Laserfiche WebLink
OTTO ROSENAU & ASSOCIATES, INC. <br /> Geotechnical Engineering,Construction Inspection&Materials Testing <br /> CONCRETE REPORT <br /> ob Number: 16-0175 Report Number: RC367456 Permit Number: See Below <br /> Project: Riverfront Simpson Client: Polygon Northwest <br /> Address: 4312 30th Drive SE, Everett Address: 11624 SE 5th Street,Bellevue <br /> Inspector(s): Brian Robertson,Jonathan Andrews Date: 4/9/2018 <br /> Description/Location: Inspected reinforcing steel and concrete placement for footings and foundation walls for Lots 154 and 157. <br /> Electrical UFER ground rods and and hoidowns are in place The inspected work was fouind to be done as per <br /> approved project documents. <br /> Lot 154-4311 30th Drive SE-C1801-010 <br /> Lot 157-4317 30th Drive SE-C1801-013 <br /> Rebar Verified: Yes 4/9/2018 Brian Robertson(Grade 60) Mfg: Nucor <br /> Placement Data ` Design R.: Actual ❑ Batch Weights/Cubic Yard <br /> Supplier: Miles Cement(lbs/type): 410# Type: I/II <br /> Mix Number: 18350FP Fine Agg.(lbs): 1570# <br /> Slump Spec: 4"t1" 200 lbs.3/8" Slaglbs): <br /> Coarse Agg.(lbs/size): <br /> W/C Ratio Spec: 0.532 Coarse Agg.(lbs/size): 1650 lbs.7/8" <br /> Air Spec: n/a Coarse Agg.(lbs/size): <br /> Total Yards: 49.5 Fly Ash(lbs): 60# <br /> Placed Via: Boom Pump Water(lbs or gal): 30gal <br /> Consolidated: Yes Admixtures(specify): <br /> Required Strength: 3000 psi @ 28 days <br /> Sampling and Testing Data Time Cubic Water Slump Air% Conc.Temp Ambient Truck Ticket <br /> ASTM C 172,C 31 Made Yards Added C-143 C 231 C 1064 Temp No No.- <br /> 1 ast <br /> o.- <br /> ast Samples: 1-4 12:10 pm 10.00 0 gal. 3" n/a 61°F 59°F C055 205111 <br /> Weather. Clear Slump Range: 4"+/-1" Air%Range: n/a <br /> Date Samples Picked Up: 4/10/2018 Initial Curing Method: ASTM C31,Exclude C31-12.1.5 Initial Curing Temp: ASTM C31 Exclude c31-1a12 <br /> Comments <br /> REINFORCING/PLACEMENT: Conforms:v❑ Does Not Conform:❑ <br /> COMPRESSIVE TEST RESULTS <br /> Specimen Test Field Age Size Area Weight Max Load Strength Fracture Type <br /> Number Date Cure (Days) (in.) (Sq.ln.) (Lbs.) (Lbs.) (psi) (other than cone) <br /> 1 4/16/18 7 4 x 8 12.56 8.7 43,270 3450 3 <br /> *=Discarded <br /> Tested in general accordance to: ASTMC39 j ASTMC617❑ ASTMC1231 ❑ <br /> Copies to: <br /> Client [1Engineer 0 Batch Plant <br /> CI Owner Q Contractor CI Others Technical Responsibility: } <br /> ❑Architect ❑ Building Dept ai{er Hansen,Project Manager <br /> is <br /> s report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates,Inc. Reproduction of this <br /> Abort except in full,without written permission from our firm is strictly prohibited. <br /> 6747 M.L.King Way S.,Seattle,Washington 98118-Phone(206)725-4600 or 1-888-OTTO-4-US-Fax(206)723-2221 <br /> Form No.:ADMIN-62-04(Rev 09/06) Page 1 of 1 <br />