My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020 LAKE HEIGHTS DR CINGULAR WIRELESS ANTENNA 2019-03-28
>
Address Records
>
LAKE HEIGHTS DR
>
2020
>
CINGULAR WIRELESS ANTENNA
>
2020 LAKE HEIGHTS DR CINGULAR WIRELESS ANTENNA 2019-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2019 7:44:50 AM
Creation date
3/28/2019 7:44:48 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2020
Tenant Name
CINGULAR WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDING KEYED NOTES <br /> QEXISTING GROUND BUSS BAR,TYP. <br /> at&t <br /> --_--' Your world. Delivered. <br /> PROPOSED H-FRAME EXTENSION <br /> =PLANS PREPARED BY: <br /> <> <br /> EXISTING#2 STRANDED GREEN INSULATED COPPER GROUND LEAD FROM <br /> <5 GROUND BUSS BAR TIED INTO THE EXISTING GROUNDING SYSTEM. ��. Ea <br /> NIINE a <br /> • f >PROPOSED LUG GROUND CONNECTION TO EQUIPMENT.SEE DETAIL 9/E-1.1 18928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> PROPOSED LTE TRIPLEXER(TYP OF 6) �/ WOODINVILLE,WA 98072 <br /> PHONE:426487.1732 <br /> W W W.CORNERSTONE-ENGR.COM <br /> =PROJECT INFO: <br /> I PROPOSED WCS RRH(TYP OF 3) PROPOSED#2 STRANDED GREEN INSULATED COPPER GROUND LEAD FROM WA6981 <br /> `°♦,� 1 EQUIPMENT TO GROUND BUSS BAR. <br /> �° �° », i SILVER LAKE RELO <br /> o.o V <br /> ,o � <br /> (E)700MHz RRH(TYP OF 3) A.�Q`°. l I <br /> 2020 LAKE HEIGHTS DRIVE <br /> 1 EVERETT,WA 98208 <br /> t,,,4OJ �, <br /> SNOHOMISH COUNTY <br /> I I F <br /> ISSUED FOR: <br /> l� �LL CONSTRUCTIONi(E)SITE SUPPORT CABINET I I / <br /> Ld _REV::DATE:—ISSUED FOR: BY.. <br /> `o'�o . i / / GROUNDING NOTES <br /> -1 to� I / / <br /> + �O\� ` t / `/ 1. ALL DETAILS ARE SHOWN!N GENERAL TERMS.ACTUAL INSTALLATION AND <br /> (E)UTILITY H-FRAME <br /> _ _� q/ // / / CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. <br /> Q04-20-18 FINAL JRF <br /> � ' / / // / 2. GROUND ALL ANTENNA BASES.FRAMES,CABLE RUNS,AND OTHER METALLIC <br /> \� A� // /�/ // REPLACEMENT DUAL 825/66 RRH(TYP OF 3) COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED <br /> ,, „ / /////ii / BUS BARS.FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR p 04-09-18 PRELIMINARY JRF <br /> •� / //,/ // GROUNDING REQUIREMENTS.GROUND COAX SHIELD AT BOTH ENDS AND EXIT <br /> �/ / /, / FROM TOWER OR POLE USING MFR'S PRACTICES. rDRAWN BY:=CHK.: APV.: <br /> �4c --'' ///�/ / L JRF I MWO I MWO <br /> v�' - �,/// 3. ALL GROUND CONNECTIONS SHALL BE CADWELD.ALL WIRES SHALL BE <br /> tlt �� moi' CURRENT ISSUE DATE: <br /> 4,....., <br /> �Alt "=--.7,-.3--;:-, COPPER RO N(THWN.ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE <br /> y -^ ' ABOVE GROUND. L 04-20-18 <br /> �r Att <br /> �'+:1t 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE.GROUNDING AND _LICENSURE <br /> OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT&T WIRELESS,LLC. <br /> REPRESENTATIVE. <br /> OS L!;y <br /> 5. REFER TO DIVISION 16 GENERAL ELECTRIC:GENERAL ELECTRICAL PROVISION 41--of iyQe <br /> AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. Q c y¢,. <br /> I4. <br /> 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM.AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT&T <br /> O WIRELESS,LLC.REPRESENTATIVE,PRIOR TO INSTALLATION OF GROUNDING <br /> bhYga� �' If<</ <br /> SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING f► <br /> 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES =JURISDICTIONAL APPROVAL: <br /> © INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. <br /> •• .• <br /> (E)613 CONDUIT(TYP) <br /> =PROPRIETARY INFORMATION: <br /> �—i <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> LEGEND IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH IS RELATED TO NAMED CUENT IS <br /> STRICTLY PROHIBITED. <br /> SYMBOL DESCRIPTION —DRAWING TITLE: <br /> NOTE: <br /> O GROUND INSPECTION WELL 7 1 <br /> SCHEMATIC GROUNDING PLAN <br /> ALL GROUNDING WIRE RUNS AND <br /> CONNECTIONS,BOTH ABOVE AND 0 COPPER GROUND ROD <br /> � , DRAWING NUMBER: <br /> BELOW GRADE,SHALL BE LOCATED I'V „, [ <br /> fig COMPRESSION LUG "`�� <br /> INSIDE OF THE LEASE AREA LINE. ,_1 J 0 <br /> - PLAN NORTH A CADWELD CONNECTION ---="�--�- _ <br /> SCHEMATIC GROUNDING PLAN SIDE SPLICE CADWELD <br /> ..: ...,�. .«v : . <br /> 22x34 SCALE:1”=1'-0" 111x17 SCALE.1 FIELD VERIFY&TIE INTO EXISTING GROUNDING SYSTEM CEI JOB NUMBER: LTE 3C-4C 17-09264 <br />
The URL can be used to link to this page
Your browser does not support the video tag.