Laserfiche WebLink
GENERAL YES <br /> Bathroom doors are easily and quickly openable from the outside when locked 0 <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. [ 1❑ <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(R314). 1❑ <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all ®�® <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. ❑ -0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 131---- <br /> Pocket <br /> Pocket doors shall have graspable hardware available when in the closed or open position. Q%/ - 0 0 <br /> R311.8 Ramps .{�/// YES NO <br /> Inside Ramp N/A L7 0 . 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. 0 0 <br /> Outside"Ramp N/A 0 YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 13/ 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes ®� ❑ <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. Itr ❑ <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards 131--13 <br /> Handrail both sides <br /> -- -- Less than 4" 34"-38" <br /> 1 <br /> Guard <br /> 36" <br /> min <br /> 3'x 3'min <br /> landing <br /> 3'x 3'min „'----.- <br /> landing ..���""'�— --•-�, <br /> 3' — One unit vertical in twelve units horizontal } 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 1i! <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 1.7 ❑ <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry ❑ <br /> without use of key,tool or sped nowledge. Required exit door shall have no additional locking devices. <br /> R311.7 Stairways N/A YES NO <br /> R311.7.4.1 Riser Height:Max riser height shall be 73/4 inches(8 inches in structures built prior to July 1,2004) . 0 0 <br /> R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple ❑ <br /> risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 <br /> Effective:2013 July 01 16 I <br /> Updated:2013 June <br />