<br /> .8„ ...4-'Ht5�1'a�N.)(.��aN'=.(4N4 11,,.+./�;i� }� 4,�d , ¢>sa. 4 WINDOW& DOOR SCHEDULE
<br /> GENERAL NOTES CLIMATE ZONE 5 AND MARINE-4 NOTE: ALL WINDOWS ARE EXISTING VINYL WINDOWS
<br /> CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR
<br /> • TO COMMENCING THE WORK. -
<br /> FENESTRATION U-FACTOR IkI
<br /> WORK SHALL COMPLY WITH THE FOLLOWING CODES: 0.30
<br /> -
<br /> 2015 INTERNATIONAL RESIDENTIAL CODE SKYLIGHT U-FACTOR Ik! 0.50 Vertical Fenestration(Windows and doors) ACTUAL SIZEtq
<br /> 2015 WASHINGTON ENERGY CODE z
<br /> GLAZED FENESTRATION SHGC Ike! NR p
<br /> OTHER CODES APPLICABLE BY JURISDICTION. - - Component - Width Height Sill
<br /> CEILING R-VALUE IM 49 Inch Inch Inch
<br /> Description Ref. U-factor Qt. Feet Feet Feet Area UA
<br /> AIR SEALING WOOD FRAME WALL R-VALUE(GI 21 INT
<br /> 1, ALL PLUMBING,ELECTRICAL,AND HVAC PENETRATIONS IN FLOOR, MASS WALL R-VALUE Id! • 21121. D1-SOLID DOOR-FRONT DOOR WSEC 0.60 1 3 ° 6 8 0 ° 20.0 12.00 p a
<br /> WALLS,AND CEILINGS ARE CAULKED AND SEALED, FLOOR R-VALUE 30 D2-SOLID DOOR W/LITE-BACK DOOR WSEC 0.60 1 2 8 6 8 0 0 17.8 10.67 w
<br /> S
<br /> 2. WHERE PENETRATIONS NEED A FIRESTOP,DISCUSS WITH BUILDING o N
<br /> OFFICIAL. BELOW-GRADE WALL R-VALUE le,cl 10/15/21 INT•TB 0.0 0.00
<br /> 3. ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR WALLS SLAB R-VALUE 8 DEPTH Ig,hl 10,2FT
<br /> MUST BE SEALED AT THE BACK OF THE RECEPTACLE OR SEALED WITH W1-PIC WSEC 0.30 1 2 0 2 0 4 11 4.0 1.20 2 o
<br /> FACEPLATE GASKETS. ENERGY REQUIREMENTS FOR ALTERATION AND ADDITIONS,PRESCRIPTIVE W2-SH WSEC 0.30 1 3 1 4 10 2 3 14.9 4.47
<br /> 4 SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT LIKE �� -i
<br /> "TYVEK"ON EXTERIOR. APPROACH -WSEC TABLE R402.1.1 W3-XO WSEC 0.30 1 3 ^ 1 11 5 2 6.4 1.92 Z
<br /> 5. VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS,4 MIL. a. R-VALUES ARE MINIMUMS.U-FACTORS AND SHGC ARE MAXIMUMS. n z
<br /> VISQUEEN OR AN APPROVED VAPOR BARRIER PAINT. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN W4-SH WSEC 0.30 1 3 1 4 10 2 3 14.9 4.47 d
<br /> THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE Cln ^m
<br /> SEPARATION BETWEEN DWELLING AND GARAGE/CARPORT COMPRESSED 8-VALUE OF THE INSULATION FROM APPENDIX TABLE W5-SH WSEC 0.30 1 3 7 2 ° 5 2 7.2 2.15 �� _
<br /> a. NO SEPARATION REQUIRED IF ENTIRELY OPEN ON 2 OR MORE SIDES A701.4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE f n
<br /> AND NO TABLE. THE VALUES IN ITEMS B.THROUGH H.BELOW APPLY TO W6-XO WSEC 0.30 1 2 10 2 10 3 6 8.0 2.41 r/
<br /> ENCLOSED USES.(OPEN DECKS ABOVE ARE OKAY. NON-RATED ALTERATIONS AND ADDITIONS,AND ARE FOR WOOD FRAMING ONLY-
<br /> U�
<br /> WALLS AND OPENABLE WINDOWS BETWEEN THE DWELLING AND W7-SH WSEC 0.30 1 3 11 2 11 3 10 11.4 3.43 IW W
<br /> CARPORT ARE OKAPI. METAL FRAMING NOT ALLOWED UNDER PRESCRIPTIVE APPROACH.FOR _ c
<br /> b. MINIMUM 1/2"GWB ON GARAGE/CARPORT SIDE OF WALLS REQUIRED FOR ALTERATIONS ONLY,WHERE EXISTING FRAMING REMAINS AND THE W$-SH/PIC WSEC 0.30 1 7 10 2 9 4 4 21.5 6.46
<br /> FRAMING CAVITY IS EXPOSED DURING CONSTRUCTION,THE CAVITY MUST
<br /> ALL GARAGES/CARPORTS NOT COVERED BY 1A ABOVE. r
<br /> C. 1-HOUR FIRE RATED WALL REQUIRED IF LESS THAN 5 FEET FROM BE FILLED WITH INSULATION.WHERE THE FRAMING INSULATION IS NOT W9-SH/PIC WSEC 0.30 1 7 10 3 8 3 5 28.7 8.62
<br /> PROPERTY LINE (NO OPENINGS ALLOWED LESS THAN 3' FROM PROPERTY EXPOSED DURING CONSTRUCTION,NO ADDITIONAL IS 3 10 2 kiiill
<br /> LINE,25MAXIMUM OPENINGS BEALLOWED 3'AND 5'TO PROPERTYMPROPERTY
<br /> REQUIRED.WHERE NEW FRAMING IS INSTALLED,FULL INSULATION IS W10-PIC WSEC 0.30 1 4 4 2 20.5 6.16
<br /> REQUIRED AS SPECIFIED BELOW:
<br /> OVERHANGS MUST BE A MINIMUM 2'FROM PROPERTY LINE, EXCEPT. W11-PIC WSEC 0.30 1 4 3 4 10 2 2 20.5 6.16 APPROVALs7AMP
<br /> b. MIN.CEILING INSULATION=R-49(R-38 IF FULL THICKNESS OF
<br /> STEEL GUTTER ALLOWED CLOSER AND 5/8"GWB SHEATHING REQUIRED INSULATION EXTENDS OVER THE WALL TOP PLATE) FOR SINGLE RAFTER W12-SH WSEC 0.30 1 2 7 4 10 2 2 12.5 3.75
<br /> ON UNDERSIDE WHEN 5'OR LESS FROM PROPERTY LINE. OR JOIST-VAULTED CEILINGS,THE INSULAITON MAY BE REDUCED TO
<br /> EGRESS WINDOWS:REQUIRED FOR 1 WINDOW/BEDROOM OR SLEEPING AREA N-DR.
<br /> c. INT.(INTERMEDIATE FRAMING)DENOTES STANDARD FRAMING 16 INCHES •
<br /> (BELOW 4TH FLOOR)AND 1 WINDOW/BASEMENT. Sum of Vertical FenestrationArea and UA 208.4 73.86
<br /> ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF R-10
<br /> a. MIN.NET CLEAR AREA = 5.7 SQ.FT.,(MIN. 3'0"x 4'6"IF DOUBLE HUNG INSULATION.LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE Vertical Fenestration Area Weighted U=UA/Area 0.35
<br /> OR 4'0"x 3'6"WINDOW IF SLIDER). 5.0 SQ. FT. IF SILL HEIGHT IS THICKNESS OF 3.5 INCHES ARE EXEMPT FROM THE INSULATION
<br /> WITHIN 44"OF GRADE(ABOVE OR BELOW). REQUIREMENT.
<br /> b. MIN. NET CLEAR OPENING WIDTH=20";MIN.NET CLEAR OPENING d. MIN ABOVE-GRADE"MASS WALL"INSULATION(TYPICALLY CONCRETE OR WINDOW& DOOR SCHEDULE NOTES:
<br /> HEIGHT=24" CMU(=R-21 CAVITY OR R-21 CONTINUOUS.THE SECOND R-VALUE 1. XO= SLIDER,SH =SINGLE HUNG,DH = DOUBLE HUNG, FIX = PICTURE,C = CASEMENT
<br /> c. MAX.SILL HEIGHT= 44"ONE PERMANENTLY INSTALLED STEP WITH APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIRO 2. IF CONTRACTOR DECIDES TO REPLACE WINDOWS,THEY UST MEET ENERGY
<br /> MAX.8"RISE AND MIN.9"RUN OKAY FOR EXISTING BEDROOMS). OF THE MASS WALL. PERFORMANCE STANDARDS, HEAT TREATMENT REQUIREMENTS AND EGRESS
<br /> REQUIREMENTS. GNeer,srAt.+v
<br /> e. "10/15/21 • TB"MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR 3. ALL WINDOWS SHALL BE NFRC CERTIFIED.
<br /> REQUIRED GLAZING FOR HABITABLE ROOMS: OF THE WALL,OR R-15 CONTINUOUS INSULATION ON THE INTERIOR OF 4. CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT REQUIREMENTS WITH WINDOW
<br /> a. MIN.GLAZED EXTERIOR OPENING AREA= 8%OF FLOOR AREA. THE WALL,OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK
<br /> b. GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY INSTALLED BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF &DOOR MANUFACTURER.
<br /> ARTIFICIAL LIGHT iS PROVIDED. THE BASEMENT WALL."10/15/21 +TB"SHALL BE PERMITTED TO BE MET 5. CONTRACTOR TO VERIFY WINDOW AND DOOR DIMENSIONS PRIOR TO ORDERING WINDOWS.
<br /> c. OK IF OPENINGS ARE BELOW DECK & ROOFED PORCHES w/MIN.CEILING WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT 6. EGRESS WINDOWS SIZED FOR "MILGARD STYLE LINE"SERIES WINDOWS.CONTRACTOR TO
<br /> HEIGHT OF 7 FT.(LONG SIDE 651 OPEN). WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR VERIFY EGRESS REQUIREMENTS IF A DIFFERENT MANUFACTURER/MODEL IS CHOSEN.
<br /> EXTERIOR OF THE WALL."TB"MEANS THERMAL BREAK BETWEEN FLOOR
<br /> MECHANICAL/VENTILATION: REQUIRED FOR HABITABLE ROOMS OF ADDITIONS SLAB AND BASEMENT WALL.
<br /> AND ALTERATIONS MORE THAN 500 SQ.FT.OR THAT INCLUDE A KITCHEN, f. MIN. FLOOR INSULATION ABOVE UNHEATED SPACE = R-30
<br /> BATHROOM AND OTHER AREAS WHERE COOKING ODOR OR EXCESS WATER g. MIN. PERIMETER INSULATION FOR UNHEATED SLAB ON GRADE = 8-10
<br /> VAPOR WILL BE PRODUCED. UNDER ENTIRE SLAB PLUS R-10 FOR 2 FEET
<br /> a. MIN. 50 CFM FOR BATHROOM AND LAUNDRY;MIN.100 CFM FOR h. MIN. INSULATION FOR HEATED SLAB ON GRADE = R-10 UNDER ENTIRE OTHER REQUIREMENTS:
<br /> KITCHEN. SLAB PLUS R-10 PERIMETER INSULATION.SEE R402.2.9.1 OF THE WSEC. a. GUARDRAILS: MIN.36"FIT. MAX.4"SPACING BETWEEN
<br /> b. MIN.AIR INTAKE OPENINGS=4 SQ.IN.PER ROOM. i. MAX.WINDOW AND DOOR(FENESTRATION!U-FACTOR = U-30.THERE ARE INTERMEDIATE MEMBERS(42"MIN. HT.FOR R-2 EXTERIOR!.
<br /> c. WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN IRC M1507.3 NO SHGC REQUIREMENTS IN THE MARINE ZONE. b. FLOORINGS:BOTTOM MIN.12"BELOW GRADE,TOP OF FOUNDATION
<br /> j. IN ANY ONE DWELLING UNIT(INCLUDING BOTH NEW AND EXISTING WALL MIN.6"ABOVE GRADE.
<br /> SMOKE ALARMS: REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS AND ON PORTIONS!,ONE SIDE-HINGED DOOR UP TO 21 SQ FT PLUS UP TO 15 SQ c. CONCRETE SLABS ON GRADE:3-1/2" MIN.THICKNESS.
<br /> ALL FLOORS. DIRECT WIRING IS REQUIRED FOR SMOKE DETECTORS,UNLESS FT OF GLAZED FENESTRATION CAN BE EXEMPT FROM U-VALUE d. PIER BLOCKS MIN.12"X 12"SIZE; RESTING ON CONCRETE PAD MIN. w
<br /> REMOVAL OF INTERIOR WALL OR CEILING FINISHES IS NECESSARY TO REQUIREMENTS. 12"BELOW GRADE.
<br /> >
<br /> INSTALL THE WIRING. k. MAXIMUM SKYLIGHT U-FACTOR =0.50.THE FENESTRATION U-FACTOR
<br /> COLUMN EXCLUDES SKYLIGHTS.THE SHGC COLUMN APPLIES TO ALL e. FOUNDATION WALLS: PROVIDE ONE OPENINGS.11) REBAR TOP AND BOTTOM Q
<br /> CARBON MONOXIDE ALARMS: REQUIRED OUTSIDE SLEEPING AREAS AND ON ALL GLAZED FENESTRATION. AND AT ALL WINDOWS/DOOR LIMIT 4'MAX. BACKFILL. w
<br /> FLOORS,UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES OF THE I. FOUNDATION ANCHOR BOLTS: MIN.1/2"X 10", 6 FT,ON CENTER
<br /> BUILDING. I. OTHER:ADD NOTES FOR ENERGY CERTIFICATE IR401.31i,DUCT LEAKAGE MAX.WITH TWO(2)BOLTS PER PIECE OF PLATE AND AT LEAST
<br /> TESTING IF FURNACE REPLACED IR101.4.3.1j ONE 111 BOLT WITH 12"AT END OF EACH PIECE(REQUIRED FOR CV
<br /> STAIR REQUIREMENTS:(APPLIES TO ALL R-3 STAIRS AND R-2 PRIVATE m. WASHINGTON STATE ENERGY CODE,ALTERATIONS: PROVIDED THE NEW CONSTRUCTION(. O w
<br /> STAIRWAYS): ENERGY USE OF THE BUILDING IS NOT INCREASED,EXISTING CEILING, ALL STRUCTURAL SOFTWOOD PLYWOOD,PARTICLE BOARD,WAFER i Y cD
<br /> WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION MAY BE g BOARD,AND OSB BOARD ARE STAMPED WITH EXPOSURE'I'OR z = Q >
<br /> a. MIN.WIDTH =36" FILLED WITH INSULATION.2X4 WALLS SHALL BE INSULATED TO A
<br /> b. MAX.HEIGHT/RISE =7-3/4"; MIN.TREAD RUN=10" MINIMUM OF R-15. 'EXTERIOR'. 0 w } -
<br /> in O J x w
<br /> a MIN.HEADROOM= 6'8" h, WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L w O o w
<br /> d. HANDRAIL 34"-38"ABOVE TREAD NOSING(RETURN ENDS) FOUNDATION LOCATION:PROPERTY CORNERS MUST BE ACCURATELY APPLIANCE ENERGY CONSERVATION ACT.ASHRAE STANDARD
<br /> e, HANDRAIL GRASP DIMENSION:MIN.1-1/4",MAX.2" DETERMINED AND INDICATED ON SITE FOR FOUNDATION INSPECTION,A 90A-1980 INSULATION TO R-16 OR R-10 PAD IF LOCATED OVER Q r Q w
<br /> I. WINDING STAIRS: SURVEY MAY BE REQUIRED. FENCE LOCATIONS WILL NOT BE ACCEPTED AS UNINSULATED SLAB. -
<br /> 1. MIN. TREAD RUN AT NARROWEST POINT=6" ESTABLISHING PROPERTY CORNERS. i. INSULATE HOT AND COLD WATER PIPES TO R-3 IN UNHEATED
<br /> 2. MiN. TREAD RUN 12"FROM NARROWEST POINT= 10" AREAS.
<br /> g. SPIRAL STAIRS: GARAGE-DWELLiNG FIRE SEPARATION j. SHOWER REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2.5 GPM O J
<br /> 1.SMIN.TA CLEAR WIDTH 26" A. 1-3/8 SOLID-CORE WOOD,1-3/8"SOLID OR HONEYCOMB STEEL,OR 20 k. WOOD STOVES AND FIREPLACES HAVE TIGHT FITTING DOORS, W O
<br /> 2. MIN. WALKINGALK RUN AREA12"FROM NARROWEST POINT =7-1/2"/ MIN. RATED GARAGE/DWELLING DOOR EQUIPPED WITH A SELF-CLOSING OUTSIDE COMBUSTION AIR DUCTED TO FIREBOX WITH ACCESSIBLE Q
<br /> ii
<br /> RISER HEIGHT= 9-1/2" DEVICE. DAMPER,MIN 6 SQ IN FREE VENT AREA, TIGHT FITTING FLUE 0 06 W
<br /> MAX.M.X. HEADROOMR HEIGHT
<br /> =6'6" B. MIN.1/2"GYPSUM WALLBOARD AT GARAGE WALLS AND 5/8"TYPE X DAMPERS REQ'D. Z ..„ =
<br /> GYPSUM BOARD CEILING SEPARATING GARAGE FROM DWELLING IF I. ALL GAS AND OIL COMBUSTION APPLIANCES HAVE A DIRECT VENT > U
<br /> APPLICABLE,
<br /> OR FORCED DRAFT VENTING.
<br /> < >O (n
<br /> CEILING HEIGHT IN ADDITIONS AND ALTERATIONS(SEATTLE) C. MIN.1/2"GYPSUM WALLBOARD WRAPPING POSTS,BEAMS AND WALLS m. RECESSED LIGHTS ARE I.C. RATED,DOUBLE WALL CAN LIGHTS OR
<br /> a. MIN.7'0": FOR NEW CONSTRUCTION OR ADDITIONS SUPPORTING THE DWELLING ABOVE THE GARAGE iF APPLICABLE. •
<br /> W a
<br /> b. MIN. 6'4": IF BUILDING WAS IN EXISTENCE PRIOR TO 10/17/79(SEE DR WITHIN SEALED WPGWB BOX-IN. Z
<br /> 23-2008 FOR SPECIFICS). WASHINGTON STATE ENERGY CREDIT CALCULATION: Z
<br /> c. ROOMS WITH SLOPED CEILINGS REQUIRE MINIMUM CEILING HEIGHT IN 1. 0 SF OF NEW HEATED FLOOR AREA.0 CREDITS REQ'D.
<br /> 1/2 OF THE AREA.(PORTIONS OF THE ROOM WITH CEILING HEIGHT
<br /> LESS THAN 5 FT.DO NOT COUNT IN TOTAL AREA).
<br /> INSULATION:
<br /> 1. FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING MEMBERS. _
<br /> 2. ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED °+.R
<br /> INSULATION, INCLUDING ALL CAVITIES ISOLATED DURING FRAMING, Joe No. 1.171-:2173
<br /> WIRING,LAND PLUMBING.
<br /> 3. ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID BOARD HALFSCALE 11x17
<br /> INSULATION BEHIND THEM.
<br /> FULL SCALE 22x34
<br /> 4. UNDER-FLOOR INSULATION IS SUPPORTED BY LATH,TWINE,OR OTHER SHEET OF 1
<br /> NON-COMPRESSING MEANS.
<br /> 5. ATTIC ACCESS 15 BAFFLED,WEATHER-STRIPPED AND INSULATED. A1 . 1