Laserfiche WebLink
SYSTEM DESIGNATIONS EQUIPMENTf DEVICES ABBREVIATIONS <br /> $ SINGLE POLE TOGGLE SWITCH os CEILING MOUNTED OCCUPANCY SENSOR A AMP LGTN LENGTH ' <br /> HASH MARKS INDICATE THE QUANTITY OF CONDUCTORS AA AMBIENT AIR LST 1�1BOR SAVING TANDEM G E�l ERA� �l OTES <br /> (�12 WIRE UNLESS OTHERWISE NOTED). IF UNMARKED $3 THREE-WAY TOGGLE SWITCH PP LIGHTING TRANSFORMER RELAY POWER RACK A/C AIR C�NDITIONING LT LIGHT <br /> INSTALL 2�12 IN 1/2"CONDUIT � � AC ALTERNATING CURRENT LG LONG 1 . ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER TO <br /> PHASE CONDUCTORS $K KEY SWITCH AC-X AIR CONDITIONING UNIT - X MA MILLI AMP ARCHITECTURAL, STRUCTURAL, MECHANICAL AND HVAC DRAWINGS FOR <br /> NEUTRAL CONDUCTOR IF REQUIRED $4 ECOSYSTEM 4-BUTTON WALL STATION, AF AMP FRAME MAG MAGNETIC GUIDANCE ON DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM <br /> GROUND CONDUCTOR(IF REQUIRED) $�� SWITCH FOR �OW-VOLTAGE SWITCHING SYSTEM LUTRON MODEL � CC-4BRL-WN <br /> es ECOSYSTEM DIGITAL BUS SUPPLY, A.F.F. ABOVE FINISHED FLOOR MAINT MAINTENANCE FINISHES, STRUCTURAL AND ARCNITECTURAL DETAILS, LOCATION OF <br /> 3V34-1V-6A/7,s,�� ANU-X AIR HANDLING UNIT - X MCC MOTOR CONTROL CENTER DUCTS, PIPES, STRUCTURAL STEEL OR OTHER SYSTEMS. INSTALL <br /> 3/4"c,3#a PANE� HOME-RUN $���2� ,q DINOTED OHN RAWING. (��LO�)VO D CATESWTWO ES LUTRON MODEL � CS-1 L-WM AT AMP TRIP MFG MANUFACTURER ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH, NEW/EXISTING, PIPE, <br /> PANEL/CIRCUIT � A W G A M E R I C A N W I R E G A U G E M A X M A X I M U M S T R U C T U R A L S T E E L O R O T H E R A R C H I T E C T U R A L F E A T U R E S. L O C A T E <br /> CONDUIT/CONDUCTORS SWITCHES AT TNIS LOCATION) RECEPTACLES AMP AMPERE MECH MECHANICAL LIGHTING SYMMETRICALLY IN PROPER RELATION TO FINISHED AREAS <br /> CONDUIT RUN EXPOSED, ALL CONDUITS 1/2" UNLESS $o� LIGHTING SWITCH WITH OCCUPANCY SENSOR � FOUR PLEX DROP RECEPTACLE APPROX APPROXIMATE MEZZ MEZZANINE EXCEPT WHERE DIMENSIONED ON THE DRAWINGS OR LOCATED ON � <br /> OTHERWISE REQUIRED OR NOTED ARCH ARCHITECT OR ARCHITECTURAL MIN MINIMUM REFLECTED CEILING PLANS. <br /> ------- CONDUIT RUN CONCEALED IN WALLS, ABOVE CEILING, IN FLOOR $M MOTOR RATED SWITCH, 120V, 15A, 1� � DUPLEX DROP RECEPTACLE AUTO AUTOMATIC MG MOTOR-GENERATOR <br /> SLAB OR UNDERGROUND • • PUSHBUTfON STATION AUX AUXI�IARY MISC MISCELLANEOUS 2. PROVIDE ADDITIONAL SUPPORTS FOR �IGHTING FIXTURES, SWITCHES, <br /> DUPLEX,15A,120V,1�,2P,3W, PARALLEL BLADE BOT BOTTOM MTD MOUNTED STARTERS, RACEWAYS AND OTHER ELECTRICAL EQUIPMENT WHERE THE <br /> T TELEPHONE, 3/4" MINIMUM CONDUIT ONLY, UNLESS SIZED OTHERWISE � GROUNDED. BLDG BUILDING N NEUTRAL BUILDING STRUCTURE IS NOT SUITABLE FOR DIRECT MOUNTING. <br /> � MANUA� MOTOR STARTER WITH OVERLOADS AND PILOT LIGHT °C DEGREE CENTIGRADE NEC NATIONAL ELECTRIC CODE <br /> E EMERGENCY CIRCUIT FOUR PI.EX-2 DUPLEX 15A,1�,2P,3W <br /> � MAGNETIC MOTOR STARTER � PARALLEL BLADE GROUNDED. CAB GABINET NC NORMALLY CLOSED 3. SYMBOLS IN THE LEGENDS ARE APPLICABLE GENERALLY. FOR EXACT <br /> FA FIRE ALARM CIRCUIT CAT CATALOG NIC NOT IN CONTRACT REQUIREMENTS REFER TO THE SCHEDULES, LAYOUTS, DETAILS AND <br /> PA PAGING CONDUIT WITN WIRE AS NOTED � COMBINATION STARTER, CIRCUIT BREAKER TYPE, 30 SIN�LE, 30A, 480V, 3�, 4 POLE, WITH CB CIRCUIT BREAKER NO NORMALLY OPEN SPECIFICATIONS SINCE THE APPEARANCE OF A PARTICULAR SYMBOL IN <br /> 30A UNLESS NOTED OTHERWISE � BACK BOX, GROUND THRU EXTRA POLE AND SHELL. CLG CEILING NS NEUTRAL SENSOR THE LEGEND DOES NOT NECESSARILY IMPLY TNAT THE ITEM IS INCLUDED <br /> c COPPER GROUND WIRE, SIZE AS NOTED CTR CENTER NTS NOT TO SCALE IN THE CONTRACT. � <br /> �► ENCLOSED CIRCUIT BREAKER SIZE AS NOTED �2o DUPLEX,20A,120V,1�,2P,3W, PARALLEL BLADE CHWR CHILLED WATER RETURN No. OR � NUMBER <br /> �v LOW VOLTAGE CONDUIT/WIRE ON DRAWING GROUNDED CHWS CHILLED WATER SUPPLY OC ON CENTER 4. MOUNT GROUPED DEVICES IN A SINGLE CONTINUOUS GANG BOX. USE <br /> 3/4" MIN. W1TH CABLE AS INDICATED UNLESS SIZED �-'-' DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, CKT CIRCUIT OD OUTSIDE DIAMETER PARTITIONS WHERE VO�TAGE BETWEEN EXPOSED LIVE PARTS OF <br /> Fo FIBER OPTIC, , , <br /> OTHERWISE. NO CONDULET FITTINGS IN FIBER OPTIC RUNS ALLOWED. 30/20 20=FUSE RATING � Ic DUPLEX,15A,120V,1�,2P,3W, PARALLEL BLADE COAX COAXIAL P POLE ADJACENT SWITCHES MAY EXCEED 300 VOLTS. <br /> WITH ISOLATED GROUND, ORANGE COL COLUMN PA PUB�IC ADDRESS <br /> c COMMUNICATIONS CIRCUIT �, DISCONNECT SWITCH, NON-FUSED, 30A C CONDUIT PNL PANEL 5. VERIFY CEI�ING SUSPENSION SYSTEMS IN THE VARIOUS AREAS AND <br /> UNLESS NOTED OTHERWISE C.O. CONDUIT ONLY � PERCENT <br /> 20 FOUR PLEX-2 DUPLEX 20A,1�,2P,3W ° PROVIDE THE PROPER MOUNTING ACCESSORIES, TRIMS, ETC. TO SUIT THE <br /> CONDUIT TURNEQ UP � � CONT CONTINUE PERP PERPENDICULAR PARTICULAR AREA. <br /> Mc MOTOR CONTROLLER PARALLEL BLADE GROUNDED. CU COPPER � OR PH PHASE <br /> � CONDUIT TURNED DOWN CT CURRENT TRANSFORMER PVC PO�YVINYL CHLORIDE <br /> � CAPACITOR 20 6. IQENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN <br /> 1A CONDUIT IDENTIFICATION (� SINGLE, 20A, 120V, 1�, 2P, 3W DC DIRECT CURRENT PWR POWER ACCORDANCE WITH SPECIFICATION SECTION 26 05 53, ELECTRICAL ' <br /> STRAIGHT BLADE, GROUNDED DED DEDICATED CIRCUIT PF POWER FACTOR IDENTIFICATION AND 26 24 16, PANELBOARDS. <br /> CABLE TRAY, SIZE AS NOTED ON THE DRAWINGS T❑ TRANSFORMER, SIZE AND TYPE AS NOTED DEG DEGREE PE PRESSURE ELECTRIC <br /> 30 DET DETAIL PB PUSHBUTi�ON 7. CONDUITS WHICH ARE EXPOSEQ ON WALL SURFACES SHALL BE <br /> �V�J-' FLEXIB�E CONDUIT, 1/2" UNLESS NOTED OTHERWISE � MOTOR, 12�V,1�, SIZE AS NOTED C� SINGLE, 30A, 120V, 1 �, 2P, 3W DIAM DIAMETER PR PAIR <br /> STRAIGHT BLADE, GROUNDED ARRANGED SUCH AS TO MINIMIZE ROUTING BETWEEN 2'-0" AFF AND <br /> DISC DISCONNECT PT POTENTIAL TRANSFORMER g'_0" AFF. CONDUITS WNICH MUST ENTER THIS SPACE TO FEED OUTLETS <br /> �,F�' PREWIRED FLEXIBLE CONDUIT PROVIDED WITH LIGHT FIXTURE TYPE R, �o MOTOR, 208V, 3�, SIZE AS NOTED DPDT DOUBLE PO�E DOUBLE TNROW QTY QUANTITY <br /> R-2, S AND S-2 AS LST (IABOR SAVING TANDEM) �30 SINGLE, 30A, 208V, 1 �, 2P, 3W DPST DOUBLE POLE SINGLE TNROW RECP RECEPTACLE OR EQUIPMENT SHALL BE COMBINED IN MULTIPLE RUNS WITH COMMON <br /> " " CONDUIT TO BE REMOVED � MOTOR, 460V, 3�, SIZE AS NOTED STRAIGHT BLADE, GROUNDED DN DOWN REF REFERENCE SUPPORT. <br /> EQUIPMENT TO BE REMOVED (EG. PANELBOARD) �O JUNCTION BOX, FIELD SIZED OR AS NOTED 20 (jG DR SWING REV� D REVISIONp 8. USE OF EMT CONDUIT FOR POWER, LOW VOLTAGE POWER, AND SYSTEM <br /> � �� SINGLE, 20A, 12�/208V, 1�, 3P, 4W, POLARIZED, <br /> � JUNCTION BOX, SQUARE 4 � STRAIGHT BLADE, GROUNDED EA EACH RGS RIGID GALVANIZED STEE� CABLE SHALL BE ALLOWED IN OFFICE SPACES, OFFICE PASSAGE WAY, <br /> (E) EXISTING ELECT ELECTRIC RM ROOM STOREROOMS, DATA CENTER ROOM, WORK ROOM, CONFERENCE ROOM <br /> � GROUNDING PIGTAIL 60 EMT ELECTRICAL METALLIC TUBING SECT SECTION AND PENTHOUSE SPACES. <br /> PB PULLBOX, FIE�D SIZED OR AS NOTED � SINGLE, 60A, 120/208V, 1�, 3P, 4W, POLARIZED, EMER EMERGENCY SHT SHEET <br /> STRAIGHT BLADE, GROUNDED ENGR ENGINEER SIM SIMILAR 9. USE OF GALVANIZED ELECTRICAL CONDUIT, JUNCTION BOXES AND <br /> Je JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTED EQUIP EQUIPMENT SPDT SINGLE POLE DOUBLE THROW SUPPORTING DEVICES SNALL BE ACCEPTABLE FOR INSTALlATION ON THE <br /> DISTRIBUTION " 20 2P 3W STRAIGHT BLADE, ETC ETCETERA SPST SINGLE POLE SINGLE THROW BUILDING EXTERIOR. HOWEVER, ALL GALVANIZED ELECTRICAL SYSTEM <br /> I� TELEPHONE OUTLET, WALL MOUNTED 12 AFF OR AS NOTED �cFci DUPLEX, 20A, 120V, 1�, , , SPECIFICATION <br /> GROUND FAULT CIRCUIT INTERRUPTING. EWC ELECTRIC WATER COOLER SPEC COMPONENTS LOCATED ON THE BUILDING EXTERIOR SNAL� BE PAINTED <br /> � PANELBOARD, 480V, 3�, 3W, PANELBOARD b DATA OUTLET, WALL MOUNTED 12" AFF OR AS NOTED EXIST EXISTING ST SHUNT TRIP WITH THE SAME FINISH AS APPLIED TO THE BUILDING EXTERIOR. <br /> �� DATA OUTLET, DROP RECEPTAC�E EXTR EXTERIOR SUB SUBSTATION <br /> � PANELBOARD, 480Y/277V, 3�, 4W, PANELBOARD, � FLOOR MOUNTED EXP EXPLOSION PROOF SUSP SUSPEND 10. NO PRODUCTS OR MATERIAL CONTAINING ASBESTOS OR SILICONE SHALL <br /> � SURFACE MOUNTED, FLUSH MOUNTED � PUSHBUTTON STATION, TYPE AS NOTED FOUR PLEX-2 DUPLEX 15A,1�,2P,3W FA FORCED AIR SW SWITCH BE USED IN THIS FACILITY. <br /> � PANELBOARD, 208Y/120V, 3�, 4W, OR 3�, 5W PANELBOARD O THERMOSTAT PARALLEL BLADE GROUNDED. FDR FEEDER SYS SYSTEM <br /> � SURFACE MOUNTED, FLUSH MOUNTED FIXT FIXTURE T TERMINAL 11 . ALL ELECTRICAL EQUIPMENT SHALL BE APPROVED FOR USE BY OWNER <br /> CO CONTACTOR, TYPE AS NOTED �3o FLOOR MOUNTED FLEX FLEXIBLE TEL TELEPHONE PRIOR TO INSTALLATION. EQUIPMENT DATA SHAL� BE SUBMITTEQ AS <br /> Mcc MOTOR CONTROL CENTER cP CONTROL PANEL SINGLE, 30A, 208V, 1�, 2P, 3W FLR FLOOR TR TRIP RE�AY DIRECTED BY OWNER. <br /> � REL�,Y TWISTLOCK, GROUNDED FLUOR FLUORESCENT T'STAT TNERMOSTAT <br /> FT FOOT XFMR TRANSFORMER 12. ALL ELECTRICAL EQUIPMENT ANQ MATERIA�S SHALL BE APPROVED BY <br /> o SPECIAL PANEL AS NOTED � INDICATES WALL MOUNTING 2� SURFACE METAL RACEWAY WITH ROUGH-IN BOX AND FURN FURNISH TYP TYPICAL UNDERWRITERS LABORATORIES INC. {UL), OR A TESTING LABORATORY <br /> � RECEPTAC�ES AS SHOWN ON PLAN GE GENERAL ELECTRIC UH UNIT HEATER APPROVED BY THE AUTHORIT`( NAVING JURISDICTION, FOR THE PURPOSE <br /> � TELEPHONE AND DATA/POWER POLE GEN GENERATOR UG UNDERGROUND FOR WNICH THEY ARE USED AND SHALL BEAR THEIR �ABE�. <br /> � SYSTEMS FURNITURE DUPLEX REGEPTACLE GF GROUND FAULT UON UNLESS OTHERWISE NOTED <br /> � COMBINATION FLUSH FLOOR BOX WITH GFCI GROUND FAULT CIRCUIT INTERRUPTER VERT VERTICAL 13. AL� ELECTRICAL EQUIPMENT AND RACEWAY SHALL BE <br /> SINGLE LINE DIAGRAM FOUR NEMA 5-15R OUTLETS GRN GREEN V VOLT VAULT <br /> � COMBINATION FLUSN FLOOR POKE-THRU WITH � POWERPOLE GND GROUND WP WEATHERPROOF SUPPORTED/ANCHORED/BRACED TO MEET ALL IMPOSED GRAVITY, WIND <br /> FOUR NEMA 5-15R OUT�ETS HTR HEATER WH WATER HEATER AND/OR SEISMIC FORCES IN ACCORDANCE WITH THE REQUIREMENTS OF <br /> ����� CIRCUIT BREAKER, AIR, DRAW OUT HGT HEIGHT W Wq-�- THE 2006 INTERNATIONAL BUILDING CODE. SEE STRUCTURAL DRAWINGS <br /> AUXILIARY SYSTEMS HID HIGH INTENSITY DISCHARGE W� WITH FOR SITE SPECIFIC WIND/SEISMIC DESIGN CRITERIA. SUPPORT SYSTEMS <br /> � FUSE LIGHTING HZ HERTZ W/0 WITH OUT ARE NOT PROVIDED AS PART OF THESE ENGINEERING DRAWINGS, THE <br /> FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, $v P.A. SYSTEM ATTENUATOR, WALL MOUNTED, HPS HIGH PRESSURE SODIUM Z IMPEDANCE CONTRACTOR SHALL BE RESPONSIBLE FOR THIS DESIGN AND SHALL <br /> A SHT. EOb QUANTITY AND RATING OF IAMPS �fl WATT RATING HV HIGH VOLTAGE PROVIDE MANUFACTURER S DATA OR CALCULATIONS PREPARED BY A <br /> 11`''`'`�' TRANSFORMER 2-34 A=TYPE 2= UANTITY 34=LAMP RATING Q SPEAKER, RECESSED MOUNTED IN CEILING HORIZ HORIZONTAL STRUCTURAL ENGINEER REGISTERED IN TNE STATE OF WASHINGTON <br /> � ' Q ' � BUILDING NUMBER <br /> � HP HORSEPOWER VERIFYING COMPLIANCE WITH THESE REQUIREMENTS. <br /> � FLUORESCENT FIXTURE, 3 LAMP, TYPE AS NOTED HQ HEAT DETECTOR IN INCH PANELBOARD LOCATION <br /> INFO INFORMATION 14. AL� ELECTRICAL WORK SHALL COMP�Y WITH APP�ICABLE PORTIONS OF <br /> � CURRENT TRANSFQRMER � � GONG, SIZE AS SPECIFIED ISC AMPS SHORT CIRCUIT V56-1 C8 THE NATIONAL ELECTRIC CODE (NEC) AS WELL AS LOCAL CODES <br /> BELL, SIZE AS SPECIFIED JB JUNCTION BOX SUBSTATION � ENFORCED AT THE TIME OF CONSTRUCTION. <br /> � GROUND FLUORESCENT FIXTURE, 2 LAMP, TYPE AS NOTED � kcmil THOUSAND CIRCULAR MILLS PANEL VOLTAGE <br /> - � �wu ANNUNCIATOR KW KILOWATT <br /> QA AMMETER � FIRE ALARM PANEL KWH KILOWATI- HOUR 3 - 287/480V <br /> E KV KILOVOLT <br /> n.v VOLTMETER � TELEPHONE CABINET KVA KI�OVOLT AMPS 2 - 120/208V <br /> _ � FLUORESCENT FIXTURE ON EMERGENCY SYSTEM, TYPE AS NOTED TS TAMPER SWITCN, ADT SYSTEM PA�lE�BOARD �lAN1 NG CO�It/ENTI0�1 <br /> r� � ENCLOSED CIRCUIT <br /> Li�J BREAKER SIZE AS NOTED LS LIMIT SWITCN . <br /> CC� FLUORESCENT FIXTURE WITH BRANCH CIRCUIT <br /> XXXX END POINT AVAILABLE CONNECTION POINT 1 LAMP, TYPE AS NOTED OI SMOKE DETECTOR (TYPE AS NOTED) <br /> � FAULT CURRENT (f=10NIZATION TYPE, P=PHOTOELECTRIC TYPE) <br /> � FLUORESCENT FIXTURE WITH BRANCH CIRCUIT cR ROUGH-IN F�R SECURITY ACCESS CARD READER, 0' �° <br /> CONNECTION POINT 2 LAMP, TYPE AS NOTED 2 GANG BOX WITH SINGLE GANG PLASTER RING AND <br /> � INCANDESCENT FIXTURE, TYPE AS NOTED 3/4" CONDUIT UP TO ACCESSIBLE CEILING SPACE. <br /> � COMBINATION FLUSH FLOOR BOX WITH G R O U P <br /> � i EXIT LIGHTING SIGN, WALL MOUNTED. TELEPHONE/DATA/AV SYSTEM R�UGN-IN 600 Stewart St., Ste 1400 <br /> DIRECTION OF EGRESS AS NOTED � COMBINATION FLUSH FLOOR POKE-THRU WITH <br /> "� TELEPHONEjDATA ROUGH-IN Seattle, W�shington 9�101 <br /> � MOUNTEDTIDRECTION OFEGRESS AS NOTED PHASE 1 IFC Tel 206.267.1700 <br /> 09.34. 16 Fax 206.267.1701 <br /> SAZAN # 500-1666 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISiON SYMBOL DATE <br /> ACCEPTABILITY J. BAILEY o2.20.,3 ELECTRICAL LEGEND & A��REVIATIONS W2572915 A 09.30.16 <br /> A IRC - WBS 2.2.3,4.2 ADDITIVE MANUFACTURING W2572915 SAZAN 09.30.16 THIS DESIGN AND/OR CHECKED <br /> SPECIFICATION IS APPROVED SHEET <br /> � ENGINEER TITLE IRC - WBS 2.2.3.4.2 ADDITIVE MANUFACTURING � <br /> APPROVED BY DEPT. DATE <br /> CHECKED <br /> APPROVED 6 U I L D I N G 40_O�� JOB N0. COMP N0. . <br /> W2572915 <br /> APPROVED ELECTRICA� MASTER EVERETT, Wq °wc No. 40-056-E1 <br />