Laserfiche WebLink
JAN-25-2019 15:38 From:Arlington-Electric 360+435+6970 To:4252578857 Page:5/11 <br /> RESIDENTIAL PHOTOVOLTAIC PERMIT APPLICATION (Page 2 of 2) <br /> CITY OF EVERETT PERMIT SERVICES <br /> 3200 CEDAR STREET, EVERETT,WA 98201 <br /> (P)425-257-8810 I FAX 425-257-8857 1(E)everetteps@everettwa.gov www.everettwa.gov/perrnits <br /> • ELECPERMIT CHECKLIST PERMCHEC11(LIST . <br /> DETERMINE IF YOUR PROJECT QUALIFIES FOR AN OVER-THE-COUNTER ELECTRICAL PERMIT: <br /> If you answer yes to all of the below questions, the project qualifies for an over-the-counter electrical permit. YES NO <br /> 1.PV modules,inverters, and combiner boxes are identified for use in PV systems. .2 ❑ <br /> 2.The inverters are listed and leveled in accordance with UL 1741 and are listed for utility interaction. [IRC M2302.4) la El <br /> 3.The AC interconnection point is on the load side of service disconnect. [NEC 690.64(B)] '/G5 1<k bu-Si .A7t' ❑ <br /> 4.The system meets all current NEC, City,and Washington Cities Electrical Code requirements. .a 0 <br /> 5. For Split-Buss modules the AC interconnection must be one of the six service disconnects. J''Q <br /> 6.Maximum load added to the panel board is vased on the rating of the panelboards bus/main OCPD combination in accordance <br /> with NEC 705.12(D)(2)(3)(b), and is limited to (check the combination below that applies); <br /> 22bamp bus/200amp main OCPD-13,400AC watts, max. 70amp inverter OCPD. <br /> ❑ 225amp bus/225amp main OCPD-8,640AC watts, max.45amp inverter OCPD. <br /> [] 200amp bus/200amp main OCPD-7,860AC watts,max. 40amp inverter OCPD. <br /> ❑ 150amp bus/150amp main OCPD-5,760AC watts, max.30amp inverter OCPD. <br /> ❑ 125amp bus/125amp main OCPD-4,800AC watts, max.25amp inverter OCPD. <br /> ❑ 125amp bus/100amp main OCPD-9,600AC watts, max. 50amp inverter OCPD. <br /> ❑ 100amp bus/100amp main OCPD-3,840AC watts, max.20amp inverter OCPD. <br /> ❑ Other Electrical Permit with Plan Review Required; <br /> Note is ustea un-aiterec Tactory mainious commination.Alteration or me panelooara main Veru will require plan <br /> ravi'w <br /> Note 2:The circuit conductors and overcurrent devices shall be sized to carry not less than 125 percent of the <br /> maximum currents as calculated in 690.8(A).The rating or setting of overcurrent devices shall be permitted in <br /> accordance with 240.4(B)and (C).[NEC 690.8(B)(1)1 <br /> Note 3: If a panelboard employs a snap switch rated 30 amperes or less in any branch circuit, it cannot be rated more <br /> than 200 amperes unless there is a supply side overcurrent protection at 200 amperes or less within the panelboard. <br /> This requirement does not apply to panelboards equipped with circuit breakers.Section 408.36(a)of the NEC. <br /> 7. I have attached the following Electrical One-Line Diagram: <br /> ❑ Standard Electrical Diagram-6 Strings or Less <br /> ❑ Standard Electrical Diagram-4 Strings or Less <br /> , tandard Electrical Diagram-Micro Inverter <br /> ❑ None of the above-Electrical Permit with Plan Review Required <br /> PLEASE FILL'OUT A CITY OF EVERETT ELECTRICAL P.FRMIT A.PPLICAT/ON IF YOU QUALIFY FOR AN'OTC.ELECTRICAL'PERM1T.' <br /> AGREEMENT:I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws <br /> and ordinances governing this type of work will be completed whether specified herein or not. The granting of a permit does not presume to give <br /> authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. That I am <br /> authorized by the owner of this property to perform the work for which application Is made and I comply with the State Contractors Law 18.27 <br /> RCW and 296.200 WAC. <br /> City of Everett Oficial Use Only <br /> ASSOCIATED ELECTRICAL PERMIT'# <br /> ,-,geede• <br /> Owner/Authorized Agent Signature Date (Revised 9/30/2016) <br />