X44 9 5b ' <br /> GEODESIGN FIELD REPORT <br /> -1-ef tr"- <br /> Project Name: Everett River Front-Simpson Report 027 <br /> GeoDesign#: Polygon-127-03 Date 02/03/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW 1505-005 <br /> ' °-ca% "'�'.'`y'"•„m._ 1•.".; .zc..c. ..,.,'ate".i.,.....t au,i.k. :""a.M.L .xutt as.s,....,..,u....&,.. _,r..<,w..,. ,,,.,77N..,+..�.A,r,. a:+.'>'"."v t°za "t wss.,. :. ,r,».x:ec.,,:.;.:�Sv. '=-,- „w. .:'v.`...:r 4 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather Light Snow, 30's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 0830/0900 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> m Site Plan(s) m Density Test Summary Signature: sq-,;-- <br /> Attachments: 0 Installation Records E] Other <br /> Reviewed By: 7e,„ <br /> PURPOSE of VISIT: GeoDesign representative, Ben Weinberg,was on-site part time at the request of John Feltner with <br /> Polygon to observe the foundation subgrade for Lots 142 and 143. <br /> SUMMARY of OBSERVATIONS: <br /> Lot 142: <br /> Previously, GeoDesign observed the over-excavation of an area in the northwest corner down to firm and unyielding <br /> material. Today, GeoDesign noted that the foundation excavation subcontractor had placed a layer of non-woven geotextile <br /> material and backfilled the area with a 2-4 inch recycled concrete material which was compacted into a firm and unyielding <br /> mass. Relative compaction of the exposed subgrade material for the rest of the footing area was tested using a Troxler <br /> Moisture-Density gauge; in-place density tests indicated that the exposed subgrade material had been compacted to <br /> greater than 95%of its maximum dry density as determined by a Modified Proctor analysis. <br /> It is the opinion of GeoDesign that the footing subgrade area observed today is currently suitable for support of the intended <br /> load. GeoDesign recommends that any surficially loose and saturated material which may build up be removed from the <br /> base of the footing area prior to the placement of concrete. <br /> Lot 143: <br /> Previously, GeoDesign observed the over-excavation of an area on the west 1/3 of Lot 143 down to firm and unyielding <br /> material. Today, GeoDesign noted that the foundation excavation subcontractor had placed a layer of non-woven geotextile <br /> material and backfilled the area with a 2-4 inch recycled concrete material which was compacted into a firm and unyielding <br /> mass. Relative compaction of the exposed subgrade material for the rest of the footing area was tested using a Troxler <br /> Moisture-Density gauge; in-place density tests indicated that the exposed subgrade material had been compacted to <br /> greater than 95%of its maximum dry density as determined by a Modified Proctor analysis. <br /> It is the opinion of GeoDesign that the footing subgrade area observed today is currently suitable for support of the intended <br /> load. GeoDesign recommends that any surficially loose and saturated material which may build up be removed from the <br /> base of the footing area prior to the placement of concrete. <br /> A summary of our observations and density tests taken today can be found in the attached Figure 1 and Nuclear Density <br /> Gauge Data. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project Irrespective of the presence of our representative.Ourwork does not includesupervision orr direction of the contracwr;.the contractor's employees <br /> or agents.Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations;testing,and preliminary recommendations.The report canopy be considered <br /> final upon review of the GeoDesign project manager,as indicated by Initials in the"Reviewed By section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue 1 Tacoma,WA 98402 1 253.203.0095 / <br />
The URL can be used to link to this page
Your browser does not support the video tag.