My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2916 STATE ST BSNW LLC 2019-04-17
>
Address Records
>
STATE ST
>
2916
>
BSNW LLC
>
2916 STATE ST BSNW LLC 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 9:52:55 AM
Creation date
4/17/2019 9:52:42 AM
Metadata
Fields
Template:
Address Document
Street Name
STATE ST
Street Number
2916
Tenant Name
BSNW LLC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • <br /> • <br /> primary step or component. A piping and instrumentation diagram (PID <br /> or PI&D) may be provided but is not required. <br /> 9. Analysis of the vessel (s) if pressurized beyond standard at- <br /> mospheric pressure, Analysis shall include purchased and fabricated <br /> components. <br /> 10... Structural analysis for the frame system supporting the <br /> equipment. <br /> 11. Process safety analysis of the extraction system, from the <br /> introduction of raw product to the end of the extraction process. <br /> • 12. Comprehensive process hazard analysis considering failure <br /> modes and points of failure throughout the process. This portion of <br /> the review should include review of emergency procedure information <br /> • provided by the manufacturer of the equipment or process and not that <br /> of the facility, building or room. <br /> 13. Review Of the assembly instructions, operational and mainte- <br /> ' nance manuals provided by the manufacturer. <br /> 14. Report shall include findings and observations of the analy- <br /> sis. <br /> 15. List of references used in the analysis. <br /> 3802.3.3.5 Building analysis. If the technical report, or manufactur- <br /> ers literature indicate specific requirements for the location, room, <br /> space or building, where the extraction process is to occur, the engi- <br /> neer of record, as approved in 3802.3.3.4.1 shall review the construc- <br /> tion documents of such location, room, space or building and provide a <br /> report of their findings and observations to_ the fire code official. <br /> Analysis shall include; <br /> 1. Process safety analysis of the entire process from raw materi- <br /> al to finished product. <br /> 2. Comprehensive process hazard analysis considering failure <br /> modes and points throughout the process. Should include revzew. . of <br /> emergency procedures as related to the equipmentor process, and the <br /> facility. <br /> 3802.3.3.6 Site inspection. Prior to operation of the extraction <br /> equipment, if required by the fire code official, the engineer of re- <br /> cord, as approved in 3802.3.3.4 .1 shall inspect the site of the ex- <br /> • <br /> traction process once equipment has been installed for compliance with <br /> the technical report and the building analysis. The engineer of record <br /> shall provide a report of findings and observations of the site in- <br /> spection to the fire code official prior to the approval of the ex- <br /> traction process. The field inspection report authored by engineer of <br /> record shall include the serial number of the equipment used in the <br /> process and shall confirm the equipment installed is the same model <br /> and type of equipment identified in the technical report. <br /> 3802.3.3.7 Post-process purification and winterization. Post-process- <br /> ing and winterization involving the heating or pressurizing of the <br /> miscella to other than normal pressure or temperature shall be ap- <br /> proved and performed in an appliance listed for such use. Domestic or <br /> commercial cooking appliances shall not be used. The use of industrial <br /> ovens shall comply with Chapter 30. <br /> EXCEPTION: An automatic fire extinguishing system shall not be required for batch-type Class A ovens having less than 3.0 cubic feet of work space. <br /> 3802.4 Construction requirements. <br /> 3802.4.1 Location. Marijuana extraction shall not be located in any <br /> building containing a Group A, E, I or R occupancy. <br /> OTS-7182.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.