �z � � a ; __ <br /> � � 2 ; � 2 � � � � ! � -r � �� i Q � <br /> 16 � (_ i[�' �0 / ; ; ? —_. -- _ _ —> >,Q i m - <br /> 13 ! � � ' � ___� c� <br /> , - � ' <br /> � <br /> i � ' ' � <br /> , : ' ---- - -- ____.L�__--�____-----_ --------___ ----- ------ <br /> O � tN � <br /> _ ,__ �__ ------�.._ _ _ -__._ <br /> NN '-•N <br /> � <br /> N <br /> N W � <br /> n_u_n <br /> ��� �C�U I �1�f�l�lfi ���1�! <br /> R� + <br /> SGALE : 1 /4" = 1 ' -O" <br /> NORTH � <br /> �� <br /> ��U I �M�N�� ��#���U�� <br /> �1�5#� I 1�C�fi0N ��fi�T� ��l���Y �0�� � <br /> N0. QTY D�SGRIPTION MAKE MODEL <br /> �o. � I ��� I 1�� ��1���0� 1����� <br /> 1 1 WALK-iN-GOOLER BARGREEN ELLING501� GUSTOM 1 . OGGUPRNGY SENSOR GONTROLS SHALL BE INSTALLED TO GONTROL LIGHTS IN ALL AREAS AND GOMPLY WITH THE FOLLOWING: - <br /> 2 2 KEG RAGK GHANNEL R5R72 A. AUTOMATIGALLY TURN OFF LIGHTS WITHIN 30 MINUTES OF ALL OGGUPANTS LEAYING THE SPAGE. <br /> 3 2 SHELVING METRO MAX 5Q37�G3 a� BE MANUAL ON OR MANUALLY GONTROLLED TO AUTOMATIGALLY TURN THE LIGHTING ON TO NOT MORE THAN 50� POYVER. ( FULL AUTOMATIG-ON <br /> GONTROLS Ai�E <br /> 4 - TAP TOWER BY OWNER - PERMITTED IN PUBLIG GORRIDORS, STAIRWAYS, RESTROOMS, PRIMARY BUILDING ENTRA�tGES AND LOBBIES AND OTHER AREAS WHERE MANUAL ON <br /> 5 2 HAND SINK JOHN 8005 PBHS-W-1410-4D-X OPERATION WOULD PRESENT A LIFE SA�ETY OR SEGURITY OF THE BUILDING OGGUPANTS OR RDOM. <br /> 6 1 DISH MAGHINE ( LOW TEMP. GLA55 WASHER) AUTO-GHLOR U34 b. SHALL INGORPORATE A MANUAL GONTROL T� ALLOW OGGUPANTS TO TURN LIGHTS OFF. <br /> 7 1 GLA55 DRYING PAD GHOIGE 2' X 8' BAR MAT <br /> 8 1 3 GOMPARTMENT SINK .10HN B005 E338-1G1414T14-10T15-X 2. IN WAREHOUSE AREAS, LIGHTING IN AISLEWAYS AND OPEN AREAS SHALL BE GONTROLLED WITH OGGUPANT 5EN50R5 THAT AUTOMATIGALLY <br /> REDUGE THE LI�HTING LEVEL TD NOT LE55 THAN 50% WHEN THE AREAS ARE OGGUPIED. OGGUPANGY 5EN50R5 SHALL GONTROL LIGHTING IN EAGH <br /> q 1 WINE REFRIGERATOR THERMO ELEGTRIG AD-GDWRib-15R AISLEWAY INDEPENDENTLY AND SHALL NOT GONTROL LIGHTING IN THE AISLEWAY BEING GONTROLLED BY THE 5EN50R. <br /> 14 1 P05 BY OWNER - � <br /> 11 � GLA55 RINSER/ DRIP TRAY MIGROMATIG DP-820D-336-R 3. EAGH AREA OF THE BUILDING NOT GONTROLLED WITH OGGUPANGY 5EN50R5 SHALL BE PROVIDED WITH TIME SWITGH GONTROLS PER WSEG <br /> 12 1 MERGHANDISING GOOLER TRUE AIR GDM-72-HG-T5L01 REQUIREMENTS. <br /> 13 1 UTILITY SINK/ MOP SINK JOHN 8005 113184-X 4. SPAGES 12EQUIRED TO HAVE LIGHT REDUGTION GONTROLS SHALL HAYE A MANUAL GONTROL THAT ALLOWS OGGUPANTS TO i�EDUGE THE GONNEGTED <br /> 14 1 TRASH GAN/ REGYGL� ( UNDER GOUNTEF� ULINE H-5148BL LIGHTING LEVEL NOT LESS THAN 50� IN A UNIFORM ILLUMINATION PATTERN. NOTE: LIGHT REDUGTION GONTROLS ARE NOT REQUIRED IN DAYLIGHT <br /> 15 1 tARGE TRASH GAN RUBBERMADE H-1045GR ZONES WITH DAYLIGHT RESPONSIYE GONTROLS. <br /> 16 1 TRASH GaN - 42 GALLON GOMMERGIAL ZONE �i32101 <br /> 17 1 MERGHANDISING GOOLER TRUE AIR G-DM-4q-HG-TSLGI 5. MANUAL GONTROLS SHALL BE READILY AGGE55IBLE TO OGGUPANTS AND BE LOGATED WHERE THE GONTROLLED LIGHTS ARE VISIBLE. <br /> 18 1 GROWLER OSKAR BLUES 8000 SENIOR ELEG. SEAMER 6. DAYLIGHT RE5PON5IVE GONTROLS SHALL BE PRDYIDED IN ALL DAYLIGHT ZONES. _ <br /> A. LIGHTS IN PRIMARY AND SEGONDARY DAYLIGHT ZONES �"� <br /> SHALL BE GONTROLLED INDEPENDENTLY. O <br /> b . DAYLIGHT RE5PON5IYE GONTROLS SHALL BE � � <br /> GON�IGURED TO GOMPLETELY SHUT OFF ALL GONTROLLED 4 CI) <br /> LIGHTS IN THAT ZONE. <br /> c. LIGHTS iN DAYLIGHT ZONES FAGING DIFFERENT ~ v <br /> ORIENTATIONS ( I . E. , WITHIN 45 DEGREES OF DUE NORTH, <br /> � � z <br /> EAST 50UTH, WEST� SHAL.L BE GONTROLLED INDEPENDENTLY > � � a <br /> OF EAGH OTHER. � m a N t' <br /> d. A S I N G L E D A Y L I G H T G O N T R O L Z O N� S H A L L N O T E X G�D � t/� Q � � <br /> 2, 500 S. F. � � _ Q � - <br /> 7. DAYLIGHT RE5PON5IVE GONTROLS SHALL BE GON�IGURED TO AUTOMATIGALLY REDUGE THE POYVER OF GENERAL LIGHTING IN THE DAYLIGH7 ZONE Q � 3 � <br /> a� <br /> IN RE5PON5E TO AVAILABLE DAYLIGHT, WHILE MAINTAINING UNI�ORM iLLUMINATION LEYELS WITHIN THE SPAGE. Z � _ °�' w <br /> Q � � wmm <br /> 8. EXTERIOR LIGHTING (OTHER THAN EMERGENGY AND/OR LIFE SAFE'fl' RELATED LIGHTING) TH,4T I5 INTENDED TO BE AUTOMATIGALLY OFF � <br /> DURING DAYLI6HT HOURS SHALL BE PROVIDED WITH A GONTROL THAT AUTOMATIGALLY TURNS OFF THE LIGHTING A5 A FUNGTION 0� AVAiLABLE Drawing: <br /> DAYLIGHT. <br /> GONTRO ED FROM A SINGLE SWITGH OR AUTOMATIG GONTROL SHALL NOT EXGEED THAT WHIGH I5 A2 . � <br /> q . THE MAXIMUM LIGHTING POWER THAT MAY BE LL <br /> PROVIDED BY A 20 AMP GIRGUIT LOADED TO NOT MOizE THAN 80�. A MASTER GONTROL MAY BE INSTALLED PROYIDED THE INDIYIDUAL SWITGHES <br /> RETAIN THE GAPABILITY TO FUNGTION INDEPENDENTLY. GIRGUIT BREaKERS MAY NOT BE USED A 50LE MEANS OF SWITGHING. �obNU�: • <br /> 17c-3804 <br />
The URL can be used to link to this page
Your browser does not support the video tag.