Laserfiche WebLink
_ _ . . . _ _ <br /> � <br /> B � R � R <br /> architecture <br /> Architect of Record: <br /> BRR architecture,Inc. <br /> Kansas ciry � 6700 Antioch Plaza <br /> � � . Bentonviue SuitO 300 <br /> Phoenix Merriam,KS 66204 <br /> . - . � San Francisco <br /> Phlladelphia <br /> � . . . nna�ea Te1:913-262-9095 <br /> Miami , Fax:913-262-9044 <br /> Consultants <br /> MEP Engineer of Record <br /> Randall A. Nelson, P. E. <br /> 14817 West 95th Street <br /> � Lenexa, Kansas 66215 <br /> MECHANICAL LEGEND W/ PLUMBING� W/0 HYDRONICS PROJECT GENERAL NOTES Phone 9�s 322 5�50 <br /> � SYMBOLS SYMBOLS(cont'd) ABBREVIATIONS 1. SEE ALSO INDIVIDUAL SHEEf GENERAL NOTES. <br /> � SUPPLY AIR UP �1 GAS COCK AFF ABOVE FINISHED FLOOR FPM FEET PER MINUTE NTS NOT TO SCA�E 2. ALL WORK SHALL COMPLY WITH CURRENT FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES AS WELL AS THE <br /> CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL REPORT ANY CONFLICTS TO THE ENGINEER AS SOON AS THEY ARE <br /> � GATE VALVE AD AREA DRAW FPS FEEf PER SECOND OA OUTSIDE AIR DISCOVERED. <br /> SUPPLY AIR UP & THRU copyright Notice <br /> � GLOBE VALVE AG ABOVE GRADE FPWH FREEZE PROOF WA�L HYDRANT OBD OPPOSED BIADE DAMPER 3. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFICATIONS PRIOR TO BIDDING JOB AND DURING � <br /> �-�" CONSTRUCTION. EXCEPT AS OTHERWISE NOTED, THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, & This drawing was prepared for use on a specific . <br /> site contemporaneously with its issue date and <br /> SUPPLY AIR DOWN li`1CI NEEDLE VALVE APD AIR PRESSURE DROP FPYH FREEZE PROOF YARD HYDRANT ORD OVERFLOW ROOF ORAIN LABOR FOR A COMPLETE PROJECT AS SHOWN IN THE DRAWINGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS it is not suitable for use on a different projed <br /> - CARRY EQUAL IMPORTANCE AND ITEMS LISTED IN EITHER SHALL BE FURNISHED AS IF LISTED IN BOTH. ALSO REVIEW site or at a later time.Use of this drawing for <br /> � PLUG VALVE ASHRAE AMERICAN SOCIEfY OF HEATING, REFRIGERATION, FS FLOOR SINK PD PRESSURE DROP DETAILS AND RISER DIAGRAMS FOR ADDITIONAL ITEMS�INSTRUCTIONS WHETHER SPECIFICALLY REFERRED TO ON PLANS reference or example on another project <br /> � . � � . � requires the services of properly licensed . <br /> SUPPLY AIR BOTTOM TAP "p & AIR CONDITIONING ENGINEERS OR NOT. architects and engineers.Reproduction of this <br /> t�V PRESSURE REDUCING VALVE FSD FIRE � SMOKE DAMPER PH PHASE d�awio9 for re�5e oo aootner Pro�e�t i5 not <br /> � � authorized and may be contrery to the law. <br /> � BD BLOWDOWN DRAW 4. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHOW THE GENERAL INSTALLATION OF EQUIPMENT & MATERIALS IN <br /> RETURN�EXHAUST�OUTSIDE AIR UP /-I VALVE IN PIPE RISER FT FOOT OR FEET PRV PRESSURE RELIEF VALVE � REDUCING VALVE RELATIONSHIP TO STRUCTURE & OTHER TRADES. THEY MAY NOT SHOW EVERY REQUIRED OFFSET, FITTING, ETC. �ssues s�rtevisions <br /> BG BELOW GRADE CONTRACTOR SHALL FIELD VERIFY ACTUAL JOB CONDITIONS AND COORDINATE WORK WITH OTNER TRADES PRIOR TO No. �ATE DESCRIPTION <br /> � (.�°I CHECK VALVE fTR FLUE THRU ROOF PSI POUNDS PER SQUARE INCH BIDDING JOB AND PRIOR TO ORDERING EQUIPMENT, FABRICATION OF MATERIALS, OR STARTING WORK. CONTRACTOR 07/08/15 ADD#1 <br /> RETURN/EXHAUST/OUTSIDE AIR UP BOD BOTTOM OF DUCT SHALL NOT SCALE THE DRAWINGS. <br /> (OI CIRCUIT SETTER GA. GAUGE PSIG POUNDS PER SQUARE INCH GAUGE <br /> 10109l15 ADD#4 <br /> � BOP BOTiOM OF PIPE 5. IT IS TNE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL ITEMS THAT AFFECT OTHER DISCIPLINES WITH <br /> nRETURN/EXHAUST/OUTSIDE AIR DOWN � STRAINER GAL. GALLON(S) RA RETURN AIR THE CORRESPONDING CONTRACTOR AND THE GENERAL CONTRACTOR IF EQUIPMENT, MATERIALS, ETC. OTHER THAN <br /> ------= BTU BRITISH THERMAL UNIT THOSE SCHEDULED & SPECIFIED (PENDING PRE–APPROVAL) ARE FURNISHED. <br /> I I I UNION GC GENERAL CONTRACTOR RAG RETURN AIR GRILLE <br /> � REfURN/EXHAUST/OUTSIOE AIR BOTfOM TAP , BTUH BTUs PER HOUR 6. CHANGE ORDERS WILL NOT BE GRANTED DUE TO LACK OF COORDINATION WITH JOB CONDITIONS AND/OR OTHER ' <br /> � FLOW DIRECTION ARROW GCO GRADE CLEANOUT RD ROOF DRAIN <br /> CA COMBUSTION AIR / COMPRESSED AIR CONTRACTORS. <br /> ��- MANUAL DAMPER � PIPE BREAK GPH GALLONS PER HOUR RLA RUNNING LOAD AMPS 7. MAINTAIN ALL REQUIRED SERVICE, FRESH AIR, & ROOF EDGE CLEARANCES FOR ALI. NEW AND EXISTING EQUIPMENT, <br /> C PIPE CAP CAP. CAPACITY <br /> DUCTWORK, AND PLUMBING VENTS. <br /> � GPM GALLONS PER MINUTE SA SUPPLY AIR <br /> MITERED ELBOW WITH TURNING VANES CO CLEANOUT 8. EXISTING EQUIPMENT, DUCTWORK, & PIPING SIZES AND LOCATIONS ARE SHOWN FOR REFERENCE ONLY. ADJUST <br /> ► PIPE REDUCER HB HOSE BIBB SD STORM DRAIN EXACT INSTALLATION & CONNECTION OF NEW ITEMS ACCORDING TO ACTUAL CONDITIONS. <br /> CFM CUBIC FEEf PER MINUTE <br /> � � RADIUSED ELBOW HP HORSEPOWER SENS. SENSIBLE 9. G.C. SHALL CUT & PATCH FLOOR, WALLS, & ROOF AS REQUIRED FOR INSTALLATION/DEMOLITION OF MECHANICAL <br /> CW COLD WATER (DOMESTIC) SYSTEMS. <br /> LINETYPES I PIPE LABELS HW HOT WATER (DOMESTIC) SIM, SIMILAR <br /> e CONNECT/REMOVE TO EXISTING DB DRY BULB SMACNA SHEET MEiAI. & AIR CONDITIONING CONTRACTORS 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE OF RELOCATED EQUIPMENT AND MATERIALS DURING <br /> DEMO ITEMS HWC HOT WATER CIRCULATING (DOMESTIC) CONSTRUCTION. ITEMS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. <br /> OT THERMOSTAT DN DOWN NATIONAL ASSOCIATION <br /> DOMESTIC COLD WATER IN. INCHES 11. UPON COMPLETION OF THE PROJECT THE CONTRACTOR SHALL PROVIDE AS–BUILT DRAWINGS TO THE OWNER, <br /> OH HUMIDISTAT DWV DRAIN, WASTE, & VENT SP STATIC PRESSURE ARCHITECT, AND ENGINEER SHOWING EQUIPMENT, DUCTWORK, PIPING, ETC. THAT DIFFERS FROM CONSTRUCTION ' <br /> DOMESTIC HOT WATER KW KILOWATT DOCUMENTS AS THEY ARE ACTUALLY INSTALLED. <br /> OS FAN SWITCH E, (E), or EXIST. EXISTING TA TRANSFER AIR <br /> DOMESTIC HOT WATER CIRCULATING LBS POUNDS 12. THE RESPONSIBILITY OF EACH CONTRACTOR IS NOT LIMITED TO THEIR SPECI�'IC DISCIPLINE'S DRAWING SHEETS. REFER <br /> M MOTORIZED DAMPER ACTUATOR EA EXHAUST AIR TAG TRANSFER AIR GRILLE <br /> � SANITARY SEWER / WASTE LOB LEAVING DRY BULB TO OTHER DISCIP�INES' DRAWING SHEETS AS REQUIRED FOR ADDITIONAL INFORMATION/INSTRUCTIONS. <br /> SD DUCT MOUNTED SMOKE DEfECTOR EA. EACH TCC TEMPERATURE CONTRO�S CONTRACTOR <br /> O VENT �WB LEAVING WET BULB 13. FIRE SEAL ALL PENEiRATIONS THRU RATED WALLS. SLEEVE IN ENTIRETY WITH APPROPRIATE SLEEVE MATERIAL. <br /> EAT ENTERING AIR TEMPERATURE T.O.D. TOP OF DUCT <br /> XXX–X EQUIPMENT � PLUMBING FIXTURE TAG Project wame <br /> � _ VENT BELOW FLOOR MAX. MAXIMUM <br /> O PLAN NOTE EC ELECTRICAL CONTRACTOR T.O.P. TOP OF PIPE <br /> A AIR (MEDICAL) MBh 1,000 BTUH w��d5 rin <br /> —� DIRECTION OF AIRFLOW ECO END CLEANOUT TSP TOTAL STATIC PRESSURE MECHANICAL GENERAL NOTES p g <br /> c,a COMPRESSED AIR EDB ENTERING DRY BULB MC MECHANICAL CONTRACTOR nP TYPICAL SUIteS <br /> � FIRE/SMOKE DAMPER o CONDENSATE DRAIN MCA MINIMUM CIRCUIT AMPACITY Signature <br /> FIRE DAMPER ERV ENERGY RECOVERY VENTILATOR V VENT / VOLTS 1. ALL DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS. <br /> � OR � FIRE PROTECTION MFR. MANUFACTURER <br /> FD ESP EXTERNAL STATIC PRESSURE VBF VENT BELOW FLOOR 2. INSTALL BALANCING DAMPERS IN EACH GRILLE�DIFFUSER DUCT RUNOUT NOT BEING PROVIDED WITH OBD AT GRILLE Project Address <br /> c GAS MH MANHOLE (SEE GRILLES, REGISTERS, AND DIFFUSERS SCHEDULE). LOCATE DAMPERS ABOVE ACCESSIBLE CEILINGS. � <br /> � UNDERCUT DOOR EWB ENTERING WEf BU�B VTR VENT THRU ROOF 7707 Broadway <br /> N NITROGEN MIN. MINIMUM 3. UPON COMPLETION OF INSTALLATION OF NEW HVAC SYSTEMS, ALL SYSTEMS SHALL BE BALANCED BY TNE Everett, WA 98203 <br /> � X XXX GRD TAG 'F DEGREES FANRENHEIT W WATER MECHANICAL CONTRACTOR <br /> N2o NITROUS OXIDE MOCP MAXIMUM OVERCURRENT PROTECTION <br /> ' cri FA FRESH AIR W/ WITH 4. TRANSITION FROM DUCT SIZE SHOWN ON PLANS TO EQUIPMENT CONNECTION SIZE AT CONNECTION TO EQUIPMENT. <br /> Z � REVISION TAG oR� OVERFLOW ROOF DRAIN MVD MANUAL VOLUME DAMPER <br /> � w FCO FLOOR CLEANOUT WB WEf BULB <br /> J � ADA COMPLIANT p2 OXYGEN (MEDICAL OR INDUSTRIAL) NC NOISE CRITERIA <br /> � Q OR ��� ROUND FLOOR DRAIN FD FIRE DAMPER / FLOOR DRAIN WCO WALL CLEANOUT <br /> R� REFRIGERANT LIQUID N.C. NORMALLY CLOSED <br /> � � SQUARE FLOOR DRAIN / FLOOR SINK FL or FL ELEV. FLOW LINE ELEVATION WH WALL HYDRANT <br /> W Rs REFRIGERANT SUCTION NFPA NATIONAL FIRE PROTECTION ASSOCIATION � <br /> � <br /> � O OR � FLOOR CLEANOUT FLA FULL LOAD AMPS <br /> yy�p WITHOU � �, <br /> Z Ro ROOF DRAIN N0. NUMBER ��� <br /> � �i WALL END CLEANOUT FP FIRE PROTECTION WPL WEATHER PROOF LOUVER ���� <br /> Z � vac VACUUM (MEDICAL OR INDUSTRIAL) N•0. NORMALLY OPEN �� <br /> m FPC FIRE PROTECTION CONTRACTOR YH YARD HYDRANT P L U M B I N G G E N E RAL N OT ES <br /> � (�I BALL VALVE > : r <br /> J w WATER SERVICE ' <br /> � I �I BUTTERFLY VALVE FPI FINS PER INCH <br /> � � <br /> �a :.,� <br /> �' � � _ <br /> � 1. EXCEPT AS OTHERWISE NOTED, ALL SCHEDULED PLUMBING FIXTURES SHALL BE PROVIDED AND INSTALLED BY �„_,, , ,�,., <br /> � Q THE PLUMBING CONTRACTOR. THE PLUMBING CONTRACTOR SHALL MAKE ALL ROUGH–IN AND FINAL �� ��,������ �.���, ���.�� <br /> U <br /> CONNECTIONS TO ALL PLUMBING EQUIPMENT. <br /> Q 2. REFER TO PLUMBING FIXTURE SCHEDULE FOR PIPWG RUNOUT SIZES TO INDIVIDUAL PLUMBING FIXTURES. <br /> = MECHANICAL SHEET INDEX MECHANICAL CONTACTS MECHANICAL CODE INFORMATION MECHANICAL DESIGN CRITERIA <br /> w 3. DO NOT ROUTE ANY PIPING OVER ELECTRICAL ROOMS, COMPUTER ROOMS, OR ELECTRICAL PANELS. Pro�ect r�a�aye�: <br /> � ALR/CCF <br /> 4. WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE INSTALLED ON CONDITIONED SIDE OF INSULATION. cnecked sy: <br /> � MP-1 MECHANICAL & PLUMBING NOTES & LEGENDS HVAC: RANDALL NELSON P.E. LOCATION: EVEREfT, WASHINGTON. ALR/CCF <br /> � ' MECHANICAL: 2012 WASHINGTON STATE BUILDING CODE 5. UNDERSLAB WATER PIPING SHALL BE TYPE 'K' SOFI' DRAWN WITH NO JOINTS. �rawn by: <br /> i 14$17 WEST 95TH STREET <br /> o MP-2 MECHANICAL & PLUMBING SCHEDULES & NOTES ELEVATION: 43 FT. EA/RC/MK <br /> o LENEXA, KS 66215 6. ALL DOMESTIC WATER PIPING IN CEILING SPACE SHALL BE ROUTED BELOW CEILING INSULATION. <br /> M-1 MECHANICAL FLOOR PLAN–FIRST FLOOR 913-322-5150 <br /> VENTILATION: ZO�Z INTERNATIONAL MECHANICAL CODE �oc�ment date: <br /> j DESIGN CLIMATIC CONDITIONS: COOLING: 86.1/65.6 'F DB / 'F WB <br /> �, 7. PROVIDE PRESSURE REDUCERS AS REQUIRED IN WATER SUPPLY LINES TO KEEP PRESSURE BELOW 70 PSI AT 05/12/2015 <br /> a� M-2 MECHANICAL FLOOR PLAN–SECOND & THIRD FLOOR PLUMBING: WASHINGTON STATE BUILDING CODE (PER 2005 aSHt� FUNDnMENT�..s DEHUMIDIFICATION: 69.5/61.0 'F DB / 'F WB ALL OUTLETS. <br /> � 0.4/99.6% CRITERIA) HEATING: 24.0 'F DB <br /> � � Project No. <br /> � M-3 MECHANICAL FLOOR PLAN–FOURTH FLOOR PLUMBING: RANDALL NELSON P.E. ENERGY_ 2012 WASHINGTON STATE ENERGY CODE 8. PROVIDE PROPERLY SIZED WATER HAMMER ARRESTORS ON QUICK CLOSING VALVES. <br /> / ' AIR COOLED CONDENSER 31000034 <br /> a 14817 WEST 95TH STREET AMBIENT TEMPERATURE: 95�F 9. PROVIDE APPROVED BACKFLOW PREVENTION OR ANTI–SIPHON DEVICES AT ALL FIXTURES THAT COULD <br /> � P-1 PLUMBING WASTE & VENT PIANS–FIRST & SECOND FLOOR LENEXA, KS 66215 <br /> 9�3-322-5�5� CONTAMINATE THE POTABLE WATER SYSTEM. Project Phase <br /> � P-2 PLUMBING WASTE & VENT PIANS–THIRD & FOURTH FLOOR 10. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS. LOCATE TRAP PRIMER VALVES IN ACCESSIBLE LOCATION. DO <br /> > P-3 PLUMBING WATER & GAS PLANS–FIRST & THIRD FLOOR NOT LOCATE TRAP PRIMER VALVES OR PIPING IN AREAS ACCESSIBLE TO THE PUBLIC. CITY PLAN REVIEW <br /> w <br /> I P-4 PLUMBING WASTE & VENT & DOMESTIC WATER RISERS Professional Sea1 <br /> � <br /> a, <br /> a� •L L A . <br /> o(n � ��'�oF wAs���� <br /> Y0 0 <br /> � � `�� 1 l���, �O <br /> �. <br /> � � ��� a� ���. o� � <br /> � � <br />-� � � 1 <br /> � M � <br /> (w!l � O F�'�S, ' `� <br /> � � � `0�, �, 43448 � �� <br /> � / <br /> ! �a <br /> G� <br /> I � ��11� <br /> 0 <br /> � _ , ExPiREs: 09/21/17 � <br /> o � <br /> O v <br /> N p <br /> d <br /> `— Sheet Title <br /> N � <br /> � � <br /> � j . <br /> MECHANICAL AND PWMBING <br /> a / NOTES & LEGEND <br /> N � <br /> � � <br /> t� .� Sheet No. <br /> N O <br /> L <br /> o % MP- 1 <br /> � . <br /> � BRR Original prin[ed on recycled paper <br />