Laserfiche WebLink
CENERAL NOTES <br /> ------ <br /> �-o-------------- o � <br /> THIS �LECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE � j <br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL � � <br /> CONTRACTOR�S DESIGN SHALL BE APPROVED BY THE OWNER AND SHALL � � <br /> CONFORM TO THE APPL(CABLE ELECTRIC CODE REGARDLESS OF WHAT IS Deck � � <br /> SHOWN ON TNfS DRAWING. <br /> I �� I ��: <br /> � <br /> METER CENTER LOCATIONS SHALL BE COORDINATED WITH THE ARCN(TECT. DRYER � � � \ � ` � <br /> 1'�VENT � 3 1 ; � E� :� � i� � ; � � .; <br /> NlGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHALL � � —�— <br /> MOUNTED NOT LESS THAN 36 INCHES ABOVE FLOOR. ELECTRICAL AND TV I , � ��- � � � WH . � ; <br /> COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 � � � <br /> INCNES ABOVE FLOOR. --------�o�bFV�C��------- � � ` �� � � � I � � C S : <br /> � CEILING HEATER ���� � � F � I ` � �'� ° "�' <br /> � TEL I � � 1250W ELEC i���� � �. � � '�� �G�Y�CC�� �p�, $�19#�r `��Qr��:� <br /> OUTLETS, SWITCHES, TELEPNONE AND TU, ETC. BOXES IN PARTY WALLS OF I cEiuNc NEarER , - . <br /> ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN , � j , � l � I� � , �, , �C4r�C�qr����Np��titg��tt �$Q�� ; <br /> TNE ADJACENT UNlT. NO TWO ADJACENT UNITS SHALL NAVE SUCH BOXES � i � � �.` �.� � � T� � I , �,4,���������} F,��565gtf�2tk� � <br /> 1N THE SAME STUD SPACE. BOXES SNALL BE SEPARATED HOR(ZONTALLY � I -.-.- - � �SMURF , , ��� ��,� ���������������� ,� <br /> BY 24 . i �P i � � i i ti \ aTUBE � I .;�. ,�. ._.. <br /> � <br /> INDIVIDUAL ELECTRICAL OUTLET BOXES SNALL BE OF STEEL OR OTHER ' \ `.\ 4 j ' I I j �� T� TV ��� ' �� � <br /> APPROVED MATERIAL AND SHALL NOT BE GREA�ER THAN 16 SQUARE Bedroom . , l , � � L�ving � FIREPLACE i <br /> INCHES IN AREA: ' �` � � ' � � �` � � �� ' 5052 REGISTERED <br /> I Sp I , � 0 � � ARCHITEGT <br /> TNE WATER HEATERS SHALL BE STRAPPED PER IRC P2801.7 AT A POINT � � � f � � ' � � �J <br /> WITHIN TNE UPPER 1/3 AND TNE tOWER 1/3 OF ITS VERT(CAL DIMENSION. STACK �� +48 I � /fJ <br /> THE LOWER STRAP SHALL BE NOT LESS THAN 4" ABOVE ANY CONTROLS. � TNERMOSTAT � � � ` � � ; �f� <br /> SWITCH W/D � � RQBERT E. WEIBLE <br /> WATER HEATERS SHALL BE PROVIDED WlTH A PRESStJRE/TEMPERATURE � T ��=; , �. / \ � � STATE OF WASHINGTON <br /> RELIEF VALVF THAT IS CONNECTED TO A DRAIN LINE. THE pRAW LINE � � ' � � � iSTACK�. ' , � � <br /> SNALL BE DIRECTED TOWARD TNE GROUND AND TERMlNATE AT A PO(NT NO ' ��.�h ' � �._ _T�lE'RMOSTAT � �. <br /> » � <br /> LESS THAN 6 AND N0 MORE TNAN 24' pBOVE THE GROUND. , ' L WNF�. , � _ ___ ___ ,___ ___ ._& SWITCH__ ----- � , � , <br /> _ <br /> yTR � . <br /> r- -i i <br /> . <br /> SMQKE DETECTORS SHALL BE EQUIPPED WITH A QATTERY BACK-UP, SNALL , � i � � ' � � , i ' �== =------=- ==----- = = � g � , �, �.\ , � <br /> EMIT A SIGNAL WHEN BATTERIE� ARE LOW, SHALL BE PERMANENTLY NARQ i � � � �/ . � , _ � t � ' I y <br /> WIRED AND WITHQUT A DtSCONNECTING SWITCN OTNER TNAN THOSE , ; , � � ' � � � ' , i � � <br /> REQUIRED FOR OVERCURRENT PROTECTION, AND SHALL SO�1ND AN ALARM ' i o `' ; L---�� � ' I � '" `' ' j ' � , <br /> AUDIBLE 1N ALL SLEEPING AREAS OF TNE DWELLING IN WHICH THEY ARE � W � I � � � � .� <br /> C ED. ' � � � � � ' �--- ` � <br /> LO AT � 1250W ELEC I i--" -�- ''- <br /> i i 0 GFCI �r I i CEILING HEATER / D�nI� i I � � � <br /> �---------- 'a <br /> E N E R G Y I�4 T E S I� i PENDANT � � I ! i----------- � �; <br /> i i � � � � � � i�---------__ � .. <br /> SEE ENERGY �VOTES ON SNEET A1 & D5. � � � �� � _ � <br /> M. Bath � 4�-0�� , � � <br /> � �----------- <br /> _ <br /> � <br /> WATER NEATER SHALL BE FUELED BY GAS AND NAVE A MINIMUM EF OF � � ' `^ <br /> i i 1 0� i <br /> / ---------- Z cn � <br /> 0.82. � F SD � �. d- <br /> ' VTR� � �. ' � , ---- -,- --- , c� ,� <br /> � <br /> .� <br /> � �. TO ` i � GHIME Garage ;' � � ---------- ' o Q � <br /> HOT AND COLD WATER HEATER PIPES W UNCONDITIONED SPACES SHALL BE �_ � � I <br /> I N S U L A T E D W I T H R-3 I N S U L A T I O N W H I C H H A S A F L A M E S P R E A D O F 2 5 O R � � �E�Q w � __�_�-- _________ � � W = � <br /> � , �. � , .... . .... �.. � � � c3 � <br /> LESS. �; , �: � � ... ........................ � � � � � <br /> 39 � � � � , � � W � <br /> =--------------------�-�--_-____ <br /> � GF T \ \ �. � �REMQVED � � � ' � E�EC PANEL �-- ----- � � � � <br /> . <br /> VENTILATION NOTES � � � I LOW VOLTAGE � �+46" \� \� ; f O O � <br /> � i j � � �PANEL � � ��� \ � � � AT � i � � � � <br /> VENTlLATION: SEE NOTES ON COVER SHEET. � � �' - ' / � � , � � � � CEILING � � � �" <br /> i TEL �� , � � `-=.,.,./ � � •� � i � � .1 i o � � � <br /> �� � � � o � <br /> ALL EXHAU3:3 DUCTS SNALL BE RIGID METAL, AND SHALL BE �ITTEQ WITH A ! i � � ' + � _ � � <br /> � � <br /> TIGNT FITTING BACKDRA�T DAMPER CAPABLE OF CLQSING WNEN THE FAN IS � ° _. - <br /> � / ! � � I I TjLc`�� , _ � I � � I j� � \ / � � � � <br /> NOT IN USE. � � r� i ' �j �� � � ` j� ,� \� , � I � c' z � <br /> DUCTS IN UNNEATED SPACES INCLUDWG ATTICS SHALL BE lNSULATED TO A � I \" � I <br /> � � ( � ( 3 � / � \'� �, 2 / I <br /> MIN(MUM OF R-8. i �Fp � ' i , � <br /> , � � <br /> � I � � K�tChen ' j� \ \��.� � 250W � <br /> TOP FLOOR EXNAUST FANS SHALL VENT TNROUGH ATT1C. ; F a E(�EC � � <br /> � � Master j � � � t a� � � � PREWIRE LOW � PB BA OA � � � . <br /> i � 1250W ELEC PUWr VOL�TAGE WIRE � o ,,� <br /> QRYER EXNAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" QPENING ON � Bedroom I I � i- CEILWG HEATER ' I / _ ____ ___ � <br /> i FOR GARAGE � N <br /> THE EXHAUST HOOD. THE DRYERS DUCTS SNAL� BE GALVANIZED STEEL OR ' � ' ' ' I+46' � � � DOOR OPENER \ , � 6 0 <br /> ALUMINUM, MfNfMUM 0.016 TNICK. THE DRYERS SHALL BE GENERAL T� I � j � / ^ � I & ELEC. EYES "'pB � N � <br /> ELECTRIC. DRYERS SNALL BE 1NSTALLED ACCORDING TO MANUFACTURER S ' � ' � � ' <br /> INSTAL,LATION INSTRUCTIONS ON SITE. � ' � pW � +as" � � -��--- <br /> 1250W ELEG , � , � 48^ � °�'' -.� i � � � i <br /> CEILING HEATER W I I I � �t <br /> WINDOW OUTDOOR AIR INLETS SNALL PROVfDE TNE EQUIVALENT OF 4 SQ. �, � � - -�- - � � <br /> IN. OF NET FREE AREA. '---�- -----------� � � <br /> / Q � <br /> .. � <br /> ----T��. ------------------------ J :' o <br /> o N <br /> PNOTOCELL Q., Q <br /> � � <br /> � � <br /> UPPER LEVEL MAIN LEVEL LC)WER LEVEL U � <br /> � <br /> � I-T E UTILITY PLAN � � I�T UTILITY PLAN U I�I I-T E UTILITY PLAN � m � <br /> a <br /> � L E C T R I C A L L E C E N D ��4"=1'-Q" 1/4"=1'-0" BUILDING CFEFG � a � <br /> 1/4"=1'-0" W � <br /> o � <br /> ...� <br /> � DUPLEX RECEPTACLE OUTLET DIRECTIONAL CEILING W <br /> MOUNTED LIGHT <br /> � DUPLEX RECEPTACLE OUTLET <br /> SPLIT WIRED (SWITCN TOP HALF) � CEILING MOUNTED LIGHT � <br /> �� DUPLEX RECEPTACLE OUTLET � ! <br /> a il <br /> MICROWAVE � RECESSED CEILING LIGHT; `" " <br /> � IC RATED - SEE 12/Dl � • <br /> � SINGLE RECEPTACLE OUTLET ` <br /> T <br /> 208v (R: RANGE, D: DRYER� �} WALL MOUNTED LIGHT <br /> Q JUNCTION BOX ' <br /> �"----�� DOUBLE TUBE FLUORESCENT � <br /> � <br /> � TECN POftT CEILING MOUNTED LIGHT � <br /> TEL.� TELEPNONE JACK -�--- CEILING MOUNTED TRACK LIGHT � <br /> TV TELEVISION JACK � � � <br /> � HEAT LAMP, EXHAUST FAN � � <br /> � SWGLE POLE SWITCH COMBINATION RECESSED CEILING Q <br /> FIXTURE - 250W LAMP, 50 CFM � <br /> �3 TNREE WAY SWITCH S E 15/DONES, 4" ROUNQ DUCT. � � O <br /> DIM.� DIMMER SWITCH ������::� BEAftiNG WALL - SEE NOTES � u � U <br /> r TIMER SWfTCH THIS SHEET REGARDING BOXES � � .�.� <br /> � AND FlRE-RATED WALLS <br /> N <br /> � RECESSED CEILWG EXHAUST FAN � METER CENTER � � � � <br /> 50 CFM MIN, 3 SONES MAX, � � � <br /> 4" ROUND QUCT. SEE 15/D1 � ELECTRICAL PANEL � � � � <br /> aeN ELECTRIC BASEBOARD � <br /> � MICROWAVE OVEN/RANGE HOOD � HEATER � L <br /> L-MW-J COMBINATION, 100 CFM, 3 SONES � � � O <br /> � o � Z <br /> SMOOTN DUCT. OT TNERMOSTAT <br /> H RECESSED HEAT LAMP - � SMOKE DETECTOR ~ W . <br /> � '�"i � <br /> NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP ..� <br /> CEILING FIXTURE. SEE 12/D9 � � <br /> CARBON MONOXIDE � <br /> ,�j PHQTOCELL SAFETY SENSOR ALARM/SMQKE DETECTOR � � <br /> �, <br /> _1_. C� a <br /> ❑ TECH PANEL � AUDIBLE SPRWKLER � <br /> SFA FLOW ALARM <br /> r <br /> � RECESSED CEILING WNOLE WINDOW WiTH OUTDOOR <br /> WHF HOUSE EXHAUST FAN �� A!R 1NLET � <br /> 80 CFM MlN., 12Q CFM MAX., <br /> 1.5 SONES, 6" ROUND DUCT <br /> ��B PUSN BUTTON <br /> � 1ob No.: 13-47 <br /> � <br /> � <br /> vTR VENT THROUGN ROOF � Sheet No.: • <br /> z <br /> � <br /> �� <br /> Sheet Order: � �i � F R E S � � � <br /> T <br />