My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-41 2019-03-21
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-41
>
3003 W CASINO RD BLDG 40-41 2019-03-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2019 9:36:39 AM
Creation date
3/21/2019 9:36:37 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-41
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Er, .• <br /> 600 Q Street.Suite 200 • <br /> Sacramento.CA 95811 <br /> BUEHLER & BUEHLER <br /> tel 916.443.0303 fax 916.443.0313 <br /> structural engineers www.bbse.com <br /> July 22,2013 <br /> Tracy McCoy <br /> Liebert Precision Cooling <br /> Emerson Network Power <br /> 1050 Dearborn Dr. <br /> Columbus,OH 43085 <br /> Subject: Special Seismic Certification <br /> Liebert DS and VS Air Conditioning Units <br /> Dear Mr. McCoy <br /> This letter constitutes Special Seismic Certification for the Liebert DS and VS Air Conditioning Units <br /> limited to the sizes stated in Table 1. The units are seismically certified in accordance with the <br /> International Building Code(IBC) 2009,2012, California Building Code(CBC)2010, American Society <br /> of Civil Engineers (ASCE) Minimum Design Loads for Buildings and Other Structures, ASCE 7-05, <br /> ASCE 7-10, The method of certification is through analysis supplemented by shake table testing. <br /> Analysis <br /> The analysis has been performed using 3D finite element computer software. The section properties and <br /> capacity of each of the frame elements are calculated using CFS 6.0.4 and the 2007 NAS (ASD). The <br /> frames are modeled in SAP2000 and all members are assigned the appropriate section properties. Seismic <br /> loadings are applied statically in each orthogonal direction and the demands on each frame member is <br /> compared to the allowable capacity. The seismic load factors are iterated until the demand on each frame <br /> member is within the allowable capacity. <br /> Shake table testing data <br /> Shake table tests with similar units were used to justify the functionality of the subcomponents. The <br /> following units were shake tested: <br /> DS 070 Standard unit Sds= 1.0 z/h=1.0, [Clark Testing Lab Report#EL:10247] <br /> DS 070 Reinforced unit Sds=2.5 z/h=1.0, [Clark Testing Lab Report#EL:10247] <br /> DA125 Reinforced unit Sds= 1.65 z/h=1.0 [Clark testing Lab Report#EL:9954,OSHPD OSP-270-10) <br /> Functionality tests were performed for the above noted units and each passed satisfactorily.Any observed <br /> structural damage during these tests was considered. The active and energized subcomponents used in <br /> these tests are representative of those considered in the analysis and listed in Table 1. The combination of <br /> analysis and the shake table testing data has been used to certify the units noted. <br /> Certified Unit List Seismic Parameters <br /> The below referenced equipment is certified for seismic applications when properly installed, used as <br /> intended, and located in United States where the"design 5 percent damped spectral response acceleration <br /> at short periods adjusted for site class effects", Sds, is as shown in the Table 1. Below grade, at grade or <br /> above grade installations are permitted and included in this approval. <br /> rU <br /> Page 1 of/ / <br /> BUEHLER & BUEHLER structurat engineers <br />
The URL can be used to link to this page
Your browser does not support the video tag.