. , <br /> CENERAL NQTES � �' <br /> r-----------------------, - <br /> ' ° ° ' � <br /> TNIS ELECTRICAL PLAN IS TNE ARCHtTECT'S SUGGESTED LAYOUT. THE � 1 <br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL I � <br /> CONTRACTOR'S DESIGN SNALL BE APPROVED BY TNE OWNER AND SHALL � � <br /> CONFORM TO THE APPUCABLE ELECTRIC CODE REGARDLESS QF WHAT IS Deck � f <br /> SHOWN ON TH1S DRAWING. � C <br /> I i � <br /> a <br /> METER CENTER LOCATIONS SHALL BE COORDINATED WiTH THE ARCHITECT. DRYER � �' i �� j ��,' <br /> HIGNEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHALL T�VENT � � ; �. ' ' <br /> MOUNTED NOT LESS THAN 36 INCHES ABOVE FLOOR. ELECTRICAL AND � 1 3 _.i � � WH � � .�, � �"' p � � t <br /> COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 � TV � : <br /> INCHES ABOVE FLOOR. <br /> � � � � � ?� � ,� � �; <br /> � --------�a�ow�c��------- � � , , <br /> � CEILING HEATER i � � <br /> I <br /> OUTLETS, SWITCHES, TELEPHONE ANd TV, ETC. BOXES IN PARTY WALLS QF TEL � I 1250W ELEC F y'�. � i E � '� ': <br /> � CEILING HEATER i � � � ������-q� ���, 'y�'���"�`�(� : <br /> ONE UN1T SHALL BE IN DIFFERENT STUD SPACES TNAN THOSE IN � I � <br /> THE ADJACENT UNIT. NO TWO ADJACENT UNITS SHA�L HAVE SUCH BOXES � I � ' �' _ � ' � �� � Kfrklant�,t�a��t,trtgt�n 4$Q33. �� ' <br /> !N TNE SAME STUD SPACE. BOXES SHALL BE SEPARATED HORIZONTALLY � j � j ���._ ��' � h T� �. �� � ���,���7��`���f 42�65�3 12�8 .;; � <br /> Y <br /> ,� � I , - - � � SMURF <br /> \ ��h w�s�v���br�r€�d���t�c��i' ,� <br /> 4 . FP � � � � � \�TUBE � ' <br /> - . .<. _.<.-; <br /> : . . . :. , � <br /> INDIV)DUAL ELECTRICAL OUTLET BOXES SHA(�L BE OF STEEL OR OTHER ' � �. � j ' �� � � �0 ' / , \� , <br /> APPROVED MATERIAL AND SNALL NOT BE GREATER THAN 16 SQUARE Bedroom�. � 1 , j � Living � FIREPLACE Tv � � I <br /> INCHES IN AREA: � � � � , I � � � � � <br /> \ I \ I � ` 5052 REGISTERED <br /> THE WATER HEATERS SHALL BE STRAPPED PER IRC P2801.7 AT A POINT ' STACK �� � i� � ' � � I ARCHITECT <br /> WITHIN THE UPPER ? 3 AND THE LOWER 1 3 OF ITS VERTICAL DIMENSlON. I +4a f � <br /> THE LOWER STRAP HALL BE NOT LESS T AN 4" ABOVE ANY CQNTROLS. THERMOSTAT � i <br /> WATER HEATERS SHALL BE PROVIDED WlTH A PRESSURE TEMPERATURE SWITCH !W�D ' � �..� ' � � � <br /> � � T � � � � � ROBERT E. WEIBLE <br /> RELIEF VALVE THAT IS CONNECTED TO A DRAIN LINE. THE DRAW LINE � ; I , j �.\ iSTACK`.\ � � STATE OF WASHINGTON <br /> SHALL BE DIRECTED TOWARD TNE GROUND ANQ TERMINATE AT A PO(NT NO � Ba,�h � �. T�lE'F2MOSTAT � <br /> LESS THAN 6" AND N0 MORE THAN 24" AB�VE THE GROUND. , i L WHF�. , � - _ & SWITCH___ ----- � � '. <br /> r---� i <br /> i <br /> SMOKE DETECTORS SNALL BE EQUIPPED WITH A BATTERY BACK-UP, SHALL � �, yTR � � � � <br /> _______________ ______________ ._ _ _ <br /> . <br /> � � �' � '�._. � � � 3 4 � i ' \ i � <br /> EM1T A SIGNAL WHEN BATTERIES ARE LOW, SHALL BE PERMANENTLY HARD ; � <br /> WIRED AND WITHOUT A DISCONNECTiNG SWITCH OTHER TNAN THOSE '� ; , � �� � , � � - � ^ � � Q � � <br /> REQUIRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN AL.ARM ' ' o � ; �-__� ' � I �^ <br /> � � I � � �. i i i a, <br /> AUDIBLE IN ALL S�EEPlNG AREAS OF THE DWELLING IN WHICN THEY ARE ,� <br /> LOCATED. <br /> w � j j � / I <br /> � , , � <br /> i 3 \ j 1250W ELEC � i ---- i .c—" <br /> i � � GFCI i CEILING HEATER i ^ T _ L <br /> __ _ _ <br /> � � Dining ! � _ <br /> ENERCY NC.�TES � ° ' I � ' � -------- ! � <br /> � <br /> i i � � i PENDANT �I I � �----------- � nv <br /> SEE ENERGY NQTES ON SHEET A1 8c D5. � �_ _______ _ � <br /> M. Bath ` , 4'-0" , , ; � <br /> WATER HEATER SHALL BE FUELED BY GAS AND HAVE A MINIMUM EF OF � , <br /> � <br /> �------------ <br /> - <br /> � � <br /> , <br /> 0.82. L F S� j � � / ---------- � cn � <br /> _ . <br /> � � d- Z cn m <br /> HOT AND COLD WATER HEATER PIPES IN UNCONDITIONED SPAGES SHALL BE ' VTR� � `.� T� � ' \� CHIME � Garage ! ---------- � O � � <br /> _ _ <br /> � <br /> INSULATED WITN R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR � �� BF��w ` � �. � G � � z L <br /> � ---------- — <br /> ae <br /> LESS. ' ; � � ' � � --,--------�' �.---------,:--- ' , � <br /> T � � -- --- -: -- -- � � � <br /> ' 39 � � �A. � � � a <br /> � _ � ... �.� �. � <br /> .� <br /> ' �� �F V �V �. � �REMO�VED � �. ' � EZEC PANEL --- ----- � � � � <br /> VENTIL�T�ON NOTES � �� � I � �p�NELOLTAGE , �+4�" � ��� ��� ; o O � <br /> VENTlLATION: SEE NOTES ON CQVER SHEET. ��� � � ��-�� � � � � � � � � CEILWG � � � � � <br /> � TEL �.�. / / � _ �-� �. I ' I � 1 I, ' � <br /> ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE F(TTED WITH A � � � � ' I � , � ' � �� � ' o � o a' <br /> + � � o d- � <br /> TIGNT FITTING BACKDRAFT DAMPER CAPABLE OF CLQSING WHEN THE FAN 1S , j j f � , ' � �� � , � � � � � � v <br /> NOT IN USE. i I T L � � � 1 <br /> I 1 I � i �. �. � <br /> DUCTS IN UNHEATED SPACES INCLUDING ATTICS SNALL BE INSULATED TO A � , � ! i ' I � � i �.\ �.� � 2 t�'y N � Z O <br /> MIN(MUM OF R-B. � I ; � � � �. �i <br /> , � CFP i � � It Kitchen ' ' jJ 1\ \ �.�. � 250W � <br /> TOP FLOOR EXHAUST FANS SHALL VENT TNROUGH ATTIC. E�EC I <br /> � ' Master � � � F � � � � PREWIRE LOW PB BA OA d � � <br /> » » � � , 1250W ELEC � � � ' +— � <br /> DRYER EXHRUST DUCT SHALL BE 4 RIGID METAL W1TH A 4 OPENlNG ON , , � Bedroom j � , ` CEILING HEATER P�WC. � VOLTAGE WIRE � o � <br /> THE EXHAUST NOOD. THE DRYERS DUCTS SHALL BE GALVANIZED STEEL OR _ � FOR GARAGE � - ---- --- �- c� <br /> ALUMINUM, " � I �+�p � ' � DOOR OPENER �. ' - °' o <br /> MINfMUM 0.016 TNICK. THE DRYERS SHALL BE GENERAL j � ' � & ELEC. EYES "'F' � � <br /> ELECTRIC. DRYERS SHALL BE INSTALLED ACCORDING TO MANUFACTURER S � TV � � � � � p�� N <br /> INSTALLATION INSTRUCTIONS ON SITE. � 1 pW I +as° , -�- -- <br /> 1250W ELEC � � 46" � ��. —.� I I � <br /> WINDOW OUTDOQR AIR INLETS SHALL PROVfDE THE EQUIVALENT OF 4 SQ. ceiurvc HEarER ��.' � � � � � � <br /> IN. OF NET FREE AREA. `� � �' I � � - - - � I <br /> �._ _.--------------� Z co <br /> l Q � <br /> .. , <br /> ------------------------------- � o <br /> TO � J o c� ' <br /> PHOTQCELL W � � o <br /> � � <br /> _ a <br /> UPPER LEVE� MAIN LEVEL LOWER LEVEL � V—�, <br /> U N I T E UTI LITY PLAN U N I T E UTI LITY PLAN U N I T E UTI LITY PLAN � m � <br /> E � � � � 1� � � � �„ � E �j E � � 1/4"=1'-0" 1/4"=1'-0" 1/4"=1'-0" BUILDING GFEFG � V 3 � <br /> W a � <br /> � � � <br /> � DUPLEX RECEPTACLE OUTLET DlRECTIONAL CEILING (,JJ <br /> MOUNTED LIGHT <br /> � DUPLEX RECEPTACLE OUTLET � <br /> SPLIT WIRED (SWITCH TOP HALF) � o <br /> CEILING MOUNTED LIGHT � <br /> M� DUPLEX RECEPTACLE OUTLET �; r- <br /> � u <br /> MICROWAVE � RECESSED CEILING LIGHT; � <br /> !C RATED - SEE 12/D1 <br /> � SINGLE RECEPTACLE OUTLET <br /> � <br /> 208v (R: RANGE, D: DRYER) -�} N/ALL MOUNTED LIGHT <br /> Q JUNCTION BOX <br /> (Z�'---,--� DOUBLE TIJBE FLUORESCENT '�"� <br /> � T�CN PORT CEILING MOUNTED LIGHT � <br /> TEL.� TELEPHONE JACK � <br /> � CEILING MOUNTED TRACK LIGFiT � <br /> TV TELEVISION JACK � HEAT LAMP, EXHAUST FAN � � <br /> � COMBlNATiON RECESSED CEILING O Q <br /> SINGLE PpLE SWITCH FIXTURE - 250W LAMP, 50 CFM � � <br /> �3 THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT. <br /> SEE 15/D1 � _ � <br /> DIM.� Q�MMER SWITCH ��������� BEARING WALL - SEE NOTES W Q Q U <br /> THIS SHEET REGARDING BOXES <br /> �T TIMER SWITCH AND FIRE-RATED WALLS � � � N <br /> � RECESSED CEILING EXNAUST FAN � METER CENTER � � N � <br /> 50 CFM MIN, 3 SONES MAX, — O � � <br /> 4" ROUND DUCT. SEE 15/D1 � ELECTRICAL PANEL , <br /> MICROWAVE OVEN RANGE NOOD 8� ELECTRIC BASEBOARD � _ ,��^ 'i � <br /> � V � � <br /> LMw-� COMBINATION, 100 CFM, 3 SONES NEATER � 0 <br /> W � > Z <br /> SMOOTH DUCT. �T TNERMOSTAT <br /> � RECESSED HEAT LAMP - � SMOKE DETECTOR .}.+ u1 O <br /> �t" NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP <br /> CEILING FIXTURE. SEE 12/D1 � CARBON MONOXIDE �� �� <br /> � <br /> PHOTOCELL SAFETY SENSOR ALARM/SMOKE DETECTOR = � <br /> � � <br /> ❑ TECH PANEL � AUDIBLE SPRINKLER C� O. <br /> SFA FLOW ALARM � <br /> r <br /> � RECESSED CEILING WHOLE E�� WINDOW WITH OUTDOOR • <br /> WHF HOUSE EXHAUST FAN AIR INLET a <br /> 80 CFM MIN., 120 CFM MAX., <br /> 1.5 SONES, 6" ROUND DUCT <br /> �PB PUSH BUTTON <br /> , <br /> � 1ob No.: 13-47 <br /> VTR VENT TNROUGH ROOF �; <br /> �- Sheet No.: <br /> z <br /> � U3� :. <br /> Sheet Order: A B U F R E S � � � <br /> _ <br />