Laserfiche WebLink
C D E E5 � � <br /> E� END <br /> OT - TEMP. SENSOR <br /> .� <br /> N SEE SHEET 1 M10-26 � <br /> __.._. _ - - <br /> - -- - -- -- -- -- -- -- -- - -- - -- -- <br /> ___ = SMH SMH � I o 24x24 4" P TED FILTER � v �; — �� — T _ <br /> -- �Wa s n A C C E S I B L E R O M O U T S I D E W� .�� THERMOSTAT <br /> 2�»� i � � � F e � ( �-Se n �,Y oY a-�----EXISTING TEMPERATURE 2 OF D A C ET `''� A � � - BAIANCING DAMPER <br /> � STORAGE sT cE �� �� SENSOR (AC 130) � <br /> 26 20 � � UP ( 46/20 < � �, m 34"� m 30"� 26"� 20"� �,Si �� CHOPS <br /> 89 � � <br /> � , � IST <br /> �__J �� IFTER m <br /> X� X�O BEAD <br /> �? � ? � Y ^ �Y i n » BLISTER <br /> �� `f' �v 20'� 20 � o� � 20 � Q� � , POWER ISLAf�D�22 <br /> � �� Ng � � '-'� � OP£RATOR A EA 5' WiDE �-� c� SD-220 <br /> 2 � ,���� � g FAKOUT �� @� �� � � ,� aaQo ^ ' aoQo 0 E OR AREA (5 ��Q VACUUM SY�� F GE ERA� �l OTES <br /> ,,,� D-325 2 S ATION �� X�o �� „ • � � � _ . o U � � 27`0 CFM `l <br /> 65 CFM � � .� > > Y 14 � ' w � U b D ' A ��. 24� ` � � <br /> � $°� �� ��� N � 18 � � o n �' �8"� �8"� �$"� M714 � 1� COOLING UNIT, FAN COIL, CAPACITY - 11500 BTUN, <br /> �o"� -325 "�° " �' _ � � STRATASYS HORIZON PRIN I STRATASYS H RIZ N PRI � � OUTLINE OF Q�S� v� AIR FLOW - 520 CFM, CHILLED WATER FLOW - 3.5 � <br /> �° /- 165 CF � 2 2 TUNNEL BELOW SANDER <br /> � f �, $ � o \ �� - 2 2 FLOOR GPM AT EWT = 45°F, 4-ROW COOLING COIL, BOTTOM <br /> � X 8 `, �o Q ELECT IC LiFf RELOCATED CHOP SAW RETURN, 115 VOLT SINGLE PHASE 3 TAP PSC <br /> n � � ^ p p T LE LIGHT <br /> �2 � N �4 � 2 � , � � � MOTOR, 24 VOLT CONTROLS CODE BCO2, CODE 24 <br /> SD-325 s� 25 �@N {o�� - V � � �xgs p�S�� POWER ISLAND/ � PIPING PACKAGE, 2-WAY 2-POSITION VALVE, <br /> 240 CFM � X'° ° „ W �, VACUUM SYSTEM M <br /> 30 CFM S H � g $ � _ _ � � SAN� <br /> �o"� 2 2 , - � - o � ¢ ¢ BC 2X-393728 ENVIRO-TEC MODE�/SIZE H�P 30 <br /> � , --RR-224 � � Q � � �, <br /> � F-- � n v� v> BAN RELOCATED <br /> � 600 CFM ] � a � w W �1 <br /> SD-323 1 2�� � 2 2 j�4"� 9 � �' °' _ � ��o � ��o ¢ �AW �TRIM LIGHT 2� DUST COLLECTOR: DONALDSON/TORIT DFE-2-8, TOP <br /> �,�f 435 CFM 1 g � ,_ a� ,_ � o� �� E��c ic u�- TAB�E EXPLOSION VENT, HOPPER AND LEGS, TBI-15, 25 HP <br /> 12 Y+ \ � � rnv �. mu <br /> o �P 8 / � T BLE � COLLECTOR MTD. BI FAN, 5000 CFM C� 12" TSP, HI <br /> o MQs �`' ' `�-� 22 �a � � RR 225 5 � �BXss s�-22o � EFFICIENCY SILENCER FOR FAN OUTLET. <br /> � OWDER � 14 � 2 Q34 cFM oO SD-220 VD � OWNER PROVIDED. <br /> .— � N ;:� 12"� 12"� 12"�= 12"� 2730 CFM 2730 CFM � <br /> AC X Z x `— v aso v � � � �-- <br /> ~ `° � ��� � °' � � 26� X W DUST COLLECTOR DUCT MATERIAL: 22 GAUGE <br /> W � 138 LaJ ''� '��- � ACCESS WSLE (3'WiDE)� Z�A ACCESS kiSLE (3� WI } z�A �i x 2 x <br /> �'-� SD-324 � °'� z 3 p a power 3 phose pawer <br /> = SD-316 o ELECT IC LIFT �W JW �' �'W v GALVANIZED STEE� "DONALDSON EASY DUCT" WITH <br /> w �o cFM 8„� 2 $„� � 3 9 485 CFM � � � t T SLE �m �¢ �Q v� w FULL E�ECTRICA� BONDING. <br /> 1 ( TU BLER (TYP 16) Q I ,�, W <br /> � x z� FlL R a I I �X96 w w w w � <br /> � 1 " X 10 �" �,�w= <br /> O <br /> z � � Q h A32 �9 C90 §1:E 'F31Y � <br /> � 12/10 Q ; 6 � � °° RELOCATED TEMPERATURE �,,, �,� ,,,, ��37 �� Q <br /> z¢ �' - _ _ SENSOR tA��3o> _ _ x; „n. � � �� _ x_ � � 5 � R E FE R E N C E D RAW I f� G S <br /> _ _ _ _ � �� _ _ BEAD BLASTER <br /> "� � S � 96" X 34" -— � <br /> z -- z <br /> 0 0 • <br /> � � A <br /> � , , � CONSTRU �TOf� NOTES <br /> � <br /> w w � PROVIDE 4"� DUCTS AND ASSOCIATED <br /> z A z APPURTENANCES TO 3D PRINTERS. <br /> _ _ <br /> Q 34� DOWN & TRANSITION .i 2�j PROVIDE NEW SUPPLY AIR DUCTWORK, <br /> � T O 3 0/3 0 F L A N G E D C O N N E C T I O pENSATE RETURN UNIT 22� � DIFFUSERS AND ASSOCIATED APPURTENANCES. <br /> AT F100R FOR CONTINUATIO� <br /> SEE PARTIAL PLAN ON SHEET M584 ) 3Cj PROVIDE NEW AC UNIT. DDC SYSTEM TO MONITOR . <br /> �I�b� l���dd �i���J 1��1dd �i���l l��i�b'd 34� �b� l��i�yd I STATUS AND ALARM. <br /> sa� ea�xar sasxot <br /> � 1����� 4�' PROVIDE NEW 60/24 SCREENED RETURN INLET. <br /> _ _ 16 10 SR-249 16/7 � � <br /> 500 CFM Ac-�2� 500 CFM 500 CFM s � PROVIDE CONICAL SADDLE TAP PER SMACNA FIG. 3-5 <br /> SUPPLY AIR <br /> TYP 16 . <br /> � ❑ � DESK PCTABLE MWS X � COAT <br /> 30X60 30X60 �x�p � � <br /> 6�j PROVIDE NEW COOLING ONLY VAV BOX. <br /> � I � <br /> _ � 7�'- MONITOR AND ALARM TO DDC SYSTEM. <br /> p <br /> � <br /> � � 0 8` PROVIDE 120 CFM ABOVE CEILING GRID TO PRESSURIZE <br /> Y o m <br /> � � w � THE PLENUM SPACE. PROVIDE BIRDSCREEN AT END OF <br /> � � r <br /> � <br /> � � � � g � � � q <br /> " 8 � DUCT. <br /> � � z "' `� `� Y o sw sw sw sw sw 9�'j SEAL ALL PENETRATIONS OF DUCTS, PIPES, CONDUITS, <br /> N � = osxar X X o9xoc a�xas X � � <br /> J sMW o o SMw SMW o � r Q. AC AND OPENINGS AIRTIGHT ABOVE FULL HEIGHT WALL. <br /> — — — — � — — — — �- — — 5 01 <br /> w � � �o��� �ocK� 530 136 <br /> � CFM <br /> X = SR 6 � W SR 246 SR 246 o Q p � <br /> � — — — — — — — - - — 5 <br /> �— -- -- -- — — -- — -- -- — — -- -- <br /> MATCH LINE - FOR CONTINUATION SEE SHEET 1 M 10-36 � <br /> PARTIA� P �A�l � EW <br /> SGALE: 1/8"=1 '-0" <br /> DD CC C G L Q S. <br /> `° 7 8 10, <br /> ID <br /> � 10 11 12 13 14 <br /> � <br /> 9 <br /> � 15 16 17 18 19 <br /> � $ . <br /> N 20 21 22 23 24 <br /> 7 <br /> 25 26 27 2$ 29 <br /> 6 <br /> 30 31 32 33 34 <br /> 5 <br /> 35 36 37 38 39 <br /> 4 <br /> 40 41 42 43 44 <br /> 3 <br /> •• •• 45 46 47 48 49 <br /> � � . <br /> 50 51 52 53 54 <br /> � <br /> GROUP 55 <br /> 600 Stewart St., Ste 1400 K EYP �A�l <br /> Seattle, Washington 98101 � <br /> PHASE 1 IFC Tel Zo6.267.1700 �CALE: NONE <br /> �9.30. � 6 Fax 206.267.1701 8' 4' 0 4' 8' 16' <br /> SAZAN # 500-1666 <br /> SCALE: 1/8"=1 '-0" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBO� DATE ' <br /> — 767 TUBS & FRAMES 96206518 GMH A 04.21.97 <br /> THIS DESIGN AND/OR CNECKED HVAC DUCTWORK PLAN - FIRST FLOOR W2572915 A o9.30.� 6 <br /> SPECIFICATION IS APPROVED SHEET <br /> � ENGINEER TITLE IRC - WBS 2.2.3.4.2 ADDITIVE MANUFACTURING 1 M 10�� 1 <br /> — CEILINGS 1 96206524 JSM 09.11.97 �0�,�� APPROVED BY DEPT. DATE <br /> — IRC OFFICES 52378101 MJP DH/FB 01.31.06 CHECKED <br /> — ELEVATOR MDERNIZATION 53411805 GBK DH/FB 06.30.06 APPROVED B U I L D I N G 40-056 �oa N0. COMP N0. <br /> A IRC — WBS 2.2.3.4.2 ADDITIVE MANUFACTURING W2572915 SAZAN/GB 09.30.16 APPROVED MECHANICAL MASTER COL C-G/5-6 EVERETT, 1/r/A °wc r,o. 40-056-1 M10-31 <br />