Laserfiche WebLink
ir,- SNOHOMISH <br /> HEALTH DISTRICT <br /> WWW;SNOHD.ORG Environmental Health Division <br /> December 10, 2015t_\ ©E_vED <br /> Maria Lourdes Nunez <br /> 210 98th PI SE#C DEC 1 4 2015 <br /> Everett, WA 98208 <br /> J Proposed, tWIy &"J, TY <br /> Subject: A &A Café &Tamaleria LLC, 607 SE Everett a 1 f i t <br /> Dear Ms. Nunez: <br /> Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with <br /> the policies of the Snohomish Health District. With the addition of the following conditions, the plans <br /> are approved. <br /> 1. The conditional approval of the plans for A&A Café &Tamaleria LLC was based upon the <br /> plans, menu, and HACCP submitted November 29, 2015. Any changes to these items without <br /> preapproval from the Health District will void this approval. <br /> 2. The Health District operating permit application process.must be completed prior to opening for <br /> business. This facility will be classified as a high risk food establishment with 13-50 seats. <br /> 3. An indirect waste.drain (an air gap) is required for the food preparation sink, three-compartment <br /> sink, ice machine, walk-in refrigeration, and;any equipment in which food or food contact equipment <br /> is placed.. <br /> 4. A horizontalseparation of at least 16 inches or a vertical partition 16 inches in height is required <br /> between the handwash sink and all food preparation areas. <br /> 5. A.horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required <br /> between the 3-compartment sink (item #5) and the food prep sink(item #8). , <br /> 6. Only one food preparation sink is indicated on the floor plan. Because of this, only vegetable <br /> preparation will be allowed at this sink. No rinsing or thawing under running water of raw meat, <br /> poultry, and/or seafood will be allowed without the installation of an additional and separate food <br /> preparation sink. If installed, the location of any additional food preparation sink must be approved <br /> prior to installation. The sink must be NSF listed or equivalent, be indirectly drained, and have at <br /> least one integral drainboard. <br /> 7. If splashguards (equipment, partitions and/or walls) are provided on both sides of a handwash sink, <br /> the distance between the splashguards must be at least 18 inches apart (shoulder width) to allow <br /> proper access to the handwash sink. <br /> 8. Water heaters must be of sufficient size to completely fill two compartments of the 3-compartment <br /> sink with hot water and still be capable of providing at least 100°F water at the handwash sinks. <br /> 9. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 10. All food service equipment, both new and used, must be listed by the National Sanitation <br /> Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br /> holding food at temperature of 41°F or below. <br /> 11. Extra wall protection is<required on walls behind all sinks, including restroom handwash sinks, and <br /> food..preparation countersand tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> , reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall ` <br /> behind counter top equipment taller than.16 inches. Floor to ceiling protection is required on the <br /> wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. <br /> Plastic coated hardboard is not acceptable. <br /> 3020 Rucker Avenue, Suite 104 ■ Everett, WA 98201-3900■�`I I: 425.339.5250 ■ fax: 425.339.5254 <br /> �j� <br />