Laserfiche WebLink
DEMOLITION PLAN LEGEND <br />EXISTING CONSTRUCTION TO REMAIN <br />�/ p Q B ITEMS FOR DMMITION SHOWN AS DASHED AND/OR BOLD <br />DEMOLITION GENERAL NOTES <br />A NOTE- AL, NFORMATION 54OHN ON THE DRAWINGS RELATIVE TO EKISiING CONDITONONON9 15 <br />GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT THE GUARANTEE OF ACCURACY. <br />THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. <br />B. COMPLY WITH ALL RULES AND REGULATIONS OF THE GOVERNMENTAL AUTHORITIES HAVING <br />JURISDICTION OVER DEMOLITION WORK. <br />C. INCLUDE COMPLETE REMOVAL AND DISPOSAL OF DEMOLISHED ITEMS. SALVAGE ITEMS WHERE <br />APPROPRIATE, COORDINATED PCKUP OR STORAGE WITH OWNER. <br />D. COORDINATE WITH OWNER FOR SHUT-OFF, UPPING, AND CONTINUATION OF UTILITY SERVICE <br />AS REQUIRED, <br />E. PROVIDE DFMOITION TO THE EXTENT REQUIRED TO ACCOMPLISH NEW CONSTRUCTION. REFER <br />TO ARCHITECTURAL (AND CONSULTANT, IF APPLICABLE) DRAWINGS. <br />F. REMOVE THE FOLLOWING WITHIN AREA OF MAJOR WORK, U NO. EXISTING FLOORING, <br />SUSPENDED CEILING SYSTEM, RUBBER BASE, LIGHT FIXTURES, EQUIPMENT (SALVAGE FOR <br />OWNER), AND WALL COVERING. SALVAGE CEILING. TILES 1 LIGHT FIXTURES IF APPROPRIATE <br />FOR FUTURE USE. <br />G. PROTECT STRUCTURAL ELEMENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION <br />W COORDINATE WITH OWNER TO HAVE ALL EQUIPMENT REMOVED FROM DEMOLITION AREAS PRIOR <br />TO CONSTRUCTION START, U N.O. <br />I. REMOVE, REPLACE, AND RELOCATE EXISTING ELECTRICAL, MECHANICAL, AND FIRE <br />PROTECTION EQUIPMENT/DEVICES AS REQUIRED FOR NEW CONSTRUCTION. AT LOCATIONS <br />WHERE ELECTRICAL IS TO BE REMOVED, PULL OUT WIRING BACK TO PANEL REFER TO <br />CONSULTANT DRAWINGS WEN APPLICABLE COORDINATE WITH OWNER FOR STORAGE/DISPOSAL <br />OF EXISTING LIGHT FIXTURES NOT TO BE RELOCATED. <br />J. REMOVE EXISTING ELECTRICAL CONDUIT, WIRE EQUIPMENT, AND DATA CABLING WHERE <br />INDICATED BY DRAWINGS OR MADE NECESSARY BY NEW WORK. <br />K. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS BETWEEN EXISTING CONDITIONS AND NEW <br />CONSTRUCTION PRIOR TO PROCEEDING WITH THE NORK. <br />L. REMOVE EXISTING FINISHES AS REQUIRED FOR NEW BUILD OUT. PREPARE WALLS AS <br />REQUIRED FOR INSTALLATION OF NEW FINISH TREATMENT. SEE ARCHITECTURAL FINISH <br />SCHEDULE. <br />POKER E EQUIPMENT LEGEND <br />NQN 509E (BUT NOT ALL) OUTLETS MAY ALSO BE SHOWN ON INTERIOR ELEVATIONS, <br />ESPECIALLY WHERE CLARIFICATION IS NEEDED FOR ATYPICAL HEIGHTS, CRIENTATION, AND/OR <br />LOCATION OF OUTLETS. CONTRACTOR SHALL BRING ANY CONFLICTS TO ARCHITECV5 <br />ATTENTION FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. <br />NDIE PROVIDE GROUND FAULT INTERRUPTER, WHERE REQUIRED BY CODE. <br />N= NO BACK TO BACK OUTLETS IN PARTITIONS WITH SOUND INSULATION. SEPARATE <br />OUTLETS BY AT LEAST ONE STUD BAY <br />NU F/S) LISTED BELCH ARE TYPICAL FOR AL SYMBOLS <br />MOUNT 0 IB' AFF TO CENTERLINE OF BOX TYPICAL UNLESS NOTED OTHERWISE. <br />.XX - HEIGHT ABOVE FINISH FLOOR (TO CENTERLINE OF BOX) <br />CLG - CEILING MOUNTED <br />PIG - CEILING OUTLET W/ PIGTAIL, DROP TO b1' A F.F., VERIFY HEIGHT 1 <br />LOCATIONS WITH OMER <br />D . DEDICATED OUTLET <br />E . EXISTING <br />EM - OUTLET CONNECTED TO EMERGENCY POWER <br />GFI - GROUND FAULT INTERRUPTER <br />ABV - OUTLET MOUNTED ABOVE COUNTERTCP 1 SPLASH WHERE APPLICABLE <br />0 I10V DUPLEX RECEPTACLE W/ ADDITIONAL INFORMATION. <br />IIOV FOURPLEX RECEPTACLE <br />V NONE/DATA DUAL JACK <br />PB*—RUSH BUTTON- EMERGENCY SHUT OFF SWITCH <br />g SPEC'AL PURPOSE RECEPTACLE REFER TO EQUIPMENT CUT SHEET <br />1 POWER E EQUIPMENT PLAN GEN. NOTES I <br />PLUMBING DESIGN -BUILD NOTES <br />A. ALL PIPING SHALL BE INSTALLED ON WARM SIDE OF INSULATION, TYPICAL. <br />B. ALL WORK TO MEET REQUIREMENTS OF LOCAL CODES AND ORDINANCES. <br />C. DESIGN BY MECHANICAL SUBCONTRACTOR - PREPARE DRAWINGS AND CALCULATIONS FOR <br />PERMIT, TAKE OUT AND PAT FOR ALL PERMITS AND INSPECTIONS, <br />D. REFER TO ALL DRAWINGS FOR FULL SCOPE OF THE JOB. SEE ARCHITECTURAL DRAWINGS FOR <br />CASEWORK, DICTATING HEIGHT, AND LOCATION OF FIXTURES. <br />E. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND MATERIALS SHALL BE NEW, LATEST MODEL <br />AND THE BEST QUALITY. <br />F. INSTALL ALL EQUIPMENT AND MATERIALS IN WORKMANLIKE MANNER, FOLLOWING THE BEST <br />PRACTICES OF THE TRADE. <br />G. MAKE COMPLETE INSTALLATION OF ALL EQUIPMENT FOR FULL FUNCTIONAL OPERATION AND USE. <br />H. COORDINATE ALL MECHANICAL WORK WITH TWAT OF OTHER TRADES AND THE GENERAL <br />CONTRACTOR. <br />I. PROVIDE BACKFLOW PREVENTERS AT ALL PLUMBING FIXTURES AS NEEDED TO MEET CODE <br />M. REMOVE EXISTING FLOOR FINISHES AND BASE AS REQUIRED FOR THE INSTALLATION OF NEW A SIG w NOT s <br />�> DEMOLITION KEY NOTES <br />I REMOVE DOOR, SALVAGE FOR RELOCATION, AT CONTRACTOR'S OPTION, OR <br />CONTACT OWNER REGARDING DISPOSAL, <br />2 REMOVE EXISTING WALL, PATCH AND REPAIR ADJACENT. SURFACES, <br />3. REMOVE EXISTING EQUIPMENT, <br />FLOOR PLAN GENERAL NOTES <br />OR OTHER PRESCRIBED MATERIALS <br />FINISHED WALL SURFACE TO (MATCH <br />SURFACES BEFORE APPLYING FINISH <br />ELE <br />A. <br />TRI L DESIGN -BUILD D <br />ELECTRICAL WORK SMALL BE DESIGN -BUILD. PLAN SHOWS OWNER'S OUTLETS, PHONE, AND DATA <br />NEEDS, AND 15 DIAGRAMMATIC, EXCEPT THOSE LOCATIONS SPECIFICALLY DIMENSIONED ON PLAN. <br />CONTRACTOR SHALL OBTAIN AND PAT FOR PERMITS REQUIRED FOP. THE WORK IN THIS <br />CONTRACT. <br />B. <br />ALL WORK SMALL CONFORM TO APPLICABLE ELECTRICAL CODE, <br />C. <br />UNLESS OTHERWISE NOTED, ALL MATERIALS SMALL BE NEW AND OF GOOD QUALITY. <br />D. <br />NO OTHER DEVICE SHALL BE CONNECTED TO DEDICATED RECEPTACLE CIRCUITS. <br />E. <br />CONTRACTOR SMALL VERIFY ALL CONDITIONS ON SITE, AND VERIFY WITH OWNER POWER <br />REQUIREMENTS OF OWNER -FURNISHED EQUIPMENT <br />F. <br />IDENTIFY CIRCUITS, CIRCUIT NUMBERS, AND AREA OF EQUIPMENT SERVED. PROVIDE PLAN OF <br />CIRCUITING AT COMPLETION OF JOB FOR OWNER/BUILDING OWNER'S USE, <br />G. <br />INSTALLATION METHODS SMALL COMPLY WITH THE BEST APPROVED METHODS OF DESIGN-BU)LD <br />ND/OR DEFECTS IN <br />WORK INCLUDES VERIFICATION OF EXISTING CAPACITY, AND SHALL ACCOMMODATE ALL NEW <br />JOINT COMPOUND, <br />LOADS, INCLUDING MECHANICAL IF REQUIRED. <br />ROVIDE A UNIFORM <br />H. <br />PROVIDE GFI OUTLETS AS REQUIRED AT WET LOCATIONS. <br />MOON ALL <br />1. <br />PROVIDE ELECTRICAL CONNECTION TO ALL SECURITY PANELS, PLUMBING FIXTURES, MECHANICAL <br />FANS AND UNITS, ETC. AS REQUIRED FOR COMPLETE INSTALLATION. <br />J <br />PROVIDE CONDUIT AS REQUIRED BY LOCAL JURISDICTION. <br />B. REMOVE ALL EXCESS BUILD-UP OF EXISTING AND/OR MEN WALL AND PAINT MATERIALS FROM K. MAKE MODIFICATIONS TO EXISTING FIRE ALARM SYSTEM AS REQUIRED BY NEW CONSTRUCTION. <br />ALL NEW AND EXISTING WALL SURFACES INCLUDING BUT NOT EXCLUSIVE OF: PLASTER, PATCHING <br />COMPOUND, PUTTY, MASTIC, ETC. CLEAN AND FINISH SAND SMOOTH WALL SURFACE READY FOR <br />THE APPLICATION OF FINISH. <br />C. PROVIDE FOR A UNIFORM FINISHED WALL SURFACE ALL THE WAY DOWN TO TOE FINISHED FLOCK <br />TO ALLOW FOR THE PROPER INSTALLATION OF THE SPECIFIED WALL BASE. THAT INCLUDES <br />TAPING AND FINISHING ALL VERTICAL JOINTS AND BEADS DOWN TO THE FINISHED FLOOR ALONG <br />WITH FILLING ALL SCREW HOES AND FILLING ALL VOIDS. <br />D. LEV& THE FLOOR SURFACE/SUBSTRATE WITH A LATEX UNDERLAYMENT SMOOTH AND FREE FROM <br />CRACKS, MOLES, RIDGES, COATINGS PREVENTING ADHESIVE BOND AND OTHER DEFECTS <br />IMPAIRING PERFORMANCE OR APPEARANCE. MAXIMUM ALLOWABLE SLOPE IS 114' IN 10'-0'. <br />FINISH SAND SMOOTH TO PROVIDE AN ADEQUATE SUBSTRATE FOR THE INSTALLATION OF THE <br />SCHEDULED FLOORING MATERIAL, <br />E. PROVIDE AS BUILT DRAWNGS. FOR OWNER OF ANY ELECTRICAL, PLUMBING, FIRE SUPPRESSION, <br />OR HVAC MODIFICATIONS. <br />FLOOR PLAN LEGEND <br />EXISTING WALL <br />NEW FUMED WALL OR PARTITION, SEE DETAIL II I <br />-- 50JND INSULATION IN PARTITION AND 4'-0' EACH SIDE ON <br />CEILING <br />ROOM ROOM NAME 4 <br />® ROOM NUMBER <br />(FIRST NUMBER INDICATES FLOOR NUMBER) <br />114VAC GENERAL NOTES I <br />HVAC DESIGN -BUILD NOTES. <br />A. ALL DUCTWORK 51IALL BE INSTALLED ON WARM SIDE OF INSULATION, TYPICAL. <br />B. ALL WORK TO MEET REQUIREMENTS OF LOCAL CODES AND ORDNANCES. <br />C. DESIGN BY MECHANICAL SUBCONTRACTOR - PREPARE DRAWINGS AND CALCULATIONS <br />FOR PERMIT, TAKE OUT AND PAT FOR ALL PERMITS AND INSPECTIONS. <br />0. REFER TO ALL DRAWINGS FOR FULL SCOPE OF THE JOB. SEE ARCHITECTURAL <br />DRAWINGS FOR CEILINGS, DICTATING HEIGHT, AND LOCATION OF LIGHT FIXTURES. <br />E. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND MATERIALS SHALL BE NEW, LATEST <br />MODEL AND THE BEST QUALITY. <br />F. INSTALL ALL EQUIPMENT AND MATERIALS IN WORKMANLIKE MANNER, FOLLOWING THE <br />BEST PRACTICES OF THE TRADE <br />4. MAKE COMPLETE INSTALLATION OF ALL EQUIPMENT FOR FULLY FUNCTIONAL OPERATION <br />AND USE. <br />H. COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES AND THE GENERAL <br />CONTRACTOR. <br />I. PROVIDE ADEQUATE COOLING FOR NEW EQUIPMENT, AND FUTURE PROPOSED EQUIPMENT. <br />I TYP. @ NEW <br />A5,1 WALL <br />51-511 <br />-011 31-011 <br />boiler <br />(V <br />TO <br />CN <br />sterilizer <br />O_ (existing <br />to remain) <br />311 JOG <br />NEW WALL <br />OEQUIPMENT PLAN NO IN <br />SCALE- 1/4' . V-C' <br />u <br />Z <br />=(As_� <br />Q` <br />a/4-71 <br />u wj <br />�3 <br />SEAL <br />nR <br />DWASHWON <br />Z <br />v ,u <br />Ju <br />1-. W U <br />Ln <br />a <br />— � r <br />mLU WN <br />i E am <br />00wa <br />w 3 <br />._ <br />N cu <br />OLnrmnw <br />ABA IIIIMBEA: MIN <br />WANK vw,K <br />011Q <br />DATC Eml It RCRM <br />IILNFIRIR: <br />SHEET TITLE: <br />PLANS & NOTES <br />PERMIT/BID SET <br />SHEET NUMBER. <br />A2.0 <br />