My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2916 STATE ST BSNW LLC 2019-04-17
>
Address Records
>
STATE ST
>
2916
>
BSNW LLC
>
2916 STATE ST BSNW LLC 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 9:52:55 AM
Creation date
4/17/2019 9:52:42 AM
Metadata
Fields
Template:
Address Document
Street Name
STATE ST
Street Number
2916
Tenant Name
BSNW LLC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 6 <br /> 3802.1 Location. Marijuana processing shall be located in a building <br /> complying with the International Building Code and this code. The mar- <br /> ijuana extraction process shall be located in a room dedicated to the <br /> extraction process. The extraction room shall not be used for any oth- <br /> er purpose including storage. <br /> 3802.2 Staffing. The extraction process shall be continuously staffed <br /> by personnel trained in the extraction process, the transfer of LP-gas <br /> where applicable, and all emergency procedures. All staff training re- <br /> cords shall be maintained on-site by the owner and made available upon <br /> request from the fire code official. <br /> 3802.3 Systems, equipment and processes. Systems, equipment, and pro- <br /> cesses shall be in accordance with Sections 3802,3. 1 through <br /> 3802.3.3.7. . <br /> 3802.3.1 Application. Systems, equipment and processes shall include, <br /> but are ' not limited to, vessels, chambers, containers, cylinders, <br /> tanks, piping, tubing, valves, fittings, and pumps-. <br /> 3802.3.2 General requirements. In additie-• to the requirements in Sec- <br /> tion 3802, systems, equipment and processes shall also comply with . <br /> Section 5003.2, other applicable. provisions of this code, the Interna- <br /> tional Building Code, and the International Mechanical Code. <br /> 3802.3.3 Additional requirements for marijuana extraction. In addition <br /> to the requirements of Section 3802.3, marijuana extraction systems, <br /> . equipment and process shall comply with this section. <br /> 3802.3.3.1. General requirements. The requirements set forth in Section <br /> 5003.2 shall apply to vessels, chambers, containers, cylinders, tanks, <br /> piping, tubing, valves, fittings, .and pumps used in the extraction <br /> process. The use of ovens in post-process purification or winteriza- <br /> tion shall comply with Section 3802.3.3.7. <br /> 3802.3.3.2 Systems and equipment. Systems or equipment used for the <br /> extraction of marijuana/cannabis oils from plant material shall be <br /> -. listed for the specific use. If the system used for extraction of mar- <br /> - ijuana/cannabis oils and products from plant material is not listed, <br /> then the system shall have a designer of record. If the designer :of <br /> record is not a licensed Washington professional' engineer, then the • <br /> system shall -be peer reviewed by a licensed Washington professional <br /> engineer. In reviewing the system, the licensed professional engineer <br /> shall review and consider any information provided by the system's de- <br /> signer or manufacturer. For systems and equipment not listed for the <br /> specific use, a technical report documenting the design or peer review <br /> as outlined in Section 3802.3.3.4.2 shall be prepared and submitted to <br /> the fire code official for review and approval for systems and equip- <br /> ment used for the extraction of marijuana/cannabis oils and products <br /> from plant material. The firm or individual performing the engineering <br /> analysisfor the, technical report shall beapproved by the fire code <br /> official prior to performing the analysis. <br /> 3802.3.3.3 Change of extraction medium. Where the medium of extraction <br /> or solvent is changed from the material indicated in the technical re- <br /> port or as required by the manufacturer, the technical report shall be <br /> revised at the cost of the facility owner, submitted for review and <br /> approval by the fire code official prior to the use of the equipment <br /> with the new medium or solvent. If the original engineer of record is <br /> OTS-7182.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.