|
42'" MIN �
<br /> 54" MIN �
<br /> 42" MIN 6"-18" 36° MIN 12°
<br /> MIRROR MAX V
<br /> 12" 27" ,� � O
<br /> MAX (- LAV �I `�� �
<br /> � GENERAL NOTES: V a
<br /> 36" MIN GRA BAR i � W�� Z � • DRYING EQUIPMENT, TOWEL OR OTHER DISPENSERS, AND � � '
<br /> 1 .
<br /> � � DISPOSAL FIXTURES SHALL BE MOUNTED SO AS NOT TO �
<br /> Q � o - z � � 30" I �"' ` 16' 18" �., "' EXCEED 40" ABOVE 1}iE FINISHED FLOOR TO ANY RACK, � L
<br /> ��„ "' � � � OPERATING CONTROLS, RECEPTICLES OR DISPENSERS. p
<br /> z ( 60" MIN
<br /> ,� � � � � ,< � � _ • FLUSH CONTROLS SHALL BE ON THE WIDE SIDE OF THE � v�
<br /> � � ¢ .,�,�" � - - L--—- WATER CLOSET. � '�
<br /> � M N °' n- a' • FAUCET CONTROL HANDLES SHALL BE LOCATED NOT �
<br /> L
<br /> � � � FIXTURE CLR FLR SPACE MORE THAN 20" FROM THE FRONT EDGE OF THE LAV. �
<br /> SINK OR COUNTER. HANDLES, PULLS, LATCHES & OTHER �
<br /> 6" RUBBER BASE NOTE: SEE ANSI A117.1-2009 OPERATING DEVICES SHALL HAVE A LEVER OR OTHER � �
<br /> SEC 603.2.3 DOOR SWING, EXCEPTION. SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM
<br /> #2/ SEC. 305.3 30"x48" CLR fLR PRESSURE.
<br /> � _1
<br /> SPACE PROVIDED Q
<br /> • GRAB BARS SHALL BE 1 1/4" MIN & 2" MAX DIA. AND
<br /> TYP ACCESSIBLE RESTRM CLEARANCES & NOTES SHALL HAVE A SPACE OF 1 1/2" MIN BETWEEN THE �
<br /> � NOTE: SEE ANSI A117.1-2009 GRAB BAR AND WALL � W '
<br /> N.T.S.
<br /> \
<br /> 1 2 3 4 5 6 7 � �
<br /> � N
<br /> � �
<br /> O)
<br /> �A - . . . . . . . . . . . _ . . . W �
<br /> — �_-�, o� sti _ w
<br /> �� � � � � CUST (E STAIRS I� - Q Y
<br /> �L-fi- 500 522 � � � � Q o0
<br /> � � � II � �
<br /> ,
<br /> L_J Il
<br /> (E MECH. . �A . 520 � I I � N .
<br /> j ; . / > 500 5 2 3 ' 4 x 0 O I I ��� U N
<br /> (E) WO NS ' � I I �� � O
<br /> 5� � -- � � �---� �_____
<br /> Nol
<br /> �' I � � Mcp
<br /> . . � F= . � _� 519 ; M � � '�`�
<br /> . MENS � . - II � p ..
<br /> 503_ � � � _ (E) 2-HR STAIR � M I I m z
<br /> -1, �E� V-1 ea (E� V-2 t ENCL. W/ 1 1/2HR � � � ' O
<br /> r-r�-� DOORS �� � / � � PRES. OFFICE � � _
<br /> � �� � � � � � 518 a- �
<br /> ; L��- 522 521 =___� - --J
<br /> rr� o -- --�_� 932 S.F.
<br /> �I � (E) 2HR ELEV. ENCL. � 5,�$ �o � 9 OCC
<br /> �I 502 �\ W/ 1 1/2HR DOORS � O C° �� �
<br /> 5'-11" 4'-6' �
<br /> �� �-- -------------- --� I .
<br /> - -
<br /> jg . . _.— . . . . . . . . . . . . . _ . . . . . �_ .. . . . . . -.— ------ .: --- . -- . .-�� . . . . . . .
<br /> , � �
<br /> , Cj
<br /> II 15'-6° _ i� o �� F � � O
<br /> � � � � EST�M I II � ~ n1
<br /> STOR. �� � - I I o0
<br /> . . � 504 �� - . � - 51 I I � Z �
<br /> 0
<br /> . . � 182S.F. �I . , � ( �------
<br /> � I�-- __-- --- _ I �-----� �--- W z
<br /> � � II � O
<br /> IC== � ��---' __ ��__-��� � � � � � I-
<br /> 503 �� �' ���l� '�� � � 5 6 I I `,
<br /> , . �I �'� �� � � � �
<br /> II � ��/ � � � I � ��_ll II � W =
<br /> . . •
<br /> 504 I I n ��,� � (�� � � ,
<br /> _ II � � � � W Q
<br /> O �
<br /> I �
<br /> j � � N �505E �� �I I •DEFERRED$-S BMITTAL � I �
<br /> � II . � , . I � � �
<br /> , . °' �8� s.F. �� � � �--------- ------- ---^ � L �
<br /> ^ 2 OCC � L------------ � � �
<br /> C . . . . . . . . . . . . --------.:-- -� . . . 1- - - - - - � - �
<br /> � - - . . . . . . - - - . . . .
<br /> - - ----- - �
<br /> \ �� �� � - � � OFFICE � � W
<br /> . . �, � I� .I ( I T I A A: . � . 517 �
<br /> . � .� � AR " M XRS � � � 418S.F. �
<br /> I� II � 5 1 3 4 E � _ 4 OCC W
<br /> : : � �
<br /> M OFFICE �� j j � � � � � �
<br /> , . °� �8�F. �� �I I � ��- � ' S15 Z O
<br /> . ^ 2 oCC I� �I I � ) � � �
<br /> � �------------------ ---� � I- ,
<br /> ----------- 505 L1 2 � .
<br /> - -------� - ,
<br /> � /� �� CUBICLE AREA � W N
<br /> � 524
<br /> II � ��
<br /> ; ; I I 506 : ; 3663 S.F.
<br /> � 68 FIXED SEATS � �
<br /> - o
<br /> `; OFFICE �� �
<br /> N
<br /> _� 507 _ �_� ' OFFICE �
<br /> ts1 S.F. ---�I ; 516
<br /> � . ; . . . . . . ; . . . . . _ . OCC I�- . , . . . . . . , . . . . . . . � - �� 376 S.F. �
<br /> �I 4 OCC
<br /> � �
<br /> � � � OFFICE �/ � � � 514
<br /> � � 508 �-�
<br /> - --- --
<br /> 181 S.F. �_
<br /> z occ � � 513
<br /> : : ��-� 50� �i i � :
<br /> �� � � �
<br /> OFFICE
<br /> �� _ � � -� 515
<br /> I� 508 II � ' 0 490CCF Z
<br /> . . II II ,
<br /> . . �------J� •I I , � � �-`, �11 Q
<br /> -`�-��--�� I I 511 � \/� II II \\/� II �
<br /> - 509 �I O
<br /> - - - � - - --.---- - - - - � -� ' �-
<br /> . . . . . .
<br /> E . . . . — —
<br /> � -+� 182 S.F. f�. . . . �C �
<br /> - -
<br /> ------------- - ,
<br /> ii -------------�� i i
<br /> , , 2 occ �� - � �I �� �
<br /> ' � �� � ' jj ' III��� ' I� ��/ II
<br /> � _ /� � 509 5,o i, i i i i ;' " WALL LEGEND �
<br /> i ii ii ii ; O
<br /> � �_ ��: i i ; � -58 � Q 512 EXISTING CONST. TO REMAIN �
<br /> . . ________�
<br /> � �� I f�� I I �/ ___-= o ENCL. W/ 1 1/2HR
<br /> t20'-1" �` �� 17'-31/2" �� 36'-23/4" / ' 4'-6" DOORS _ EXISTING CONST. TO BE REMOVED �
<br /> �1 �____- _��------ -—---------�
<br /> , , OFFICE II OFFICE , CONF. , . W
<br /> • • 510 I I � 511 . 512 COPY FAX NEW CONST _ �
<br /> 375 S.F. I I 369 S.F. 857 S.F. 513 �
<br /> 4 OCC �� 4 OCC 9 OCC J
<br /> I I
<br /> I I NOTE:
<br /> � � � II ' • (E STAIRS PATCH WALLS, CEILING AND FLOOR TO = �
<br /> 514 MATCH ADJACENT SURFACES �
<br /> LL
<br /> F - - - � - - - � - - - � - - - - - - WALL CONSTRUCTION �
<br /> � � � � TYPICAL INTERIOR WALL CONSTRUCTION:
<br /> 5/s" G.W.B. TYPE X JOB: 1627
<br /> R-15 SOUND (OPTIONAL)
<br /> 3-5/8" 26ga METAL STUDS - 16"o/c DWN: ALT
<br /> LEGEND DATE: 9/19/16
<br /> ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE
<br /> � EXHAUST FAN V.T,O. REV. 11/14/16
<br /> � Z 5TH LEVEL FLOOR PLAN EMERGENCY LIGHTING W/ BATTERY BACKUP (PROVIDE 1 FOOT CANDLE MIN. AT 91 3 RE IHITECTD SHEET N0.
<br /> � � WALKING SURFACE)
<br /> � SCALE: 1/4" = 1'-0°
<br /> � ILLUMINATED EXIT SIGN W/ BATTERY BACKUP (90 MINUTE ILLUMINATION PERIOD)
<br /> . YLOR
<br /> FE4FE - 2A 10BC MIN RATED FIRE EXTINGUISHER, IN A 1-HOUR RATED STATE OF WASHINGTON
<br /> SEMI-RECESSED CABINET, MOUNTED 48" A.F.F. & NOT MORE THAN 75'-0" APART ■
<br />
|