My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3103 TULALIP AVE 2019-04-17
>
Address Records
>
TULALIP AVE
>
3103
>
3103 TULALIP AVE 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 1:22:58 PM
Creation date
4/17/2019 1:22:46 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3103
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Responses to Corrections for 3103 Tulalip Ave, Everett, WA 98201 <br /> Plan Check Number: CW1703-002 <br /> Consulting Structural Engineering Services,Inc. <br /> 17. Header size, species, and grade in all bearing walls in the basement are illustrated on page <br /> S100 in the Structural Plans on the updated plan set provided with this letter. <br /> 18. Footings under bearing walls in basement at new stair opening or beam size are provided <br /> on A102 in Floor Plans, in figure 1 on A300 in Sections, and on S100 in Structural Plans on the <br /> updated plan set provided with this letter. <br /> 19. Detail(s) for guard construction per section R312IRC including all components of guard <br /> system are provided on A102 in Floor Plans, in figure 1 on A300 in Sections, and on S100 in <br /> Structural Plans on the updated plan set provided with this letter. <br /> 20. See whole-house Ventilation System Summary on page A000 for whole-house ventilation <br /> system per Section M1507. <br /> 21. Landing at all entrance/exits including showing size and location are added to page A102 in <br /> Floor Plans on the updated plan set provided with this letter. <br /> 22. See Ventilation System Summary on page A000 for source specific exhaust fan in the <br /> bathroom on the lower floor. <br /> 23. See pages R1 and R2 in the calculations package for section BB on A300, collar ties 2x8 <br /> resolving tension loads, ensuring the members and connections are sized appropriately for the <br /> tension loading provided. <br /> 24. On sheet 2/A300 and 4/S200, it appears that CMU walls are present from site photos along <br /> the west elevation. However, existing 2x4 exterior studs are being called out. Please Clarify. <br /> Also, CMU wall construction appears to be new, please provide calculations addressing the <br /> design for the wall for gravity and out-of-plane lateral forces. <br /> The existing west wall is concrete on the bottom and a CMU on top. A new 2x6 wood framed <br /> pony wall is to be added on top of the existing CMU wall, to raise the floor level. In order to <br /> accommodate the additional out-of-plane loads from new pony wall, the new 2x6 furring wall is <br /> detailed with a brace connecting to the bottom of the new pony wall, such that any new forces <br /> from the new wood pony wall are resisted by the wood furring wall, instead of the existing <br /> CMU wall. See detail 2/S101 and calculation pages L4-L5. The CMU walls are entirely existing. <br /> 25. On 4/S200, CMU walls appear to be new and installed as part of the bearing wall system of <br /> the structure. Please provide details and calculations addressing out-of-plane wall anchorage <br /> connection to brace the wall per ASCE 7-10 Sec 12.11.2.1. <br /> As already shown on the plans, no new CMU walls are included in this project. <br /> 26. The LVL ridge beam size shown on 2/S100 does not match the size shown on the permit <br /> calculations (R1 beam). Please revise and clarify on drawings on the proposed size shown on <br /> permit calculations are actually beams "sistered" together. <br />
The URL can be used to link to this page
Your browser does not support the video tag.