My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2804 GRAND AVE BROOKLYN BROS PIZZERIA 2019-03-22
>
Address Records
>
GRAND AVE
>
2804
>
BROOKLYN BROS PIZZERIA
>
2804 GRAND AVE BROOKLYN BROS PIZZERIA 2019-03-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2019 8:23:53 AM
Creation date
3/22/2019 8:23:51 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2804
Tenant Name
BROOKLYN BROS PIZZERIA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Call (425)257-8124 for more information. <br /> 2. Fire Alarm System - An approved automatic fire detection system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to Permit Services for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department Inspector, shall be performed, along <br /> with a certificate of completion,prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72, 2013 Edition. <br /> Installation of fire alarm components, including basic wiring, may not commence before <br /> plans are approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br /> professionally rendered, in sufficient detail, and must be internally consistent. Riser <br /> diagrams must match installation plans and load calculations. Components must be listed <br /> and approved for use together. Changes to plans must include new drawings and calculations <br /> and must be approved by the Fire Department Plan Reviewer prior to installation. Fire alarm <br /> installation is subject to field inspection by a Fire Department Inspector. An approved set of <br /> plans and the City of Everett Permit Services electrical permit must be present for any <br /> installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Permit Services. <br /> Electrical inspections and approval are required prior to calling for acceptance tests. Call <br /> (425)257-8810 opt 8 for permit information.The absence of monitoring for the alarm.system <br /> will be cause for postponing Fire Department inspection and testing and shall result in denial <br /> of occupancy. A copy of NFPA 72 Record of Completion form must be filled out prior to <br /> final occupancy (NFPA 72, 2013 Edition, Chapter 7, pages 107-147). 2015 IFC, 907.7.2. <br /> Call for design requirements per Authority Having Jurisdiction. Automatic smoke detection <br /> is required. Note: Building has existing sprinkler and alarm system. Those two systems need <br /> to be integrated into new area for Brooklyn Bros Pizza. <br /> F <br /> Snohomish Health District—Elaine Hagedorn—425.339.8742 <br /> 1.An approval letter from the Snohomish Health District dated December 11, 2017 was issued <br /> and outlines conditions of approval and requires a preoperational inspection. <br /> rt <br /> i <br /> RE 18-002 <br /> Page5o <br />
The URL can be used to link to this page
Your browser does not support the video tag.