Refer to the local and state standards for a complete description of the inspection, testing, and maintenance requirements. The <br /> inspection results provided in this report are based only on the system's current ability to operate and shall not be construed as an <br /> evaluation of the system's performance capabilities to adequately protect the property. Information in this report may or may not <br /> include possible performance concerns and should not be considered all inclusive.It is solely the property owner's responsibility to <br /> determine if a separate investigation should be done to ensure the system will perform as designed and that the property is adequately <br /> protected.It is also the property owner's responsibility to maintain the system,property and any possible environmental conditions that <br /> may affect the system's operability and performance. <br /> SYSTEM` 3N; r.NALITY'; <br /> SYSTEM <br /> Hydraulic nameplate installed and visible on riser? $ Yes 0 No <br /> HYDRAULIC NAMEPLATE INFORMATION <br /> Recorded design density?(gpm per sq.ft.) <br /> na gpm per sq.ft. <br /> Indicate pipe schedule: 0 Light 0 Ordinary 0 Extra S N/A <br /> Main Drain flow test conducted? 0 Yes S No <br /> Main Drain test pipe size? 2 inches <br /> Static Pressure: <br /> 65 psi <br /> Residual Pressure: 55 psi <br /> Trip Test Conducted? <br /> 0 Partial * Full 0 N/A <br /> Date of last full Trip Test? 03-24-2017 (MM-DD-YYYY) <br /> System tripped in: 26 sec <br /> Flow switches,supervisory alarms,and air maintenance devices tested? ® Yes 0 No 0 N/A <br /> Electric Bell-operates properly? <br /> IIS Yes 0 No 0 N/A <br /> Water Motor Gong-operates properly? <br /> ® Yes 0 No 0 N/A <br /> Central Station monitoring company received signal? it Yes 0 No 0 N/A <br /> Pipe and valves internally inspected for obstruction?(5 year) • Yes 0 No 0 N/A <br /> System gauges replaced or calibrated?(5 year) * Yes 0 No 0 N/A <br /> VALVES <br /> Pressure regulating valves tested? 0 Yes 0 No * N/A <br /> Valves are sealed,locked,or supervised properly? ® Yes 0 No 0 N/A <br /> Control valves have proper signage? ® Yes 0 No 0 N/A <br /> Interior of system valve inspected and cleaned thoroughly? ® Yes 0 No 0 N/A <br /> Valves inspected and lubricated? Yes 0 No 0 N/A <br /> SPRINKLERS <br /> Number of known sprinklers: na <br /> Spare sprinklers available? * Yes 0 No 0 N/A <br /> Sprinkler wrench available for each type of sprinkler? S Yes 0 No 0 N/A <br /> Sprinklers free of corrosion,paint,and/or physical damage? * Yes 0 No 0 N/A <br /> Minimum clearance above top of storage to sprinkler deflector?(18"typically) 416Yes 0 No 0 N/A <br /> Sprinklers(standard response)are less than 50 years old? ® Yes 0 No 0 N/A <br /> Sprinklers(fast response)are less than 20 years old? Yes 0 No 0 N/A (l <br /> Sprinklers(dry type)are less than 10 years old? * Yes 0 No 0 N/A <br /> Sprinklers(extra high temperature)are less than 5 years old? * Yes 0 No 0 N/A <br />