3003 W CASINO RD 2018 BLDG 40-56 Plans 2022-11-23 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-56
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-56 Plans 2022-11-23 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:55:28 PM
Creation date
3/20/2019 2:37:21 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-56
Permit
B1610-029
Year
2018
Notes
TI TO DEMO OFFICE SPACE AND INSTALL ADDITIVE MFG AREA
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f _ _ __ <br /> C D � E � � � <br /> EGEND <br /> FOR GENERAL NOTES AND LEGEND SEE DRAWING 1 M260—G1 <br /> ON SEE SHEET 1 M260-26 <br /> - - - - - -� - - 1� - -� - - - - 6 . <br /> , ,,, <br /> � 1106 <br /> 3 <br /> � BREAKOUT 1 QC � °° °° <br /> f 11 G6 1 6 � � ARTITIONS 1 P 2SF 5MB � <br /> � � I � C� <br /> SYSTEM #8 1 3 <br /> � <br /> 2 2 2 � <br /> 12C6 13C6 14C6 ] <br /> I BOP=10'-4" AFF I ' <br /> o I I <br /> �, A � <br /> � � <br /> E � 1 3 N <br /> � FFF � <br /> w 6 11D6 W . <br /> � OFFICE/BREAK AREA � � <br /> � STORAGE 13C� I � � � � <br /> z 1386 � z <br /> 0 3 0 <br /> Q c <br /> � � �\ <br /> z - - - - - - - - - - - - - - - 505 <br /> z z <br /> � � 3 � � � <br /> � M675 <br /> � � . <br /> � � 10" �p � 10" `D � <br /> � � NEW 10" CONNECTION INTO 12" UNDERGROUND � STUB OFF OF WET SYSTEM i <br /> z MAIN UTILIZING RESTRAINED JOINTS. THIS SHALL AHU BARREL oUPRIGHT HEAD, 48'Y I z <br /> _, BE A FUTURE CONNECTION POINT FOR THE 222 LENGTH MINIMUM TO PROVIDE ANU J <br /> � NEW 10" PERMANENT FIRE LINE IN TUNNEL �— SPRINKLER PROTECTION FOR 222 � I v <br /> Q NEW 10"PIPE RISE TO 2'-0 CENTERLINE M680 � LOCATED ON ROOF. a R E F E R E�1 C E D RAW I �l G S <br /> � BELOW GRADE, UTILIZING GRAVITY THRUST ( � <br /> BLOCK SIMILAR TO PIV WSTALLATION � 5 UPPLIED FROM HRU �3 INSTA�L 165 DEGREE, STANDARD ORIFICE, <br /> ( 1" 1° ���� 1�" 1�" 2" 1�" 14" 1" 1" M676 STANDARD RESPONSE, FUSIBLELINK, <br /> { OCATEQ NEAR COL. D-5.1 <br /> 1 BYPASS VALVE AT THIS I I <br /> o SECTIONAL CONTROL VA�VE SPRINKLER GUARD, 2'-0" ABOVE LEVATOR . <br /> - � � � `� oO oO oO oO 11 E PIT FLOOR ON A SEPARATE CONTROL VALVE 14F5 I <br /> � FROM SV56 16 8„ 1 5. /� <br /> O I /-1 <br /> � � � � a N M680 N N � , CONSTRUCTI0 �1 �IOTES <br /> cfl I � I <br /> �o o � � � �, � � N N ELEVATOR 1 .- PROVIDE WET PIPE FIRE PROTECTION ABOVE AND <br /> � N 14F5 BELOW LAY—IN CEILINGS TO MATCH NEW ROOM <br /> � � J I LAYOUTS. PROVIDE NEW SPRINKLER HEADS: K-8 <br /> REMOVE EXISTING 8" PIPE AFTER —� NEW 4X1 VIC MECH. TEE � ACTO FLOOR SPACE STANDARD RESPONSE. <br /> � TEMP 10" LOOP AND 8'� SPRINKLER O 920 TIE EXISTING ENVIRONMENT L 11 F5 ( <br /> CONNECTIONS ARE IN SERVICE. BOOTH INTO EXISTING OVERHEAD SYSTEM <br /> BOND F�OOR °° � 2 '` PROVIDE NEW WET PIPE FIRE PROTECTION TO MATCH <br /> UTILIZE RODS A M67S „ _ I NEW ROOM LAYOUTS. SPRINKLER HEADS: K-8 <br /> FITTINGS TO ACHEIVE A 8 DN TO SV56 18 TEE OFF STANDARD RESPONSE. <br /> RESTRAINED JOINT OF RISER TO FEED NEW CORRIDOR a, <br /> � <br /> �o"x�o"xs" TE COMPLEfE � M675 w � RESTORE FP BRANCH PIPING T� EXISTING FP MAINS. <br /> � WITA��g;'gUG �ERFLY VALVU � � ' _ � x x _ _ _ 1 TB�UTE ABOVE NEW PRINTING EQUIPMENT AT HEIGHT <br /> �o" `� �o" U, �0 10 10 VATOR EQUIP. RM. � ° I <br /> [ � "' J o o � 13F5 <br /> — — — — " — — — _ — — �— ,,.,� — � <br /> MATCH LINE — FOR CONTfNUATION SEE SHEET 1 M260-36 <br /> ` PARTIA� P LAN � EW � I <br /> SCALE: 1/8"=1 '-0" I v <br /> DD CC C G L Q S, <br /> `° 7 10, <br /> � 10 <br /> � 10 11 12 13 14 <br /> 9 <br /> � 15 16 17 18 19 <br /> � 8 <br /> N 20 21 22 23 24 • <br /> 7 <br /> 25 26 27 28 29 <br /> s <br /> 30 31 32 33 34 <br /> 5 <br /> 35 36 37 38 39 <br /> 4 <br /> 40 41 42 43 44 <br /> f 3 <br /> .. .a 45 46 47 48 49 <br /> 2 <br /> 50 51 52 53 54 <br /> � <br /> GROUP 55 � <br /> 600 Stewart St., Ste 1400 K EYP �AN <br /> Seattle, Washington 98101 � <br /> PHASE 1 IFC Tel 206.267.1700 SCALE: NONE <br /> , t , , , <br /> �9.3�. � 6 Fax 206.267.1701 8 4 0 4 8 16 <br /> SAZAN # 500-1666 <br /> SCALE: 1/8"=1 '-0" � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTIT�E CURRENT REVISION SYMBOL DATE � <br /> f N <br /> { A IRC - WBS 2.2.3.4.2 ADDITIVE MANUFACTURING W2572915 SAZAN 09.30.16 THIS DESIGN AND/OR CHECKED FIRE PROTECTION PLAN - FIRST FLOOR W2572915 09.30.16 .;� <br /> SPECIFICATION IS APPROVED SHEET � <br /> BOE,��� APPROVED BY DEPT. DATE G N ER TITLE IRC — WBS 2.2.3.4.2 ADDITIVE MANUFACTURING 1 �260 31 0 <br /> CHECKED o <br /> APPROVED 6 U I L D I N G 40�0�� JOB N0. COMP N0. o <br /> a <br /> � <br /> APPROVED ELECTRICAL MASTER COL. C—G/5-6 EVERETT, Wq °wc No. 40-056-1 M260-31 <br /> en nFa ����an n�eir <br />