—MSTALL NEW GWB �
<br /> CEWNG�+9'-0"A.F.F.
<br /> SEE DETAIL BE�OW LIGHTWG FIXTURE SCHEDULE: �;�,��� � �� � ,
<br /> �I�i"�
<br /> " _. . . . _.. - . _ _ �
<br /> . _ . �. . _ . ,
<br /> ' '' . . ' ` ��� �� � I' ;-� '' �^ = A 8 FT LINEAR PENDANT LED FIXTURES (8 3/4" X 1 3/4" X 8'-0�� LONG)
<br /> � . • �:. .'• , 7 �`� �� J �. � -c " — -- "LtTHONIA GRAD LINEAR, SPEC
<br /> '�. '•'� � ' =•"' �'� ���� it;z. � �l � _ GRDLLPI6FTMSL880CRI30KID10 OLMF80/20MINI1ZT720SCTF736AC210". <32 WATT>
<br />� � ;'?'RFpTP� P�T NivJPi � S;AF� !'GFF!CG� ���'.1 � • I• •�o .. �
<br /> . oa c �:'c'�" �5 . ' (;�'1 ��x .i��_'�� _
<br /> . . • �c••.'• lJ i � ' _
<br /> . . . . . •� • �?_s ''%I• � • _ O NEW 4" SQUARE RECESSED LED OOWNLIGMT WITH DIMMER:
<br /> � `��•• '..�' ' '' I �I '�� 06� ' ' � ' _ � "LITHON{A LDN4SQ-35/15-LS4AR-TRW-LD-MVOLT-EZ1 WITH DIMMER SWITCHES",
<br /> " ' '� `• •�,!; - ��'-�' ' !�' � . � .• ���� � FINISH: WHITE FLANGE WITH MATTE DIFFUSE FINISH. G20.2 WAT17
<br /> . '.�• ' ','f.<. .�I II � \'t�• oa � •''I�.• � _
<br /> :�� _
<br /> F.E.c. = NEW UNDER CABINET LED LIGHTS: "TECH UGHTING UNILUME LED SLIMLINE
<br /> = 700-UCF-XX-8-2-W-LED", FINISH: WHITE. LENGTHS WILL VARY (7", 13", 19", 30"},
<br /> � SEE CABINET ELEVAl10NS. BUTT FIXTURES TOGETHER AND MOUNT DIRECTLY BEHIND
<br /> �CE�LING OPEN TO � = G VALENCE WITH DIFFUSER FACING WALL ElEC1R�CIAN TO PROVIDE CONDUIT TO EACH
<br /> srnucivae aeove = LIGHT BANK. LOW PROFILE WITH ROCKER SWITCH.
<br /> , � EXISTING 6X6 CQLUMN � _ � LED EXIT L1GHTiNG: "LITHONIA LtGHTiNG. GREEN EDGE-l.iT LED OVAL EXIT SIGN, SOlO
<br /> �`� H W 1 GMR SD", CEILING MOUNTED. ADD PEN�ANT, 36" "ELASOLOPM36"
<br /> J -
<br /> — LJ PAELMLTWLPQ V5LTP5D�GHTS WITH BATTERY BACKUP: "QUANTUM THERMOPLASTIC EM
<br /> J
<br /> �� � A - EXHAUST FAN (MECH RM/RESTROOM): "NUTONE QTXEN SERIES EXHAUST FAN QTXEN
<br /> A = K� 150" 450 CFM>
<br /> _ RESTROOM VANITY LEO WAL� UGHTIN6: "TECHUGHTIN6 ALDEN BATH UGHT,
<br /> - � 7008CALD-Y-S-LED830", ACRYI.IC-SAl1N NICKEL" <20 WATT> CLIENT/PROJECT:
<br /> . � - NO WORK THIS AREA M
<br /> PNW Physical Therapy, LLC
<br /> TREATh,1cNT AREA —
<br /> � �3 � -
<br /> A = _
<br /> EXIS7ING 6X6 COLUMN� _ — �
<br /> � ,. r,..., „�,., LIGHTING F►XTURE CONTROLS: --
<br /> � /J ��CIRCUIT PATHWAY
<br /> RECEPTIGM ���f � SWITCH (FOR HIGH BAY LIGHTS) _
<br /> / 02
<br /> � �2 DIMMABLE SWITCH (IN TREATMENT ROOM)
<br /> A A �� - �os OCCUPANT SENSOR SWITCH (IN RESTROOM AND STAFF/OfFiCE ROOMS)
<br /> r��
<br /> I X
<br /> / 4L� I ----_ _ JOB ADDRESS:
<br /> � � ---_---_
<br /> ��. �" = PNW PHYSICAL THERAPY, LLC
<br /> I � �V�,�T�vc I.iGHTwG NOTEs: 10821 19TH AV� SE, SUITE 102
<br /> � A A � 01 = t. USE ONLY UL APPROVED FIXTURES. SUBSTITUTIONS OF NON-RATED FIXTURES ARE NOT APPROVED. ELECTRICIAN ---
<br /> TO VERIFY WHETHER 120V OR 277V SOURCE IS AVAILABLE AND ORDER FIXIURES ACCORDINGLY. EVERETT WA 9H�OH
<br /> 2. LIGHT FIXTURES NEED TO BE ORDERED A.S.A.P. AS SOME HAVf LONG LEAD 11MES. LIGHTING FIXTURE SPECS ARE
<br /> CLOSET � � � � = NOT NECESSARILY COMPLEIE AND MAY REQUIRE VERIFICA710N OF NUMBER, ACCURACY AND ADDtT10NAL OPTIONS T
<br /> 07 � - COORDINATE WITH BUILDING POWER REQUIREMENTS. —
<br /> � 3. PROVIDE MUD RING AND CONDUIT CHASEWAY IN WALLS FOR I.OW-VOLTAGE CABLES.
<br /> - � �„,�;���� - APPROVAL:
<br /> 4. PROVIDE EMERGENCY AND EXIT LIGHIING PER CODE AND DIREC110N OF FlRE MARSHALL--TO BE SUBMITfED
<br /> UNDER ELECTRICAL PERMIT.
<br /> � � � � S[age Completed:
<br /> ' SOLID BLOCKING`. Signature:
<br /> 1. LOCATE BI.00KING AT EACH END OF WALL ANp ADJACENT TO REFLECTED CEILING PLAN CEILING/PLENUM NOTES&SPECIFICATIONS: -
<br /> OPENINGS.
<br /> 2. WHERE BLOCKING MATERIAL THICKNESS ALLOWS, NOTCH AND � SCALE: 3/16"=1'-0" �v 1. G4Y8 HARD LID--S/8" TYPE 'X' G.W.B. OVER 6" 20 6A. METAL STUDS, SMOOTH FINISH AND PAINTED FLAT
<br /> BEND FLANGES 90' OR ANCHOR TO VERTICALS W/ CLIP ANGLES. LATEX ENAMEL. Date:
<br /> C�IP ANGLE
<br /> ATtACHMENT TO STUD 2. OPEN CEILING EXCEPT AS NOTED GNB HARD LIDS
<br /> & BLOCKING
<br /> SOLIO BLOCKING PERMIT SET
<br /> #10 SCREW EA. '
<br /> SIDE OF STUD REFLECTED
<br /> ' , STRUC7URE (SECOND FLQOR)
<br /> Z" FLAT S1RAP EA.
<br /> SIDE LAP SPLICE 1-3/4" GYPSUM LIGHTWEIGHT POURED FLOOR CEILING PLAN
<br /> STRAPS MINIMUM 4". SOLID BLOCKING OVER 3/4" PLYWpOD
<br /> STRAPPING 3 - 10 SCREWS MIN. - - , ,,
<br /> � # TO BOTTOM O�F TRUSS_�
<br /> EA. SIDE OF BLKG. ` ' 'r ' �� '� K �`` �
<br /> CLIP ANGLE 12'-7 1/2' A.F.F. 4 � � �� ��
<br /> NOTE$: ATTACHMENT WITH '����iF� ��� -_ - � � �
<br /> 1, CONIINOUS HORIZONTAL SOUD (4}-#10 SCREWS AS 1/4" WOOD EYELAG, -TYP.
<br /> BLOCKING, BRIDGING, OR STRAPPING IS SHOWN. , 12'-7 1/2" A.F.F.
<br /> REQ'D AT ALL STEEI STUD WALLS, WITN FACTORY HANGER ROD AT �
<br /> SPACING NOT TO EXCEED 4'-0". EACH END ATTACHED WITH
<br /> CQLD-ROLLED LAG BOLT ISSUE: DATE:
<br /> CHANNEL. EXISTING TRUSSES � 2Q" o.c. UNiT LIGHTING POWER ALLOWANCE(Lt�A):
<br /> 2. WHERE BLOCKING MATERIAL THICKNESS �� PERMIT SUBMITTAL 8/31/2018
<br /> ALLOWS, NOT BEND TRACK 90' FOR ORIZONTRL BRIDGlNG _ _ 60TTO�M OF LIGHT FIXTURE � , �
<br /> C N TION. �IQ�IN� 10'-0 A.F.F.
<br /> INSTALL R-19 FOIL-FACED INSU4ATION TOTAL SQUARE FOOTAGE 2,200 $,F.
<br /> TYP.WALL BLOCK/BRIDGING 12 GA SEISMIC SPLAY WIRE BETWEEN ALL TRUSSES AND ABOVE NEW
<br /> ' (Re4'D.fOR WALLS OVER 9'-0"A.F.F.ONLY) AT EACH END OF 8 FT OFFICE AREAS REVISIONS: DATE:
<br /> FIXTURE, OPPOSITE SIDES .9 ALLOWABLE WATTS PER SQUARE FOOT .9 ---
<br /> #10 SCREWS � 8" � ---
<br /> O.C. TO CONNECT TO TOTAL ALLOWABLE WATTS 1,980 WATTS
<br /> BEAM OR JOIST
<br /> ABOVE CEILING- LINEAR PENpANT A DETA{L CEILING- INSUL.ATION BETWEEN JOISTS nPE EXEMPT EIXTURES (LOC.) LAMPS WATTS EA. COUNT wArrs
<br /> INSFALL STUDS WITH (�)-#10 G UNDER COUNTER TASK - - 3 N/A
<br /> SAME DIMENSION FOR SCREW ON Drawn ey:
<br /> T BRIDGING AIiGNMENT I EACH SIDE _ _ TO BOTTOM OF TRUSS H EXfT SIGNS = _ 6 N/A
<br /> 1 OF STUD � J EMERGENCY EGRESS LIGH7ING 5 N/A Chedced ey:
<br /> 12'-7 ]/2" A.F.F.
<br /> " (1)-#10 SGREW ON TQ BOTTOM O_�_F���_T_R�USS�
<br /> EACH SfDE OF STUD �2 7 ��2' q,F,F,� TYPE FIXTURES LAMPS WATTS EA. COUNT WA7TS
<br /> TYP. STUD TO TRACK CQNNECTION A 8 FT IWEAR PENDANT LED FIXTURES - 32 13 416
<br /> C RECESSED LED CAN UGHTS 20.2 5 101 This drawing is the exdusive property of the
<br /> UGHT GAGE STEEL STUDS PER WALL TYPE BOT. OF C�EILING
<br /> ArchitecUDesigner and may not be reproduced in part or
<br /> 9-0 A.F.F. y whole without prior written permission.
<br /> 1" DRYWALL WOOD SCREWS � 24" O.C. 36" PENDANT ROD, ADJUSTABLE 6" 20 GA STUDS � 16" O.C.
<br /> BOTTOM TRACK TO MATCH WIDTH & GAGE OF WALL STUDS RUN �N SHORTER SPAN DIRECTION
<br /> EXIT WITH 5f8" GWB ON UNDERSIDE OF CEILING
<br /> TOP OF PLYWOOD SUBFLOOR
<br /> 6" 20 GA. TRACK AT WALL. WITH
<br /> EXISTING FL00__R__ti SELF-DRILLING #10 SCREWS TOP
<br /> -- � TOTAL WATTS USED 517 WATTS
<br /> ANA BOTTOM � 16" O.C.
<br /> NQTE: LOCATE X-DNI FASTENERS WITHIN 6" AT BOTH MEETS WSEC UNIT LPA 517 < 7,980 WATTS �
<br /> SIDES OF AlL DOOR OPENINGS & TRACK SPLICES. WALLS PER PIAN �
<br /> TYP. TRACK TO FLOOR CONNECTION CEILING-EXIT LIGHT DETAIL CEILING-HARD LID FRAMING DETAIL ProjectNa.: -
<br /> Date: September 6,2018
<br /> �b��� �� �U'�����
<br /> ���:�`��..:,�;�`,0;�,� �'�� '����'�� �
<br />
|