Laserfiche WebLink
f <br /> Esse=ntial Process Engineering <br /> CLOSED LOOP EXTRACTOR SECURING: <br /> The Closed-Loop Extractor system must include a system for securing the assembled material vessel to the processor <br /> room wall to maintain equipment stability during use and storage. Figure 12.1 shows the installation of the wall <br /> mounting system. A system of equal capability may be used. <br /> Use%" Diameter <br /> Screw to wall stud <br /> Wall mount bracket <br /> (Figure 12.3) <br /> Vibration-Damping <br /> Clamp (Figure 12.2) <br /> r <br /> v .. ,71) <br /> • r <br /> f ,a <br /> Figure 12.1—Wall Mounting System (Or Equal) <br /> 5/3/2016 Project: 1604141_BrianKnopf Extractor Page 26 of 34 <br /> EPE Doc. 160414ER Confidential- Proprietary Document Butane USE ONLY <br />