Laserfiche WebLink
� -- _-- - - - - — — _ ._ _ _ __ . <br /> AAccess for Water heater ' <br /> � <br /> � <br /> 3 <br />� Y <br /> �lOTES/ � EGEf� Ds <br /> 1 1 ' 10" x 4' Tempered Glass vinyl low E <br /> C � I � 1 ' 10" x 3' vinyl low E <br />� HEADERS TO COVERED WITH R10 RIGID FOAM <br /> Detail all openings as Moisture Control Layer I <br /> Tape seams in foam as Moisture Cantrol Layer 2x4 16"oc Stud Wall r'') <br /> HOUSEWRAP SHINGLE LAP AND TAPE SEAMS ( � � /I 3 �' X G' v i n y I I O W E <br /> 4 <br /> RIG�D FOAM INSULATION R10 <br /> R13 BATT INSULATION Ri3 BATi INSULATION • <br /> 1 X FURRING 16"OC USE 3 1/2" EXTERIOR GRADE SCREWS 3/4" Tt t t 3/4" Tt 11 �� X 5� Te m p e re d G I a s s v i n y I I�W E <br /> SIDING <br /> - - - - - - - - - - - - - - - - - - - - A B <br /> FLASH�NG WITH 1/4" DRIP EDGE EXterlOr poors <br /> CONC. SLAB I <br /> BY OTHER I <br />� PROTECTION FOR RIGID FOAM APPIJED ABOVE GRADE • � � d a, d � I 3/H��_ � � W K i t c h e r n S i n.k Fa u c e t ra t e d � � .7 5 G P M 0 r I e Jc S <br /> � Q. . . A..�. . . ... � <br /> °. � � � ' ' o�h SCALE <br /> � . �.,.;.; <br /> � ,•,�' ��,�:��� �°. ( Showerhead rated 1 .75GPM or Less <br /> . . � <br /> RIGID FOAM INSULATION MIN 24" DEEP FROM SLAB TOP • <br /> a � . . d � a ,a . I � Lavatory Sink rated 1 GPM or less ' <br /> . � � <br /> � , a . <br /> � C ���a � . a� � �a . a 1 w <br /> a:.a <br /> a: a I Ductless split system heat pump OUTSIDE UNIT <br /> 3�4„— � , � - c I C 1 <br /> ° Q SCALE ° � v ° C 1 Vaulted Ceiling R26 Batt Vented 1 60C <br /> I <br /> Retrofit of current exterior wall & slab Current exterior wall & slab � C � R49 BlOwrl Baff led verlted <br />� B � A <br /> � C 3 Vaulted Ceiling R30 Batt Vented 240C <br /> TYPICAL EXTERIOR WALL 8c SLAB SECTION � � <br /> Retrofit of current exterior wall & slab <br /> � �`�'�-7r_c ' i� i �;l�.Sji�t� ��I � <br /> to comply with 2015 WSEC .�d� �S � <br /> Attic Venting <br /> A <br />�' Attic Area Cincluding eave & sof f it) <br /> P �AN W1 see UA a ternative worl� sheet and notes ) SEE P �AN �OR DIME �1510 �15 _ . <br /> � , , <br /> - 28 x 24 <br /> _ .���=�sq,f't, <br /> --- ROOF SHEATHING PER SHEET S1 ReC�UIY,e� Attic Ventilation Area <br /> 2X10" PER SHEEf S1 c r <br /> R26 BATT INSUlAT10N PER R402.1.4 Total UA altemative — l��� S q� I �� � ��� <br /> R30 BATf �NSUTAT�ON <br /> _ �,24 sq,f t, . <br /> — MAINTAIN 1" NR GAP ABOVE INSULATION . <br /> _ -� �I�� sq,in, <br /> SOFlT VENTING TO BE EQUAL TO OR MORE THAN 161 SQ.IN � <br /> BLOCKING TO HAVE LEAST 5 SQIN PER 16 OC SECTION S O� �1- a r e a Q S r i d g e v e n t i l a t i o n <br /> SOFlT VENTING TO BE EQUAL TO OR MORE THAN 161 SQ.IN <br /> _ :��� sq,in, <br /> 50% o F area as sof�it ventilation <br /> 5.5"X13.5" BEAM PER SHEET Si — t��_�� S q��n� <br /> SECTION AA RENOVATION TO ROOF AND RAFTERS 1, Sof�it to get venting with screen equaling above �ree areas <br /> Retrofit of current Roof and Rafters <br /> BLOCKING TO HAVE LEAST 5 SQIN PER 16 OC SECTION <br /> Details Shown in S1 and in appendix SDA all hardware and hangers omitted for ciarity �, Each gable end t0 recieve louvred vent equaling abOV2 free areas <br /> 3, 1" Free area loetween insultion and roo� <br /> -- RAFfER 2X6 WITH 2X4 FURRING 160C TO BE REMOVED <br /> ROSE �IBERG 2410 Maple 98201 � <br /> P �AN and DETA �S for Retrofit to 201 5 WSEC <br /> � EXISTING ROOF AND RAFTERS <br /> Rev02 � 1 1 8e3 Page w 1 � <br /> , <br />