Laserfiche WebLink
Refer to the local and state standards for a complete description of the inspection, testing, and maintenance requirements.The <br /> inspection results provided in this report are based only on the system's current ability to operate and shall not be construed as an <br /> evaluation of the system's performance capabilities to adequately protect the property. Information in this report may or may not <br /> include possible performance concerns and should not be considered all inclusive.It is solely the property owner's responsibility to <br /> determine if a separate investigation should be done to ensure the system will perform as designed and that the property is adequately <br /> protected.It is also the property owner's responsibility to maintain the system,property and any possible environmental conditions that <br /> may affect the system's operability and performance. <br /> :SYSTEM FUNCTIONALITY:: <br /> SYSTEM <br /> Hydraulic nameplate installed and visible on riser? O Yes 4 No <br /> Main Drain flow test conducted? <br /> ® Yes 0 No <br /> Main Drain test pipe size? 2 inches <br /> Static Pressure: <br /> 65 psi <br /> Residual Pressure: 55 psi <br /> Flow switches,supervisory switches,and alarm bell tested? ® Yes 0 No 0 N/A <br /> Electric Bell-operates properly? ® Yes 0 No 0 N/A <br /> Water Motor Gong-operates properly? 4 Yes 0 No 0 N/A <br /> Central Station monitoring company received signal? ® Yes 0 No 0 N/A <br /> Pipe and valves internally inspected for obstruction?(5 year) ® Yes 0 No 0 N/A <br /> System gauges replaced or calibrated?(5 year) 4 Yes 0 No 0 N/A <br /> Was antifreeze solution checked and does system operate properly? ® Yes 0 No 0 N/A <br /> VALVES <br /> Pressure regulating valves tested? 0 Yes 0 No 4 N/A <br /> Valves are sealed,locked,or supervised properly? 4 Yes 0 No 0 N/A <br /> Control valves have proper signage? 4 Yes 0 No 0 N/A <br /> Valves inspected and lubricated? 4 Yes 0 No 0 N/A <br /> SPRINKLERS <br /> Number of known sprinklers: na <br /> Proper number of spare sprinklers available? ® Yes 0 No 0 N/A <br /> Sprinkler wrench available for each type of sprinkler? * Yes 0 No 0 N/A <br /> Sprinklers free of corrosion,paint,and/or physical damage? ® Yes 0 No 0 N/A <br /> Minimum clearance above top of storage to sprinkler deflector?(18"typically) * Yes 0 No 0 N/A <br /> Sprinklers(standard response)are less than 50 years old? ® Yes 0 No 0 N/A <br /> Sprinklers(fast response)are less than 20 years old? 4 Yes 0 No 0 N/A <br /> Sprinklers(dry type)are less than 10 years old? ® Yes 0 No 0 N/A <br /> Sprinklers(extra high temperature)are less than 5 years old? I Yes 0 No 0 N/A <br /> Sprinkler sample has been successfully tested within last 10 years? ® Yes 0 No 0 N/A <br /> FIRE DEPARTMENT CONNECTION 0 Yes * No <br /> INSPECTION COMPLETION <br /> Full walk through performed? Yes 0 No 0 N/A <br /> Owner has been advised to protect water filled sprinkler piping from freezing? II Yes 0 No 0 N/A <br /> System left in service? <br /> * Yes 0 No <br /> Inspection tag posted at main valve? <br />