GEN ERAL NOTES
<br /> THIS ELECTRICAL PLAN IS THE ARCHiTECT'S SUGGESTED LAYOUT. THE _ .
<br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL
<br /> CONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER AND SHALL
<br /> � CONFORM T0 THE APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS
<br /> SNOWN ON THIS DRAWING_
<br /> �;
<br /> ,
<br /> METER CENTER LOCATIONS SHALL BE COORDtNATED WITH THE ARCHITECT. �-�------------------�-�
<br /> � � ,
<br /> �
<br /> ,
<br /> NIGHEST OPERABLE PART QF ENVlRONMENTAL AND OTHER GONTROLS SHALL � � � [ � � �, � V� � �", -
<br /> MOUNTED NOT LESS THAN 36 WCNES ABOVE FLOOR. �LECTRIGAL AND P1tIO j I
<br /> COMMUNICATIONS SYSTEMS ON WALLS SNALL BE MOUNTED A MW. OF 15 I I ' ` °
<br /> fNCHES ABOVE FLOOR. � � �
<br /> � � � I � � ;� � 5; :`
<br /> i i i � � � '
<br /> OUTLETS, SWITCHES, TELEPHONE AND TV, ETC. BOXES fN PARTY WALLS OF � � � � �� ��,���.�� ���R s��#�� ���I, :
<br /> ONE UNiT SHALL BE IN DfFFERENT STUD SPACES THAN THOSE IN � '
<br /> THE ADJACENT UNIT. NQ TWQ ADJACENT UNITS SHALL HAVE SUCH BOXES � 3 I �����������������°�`< �����'
<br /> IN TNE SAME STUD SPACE. BOXES SHALL BE SEPARATEQ HORIZONTALLY �. � .._. � ,� �������`����� :� ������ ���8' •
<br /> 3 r
<br /> � � ���#�,r$+it,��1! [�F��C{It�[��'q�'C�I tUF1Tt: :`'
<br /> BY 24 .
<br /> ' � � , ;.s� .,.
<br /> I �� 1000W ELEC �/ ( ' 1500W ELEC
<br /> INDIVIDUAL ELECTR)CAL OUTLET BOXES SHALL BE OF STEEL OR OTH�R � I CEIL(NG NEATER � � ,, CE(LING HEATER 70P HALF , ' j �
<br /> APPROVED MATERIAL AND SHALL NOT BE GREA7ER 7HAN 16 SQUARE � � � �U '� TO j
<br /> INCHES IN AREA. , � j , �� -. FIREPLACE �.- - -..� f � ,
<br /> �j � �. \ / � �. 5052 REGISTERED
<br /> THE WATER HEATERS SHALL BE STRAPPED PER 1RC P2801.7 AT A POINT � / � I 1 '� � � I � � ARCHITECT
<br /> , i CFP i � � �I�1�' i � ' i �
<br /> WITHIN THE UPPER 1/3 AND TNE LOWER 1/3 OF !TS VERTICAL DIMENSION. � j
<br /> THE LOWER STRAP SHALL BE NOT LESS THAN 4" ABOVE ANY CONTROLS. , � Master � � I `� � I , \ I �
<br /> � SMURF�' I � / � �. �
<br /> WATER NEATERS SHALL BE PROVIDED WiTH A PRESSURE/T�MPERATURE � � i , ��y�� � ROBERT E. WEIBLE
<br /> RELI�,F VALVE THAT IS CONNECTED TO A DRAIN LINE. THE DRAIN LINE � Bedroom 1 TUBE � g � I STATE OF WASHiNGTON
<br /> SHALL BE DIRECTED TOWARD THE GROUND AND TERMINATE AT A POINT NO � j � � ` � T� � � , � ,
<br /> / �
<br /> LESS TNAN 6" AND NO MORE THAN 24" ABOVE THE GROUND, , I � i, � � � �J It � ' / � '
<br /> f I ,
<br /> SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP, SHALL � � � I I � ` �
<br /> EMIT A SIGNAL WHEN BATTERIES ARE LOW, SHALL BE PERMANENTLY HARD ' � � TEL � ' � � 1 � � ' �
<br /> WIRED ANQ WITHOUT A DISGONNECTING SWITCH OTHER TNAN THQSE r- � � � � _._ _ _ � � �. �. ! �_T_ �
<br /> T 1 � �_—_ I �_—_ � �
<br /> REQUIRED FOR OVERCURRENT PRQTECTION, AND SHALL SOUND AN ALARM � � ` � � � STACK �.�. I � �
<br /> AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE i s� 25ow wa��3 3 � i THERMOSTAT �.� � j � �
<br /> 1 _. � UNIT HEATER { � --r-,--- T I 1 �
<br /> LOCATED. � M. � ' �. � i & SW{TCH ----- � � ! I
<br /> E E R T E � Bath.�- _ - ` � ' � � ' -__ - �_____ �_ ;__ _____ _- ' � a
<br /> N GY N� S '
<br /> ,
<br /> / � -� ' / � , � :..�� � - - - - i, _ 3 � � �
<br /> SEE ENERGY NOTES ON SHEET A1 & d5. � i �. � ��1 � �- � ` � I �
<br /> 1 / VTR �.�., � � � _
<br /> \ l � I �I� � i � C ( i z
<br /> WATER NEATER SNALL BE FUELED 8Y GAS AND HAVE A MlNIMUM EF OF , � , ���:�: � � � � � � � j �
<br /> 0.82 � � � � I
<br /> ' � ; ; � i � � z � �
<br /> � � ii
<br /> � � w
<br /> HOT AND COLD WATER HEATER� PIPES IN UNCONDITIONED SPACES SHALL BE � o � � � � � � F �. � �; � � � �.�.. � � z � �
<br /> I N S U L A T E D W f T H R-3 I N S U L A T I O N W H�(C H H A S A F L A M E S P R E A D O F 2 5 O R � � i � � � ' 1 . � � � � � � � �� � > 4 "
<br /> LESS. ' � I 1 �� I I V C[�I�1� .� � � � v �
<br /> � g i DR�R � � .. 7 �, i i j \ i.�.... 1 , � � �
<br /> I� i � � � ` e
<br /> VENTILATICJN NOTES ' ; , ' } ; ; ___�, ' ; `��' C i \ E EC i ' � � �
<br /> o WH 1 I i i \ �.:
<br /> PA E
<br /> C , � � � E ��; ; Kit hen �; ; j ��� � , � o o �
<br /> � � VTfR � , , ,..... r.,
<br /> VENTILATION: SEE NOTES ON COVER SHEET. "� � �� I+4 ' � f.; t; ; � �j ;:�::;; I o
<br /> � � a� �
<br /> ' �� �� 1 WASNER � DW �i 1 ���� �z5ow ;..... _,, � � � �
<br /> ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL B� FITTED WITH A � � `� � ' � + --�'�i � i ELEC i $�: i i ` � I � � o .�'
<br /> ' BathvT , � ; � i i � � CEILING ; , , o � � �.
<br /> i a i �
<br /> TIGHT FITTING BACKDRAFT DAMPER CAPABLE OF CLOSING WHEN THE FAN IS f�T-
<br /> , , a , � HEATER � � r-
<br /> GFCI��I �. I k� � ./ . MI � � 2
<br /> �\ I I / �"...�. 1 0
<br /> V �
<br /> � , / � _as. � � - � .. NG
<br /> NOT IN USE. , --------------�= �1=------- � � � O
<br /> �:------- CElL! � � ' a �
<br /> DUCTS IN UNHEATED SPACES INCLUDING AT T(CS SHALL BE INSULATED TO A ' ____ \� ` ; _____^_:_;________^______ ._____.__�. � � � �� � \ "' �
<br /> MINIMUM OF R-8. ---------- ' r----�.--- �� � � m � � � .
<br /> , W � �' ' � \ `'�. � i � �.\ �._ � �.
<br /> TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ATT(C. E�Ec � � � ••
<br /> � ,
<br /> , PANEL � ' 6�,6>, \ � , � \ j I � �
<br /> DRYER EXHAUST DUCT SHALL BE 4" RIGfD METAL WITH A 4" OPENING ON � � � � � jI 3 I / �� E rY � , ' u�
<br /> T H E E X H A U S T H O O D. T H E D R Y E R S D U C T S S H A L L B E G A L V A N I Z E D S T E E L O R � � S� // TECH ' � � � � �� G ara ge , �' I a o
<br /> ALUMINUM, MINIMUM 0.016 THICK. THE DRYERS SHALL BE GENERAL ' � T e c h P O R T , � � � � r'
<br /> ELECTRlC. DRYERS SHALL BE )NSTALLED ACCORDING TO MANUFACTURER'S ; Be droom 1 � , � , i � � . ' � AT CElLING: PREWIRE 450W
<br /> ( LOW VOLTAGE WIRE FOR
<br /> INSTALLATION INSTRUCTIONS ON SITE. �� T� ; Area � � , � � ELEC � � ,
<br /> � � � GARAGE DOOR OPENER BASEBOAR
<br /> WINDOW OUTDOOR AIR INLETS SHALL PROViDE THE EQUIVALENT OF 4 SQ. � � ' DICIIC� PENDAN7 � � i AND ELECTRIG EYES � � - (n
<br /> IN. OF NET FREE AREA. \ TOP ; . , I I VERIFY LOCATION WITH � 3 � '
<br /> i I �' ���VV. .C';:.. `
<br /> ' HALF � TEGH � .J.... ........... � Z �
<br /> � 500W EI.EC PaR�r _ ' i �PENER INSTALLATlON o ( Q ,
<br /> � o
<br /> � CEILING HEATER � � �j I ....::.::.:...... ! � BEII a N
<br /> � � � { _ � � - --- LL a � � .
<br /> 750W EIEC 1500W EIEC I 1 � % O
<br /> CEILWG HEATER CEILING HEATER � � � HOSEI / � J
<br /> � BieB� , t(
<br /> . L--___-_---�_-______J . . / - ..
<br /> - U
<br /> \ � �� ------------------\-=_��-�_----------� � �
<br /> ELECTRICAL LEGEND �., PyoQ�E�� = v 3Q
<br /> ` W 6 �
<br /> � DUPLEX RECEP7ACLE OUTLET DIRECTIONAL CEfLING ..� � �
<br /> MOUNTED LIGHT W
<br /> � DUPLEX RECEPTACLE OUTLET
<br /> SPLIT WIRED (SWITCH TOP NALF) UPPER LEVEL MAIN LEVEL
<br /> � CEILING MOUNTED LIGHT _ .
<br /> M� DUPLEX RECEPTACLE OUTLET �� �
<br /> MICROWAVE RECESSED CEILING LIGHT• U N IT F uTINTY PLAN UTILITY PLAN LOWER LEVEL
<br /> � � N IT F UTILITY PLAN °� �
<br /> � IC RATED - SEE 12/Q1 1/4"=1'-0" 1/4"=1'-0" a �i
<br /> � S�NGLE REGEPTACLE OUTLET 1/4"=l'-0" `�' d.
<br /> 208v (R: RANGE, D: DRYER) -�} WALL MOUNTED LIGHT r
<br /> Q JUNCTION BOX
<br /> DOUBLE TUBE FLUORESCENT
<br /> � TECH PORT CEILING MOUNTED LIGHT �
<br /> �
<br /> TEL.� TELEPHONE JACK � CEILING MOUNTED TRACK LIGNT �
<br /> 4 TV TELEVISION JACK �
<br /> � HEAT LAMP, EXHAUST FAN Q `� ,
<br /> � SINGLE POLE SWITCH COMBINATION RECESSED CEILfNG
<br /> �
<br /> FIXTURE - 250W LAMP, 50 CFM O �
<br /> �3 THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT. �
<br /> SEE 15/D1 �
<br /> DIM.� DIMMER SWITCH �u�������� BEARING WALL - SEE NOTES > �
<br /> THIS SHEET REGARDING BOXESW � +Q+ U
<br /> �T TIMER SWITCH AND FlRE-RATED WALLS
<br /> �l �
<br /> � RECESSED CEILING EXHAUST FAN � METER CENTER � � � V�
<br /> 50 CFM MIN, 3 SONES MAX, � � y Q�
<br /> 4" ROUND DUCT. SEE 15/D1 � ELECTRICAL PANEL � � �
<br /> MIGROWAVE QVEN/RANGE HOOD B� ELECTRiC BASEBOARD
<br /> ��� HEATER � � � �
<br /> �W COMBlNATtON, 100 CFM, 3 SONES � L-
<br /> � � � �
<br /> SMOOTH DUCT. �T THERMOSTAT O � Z
<br /> � RECESSED HEAT L.AMP - � SMOKE DETECTOR
<br /> �t" NUTQNE 9410N, 250W LAMP WITH BATTERY BACKUP
<br /> � W �
<br /> CEILING FIXTURE. SEE 12/D1 .�.� O
<br /> � CARBON MONOXIDE .� �
<br /> � PHOTOCELL SAFETY SENSOR ALARM/SMOKE DETECTOR � �
<br /> _ —
<br /> ❑ TECH PANEL � AUDIBLE SPRINKLER
<br /> SFA FLOW ALARM O �
<br /> � RECESSED CElLIf�G WHQLE WINDOW WITH OUTDOOR �
<br /> �F HOUSE EXHAUST FAN �� A!R INLET
<br /> 80 CFM MIN., 120 CFM MAX., �
<br /> 1.5 SONES, 6" ROUND DUCT �PB PUSH BUTTQN
<br /> VTR VENT THROUGH ROOF � 1ob No.: 13-47
<br /> �
<br /> �,�
<br /> � Sheet No.:
<br /> z
<br /> � U12