Laserfiche WebLink
� ��: <br /> COPYRIGHT NOTICE <br /> THIS DOCUMENT AND THE INFORMATION <br /> HEREIN RELATING TO TNE PROJECT ARE <br /> AN INSTRUMENT OF SERVICE AND THE <br /> COPYRIGHTED PROPERTY OF BOTESCH, <br /> NASH AND HAL� ARCHITEC7S, P.S. NO <br /> PART HEREOF SHALL BE COPIED, <br /> , DUPLICATED, DISTRIBUTED, �ISCLOSED <br /> OR MADE AVAIIABLE TO OTHERS OR <br /> , USED TO ANY EXTENT WNATSOEVER, <br /> EXCEPT AS EXPRESSLY AUTHORIZFD IN <br /> WRITING BY BOTESCH, NASH AND HALL <br /> ARCHITECTS, P.S. <br /> � cD cfl <br /> W <br /> . Q � � � <br /> � � � <br /> Cn Z <br /> Z o <br /> O � <br /> � <br /> � � <br /> W � <br /> cn <br /> w <br /> � o <br /> r- t� <br /> � � � <br /> N � � <br /> , � � 0 <br /> Z Z <br /> --_�_r_� i_�.�.v..._.r� � � � <br /> a a a <br /> ' � <br /> � � � � <br /> _��� <br /> i <br /> i <br /> � RH � <br /> 1 — o r� <br /> t�...�_�.�: CJ oNo d�-- <br /> i ; _ �' I <br /> m.l_ la_..�.0._1 � � N <br /> "�..."`.�` <br /> � _ __ 1 � I <br /> I . � � <br /> w �.���_�; � � � � <br /> ' o � <br /> w <br /> ��.��__1 z � <br /> � ,� � ___.�__.�� �; • <br /> . �, � � � � v o . <br /> - --- �- � <br /> � o � �` v a� � o0 <br /> � � � � <br /> 30�(E) <br /> . <br /> . � � � � <br /> _ o <br /> (� W :.� ;.� � � O � cn �, <br /> �„e�_`� @ 16f�(E � N <br /> m Q � <br /> �- > I <br /> _16X8(E) Q �n <br /> � ROOF PLAN - HVAC � � <br /> � <br /> � <br /> � 0 1' 2' 4' � � <br /> A-8 `- � o <br /> � 1300(E) � A-3 � � Q <br /> � 400(E) N � <br /> _. <br /> W , _ � � SCALE: 1/8" = 1'-0" N � <br /> � _. , <br /> N : <br /> � <br /> M 12X8 E <br /> CRAWL SPACE - <br /> VENT(E) • _ . <br /> � 1 1/2"C H WS <br /> DRAW PAN PIPING WITH BALL / �`' RH 1 1/2"CHWR R I CE GR OU P, I rl C. <br /> - - ! �_ ~ Consulting Engineers <br /> VALVE, ROUTE DOWN WALL AND � -w� � <br /> TO EXIST CRAWLSPACE SUMP ' 2o2ot Cedar valley Road <br /> � �'� 600(E) �._ � W 28x240A DUCT WITH � ���owood, WA 98036 <br /> PIT. (FIELD VERIFY) X 16X8 E °O m <br /> 500(E) 16X� Q X MOTORIZED DAMPER, TRANSITION FROM 40x16 AT (425) 774-3829 (425) 672-2084 FAX <br /> N <br /> TRANSITION TO 48x24 DISCHARGE PLENUM TO 40x10 <br /> EXIST SUMP �`�---� 250 E � 250(E)�j W j �. ROOF HOOD <br /> SUPPL AIR P NUM <br /> ' (FIELD VERIFY) a A � <br /> j X ( 1 X6 0 ! 200 E) ROOF <br /> - . � _ _ e.�r�ir�. <br /> � . _ _ <br /> FROM DRAIN PAN i I� x� MOTORIZED 32x10SA ���yc��� <br /> � �� DUCTWORK IN RM 104 SHALL M � <br /> � �� DAMPER , �� �o_ �- <br /> �� 20X16X2 BE SUPPORTED FROM WALL(TYP) � <br /> PROVIDE DRAIN PANS WITH 120V � Ei e � � FILTER(E) OFFSET BELOW R-7 WRAP � �� � <br /> WATER BUG LEAK DETECTOR i j� � W 18x10SA Q � LOWER RELOCATE/ADD SPRINKLER HEADS TO INSULATION � W <br /> WITH LOCAL ALARM TO EXIST � � 4 -- 1 40x10SA i <br /> BMS PANEL FOR ALL (E)OVERHEAD i � �j j�� X �r � �- �---i ; -��� -� � PROVIDE ADEQUATE COVERAGE i � 18x8HWG � <br /> PIPING. FEILD VERfFY + � �i ► � o DRAIN PAN WITH 120V WATE PER NFPA 13 AND FM APPROVAL � 600 CFM � <br /> � 9 � BUG LEAK DETECTOR � � �' DUCTWORK IN RM 104 SHALL BE �� <br /> . j � t � 200(E) r,, �� � 8'-10' 10'-4' <br /> � � 400(E) WITN LOCAL ALARM TO P~�',. "� � 10-9 i 30x28HWG , , U <br /> i � t � �� SUPPORTED FROM WALL (TYP) I FC 2400 CFM Q <br /> � � EXIST BMS PANEL . 3/4"C WITH 1/4" PER FOOT I <br /> I �"�� �: =�-��.; � � W s� I 30x8HWG �18x8HWG HOLD 40x10 TIGHT TO BOTTOM OF BEAM � � <br /> RELOCATE(ADD SPR{NKLER HEADS I � ''.� � -�� MIN SLOPE, ROUTED THRU <br /> TO PROVIDE ADEQUATE COVERAGE � 2�0 E) �. i �(�,��250(E) � � 1 870 CFM ,600 CFM '— �� � � � <br /> !.. ��.� O 2X6 ; 1�C, � o � !�. -�- . _ _,... i .. �, � ,. ,, --� EXIST BEAM EXTERIOR WALL TO SPILL � W � <br /> ' PER NFPA 13 AND FM APPRO�Ft� � �'�' �'�' � � � - � <br /> � ��. �.�+ BALANCING `� �'' ���� 30x28 WG ', TRANSITION FROM 40x16 AT ON GRADE � � <br /> 1 DAMPER � ' DISCHARGE PLENUM TO 40x10 � � <br /> ' 14X6 E ��1 TYP. 11 (E) 6"Ql DL � �2400 FM i��� <br /> M � �, <br /> � � <br /> 26x240A TO RH-1 ABOVE � <br /> � + W �RELOCATE/ADD SPRWKLER 50 CF F OOR <br /> ,.� �__.�Y. `�.��:�: � 'HEADS TO PROVIDE ADEQUATE _ ! �� �-- .:•r•�';:.::. •.. • ,:...: . , : .. — <br /> � + DRAIN PAN PIPING WITH BALL VALVE, : .`. .`.. .._t .::L •. .s,.,....�.:�•..:,. +:,•_:.• .:�...:::•:�,:•,:'tc,.•'-�;::�., ,<• .•..�,-••. <br /> PROV(DE DRAIN PANS WITH 120V QO � � , *t i �COVERAGE PER NFPA 13 AND � � ROUTE THRU EXTERIOR WALL AND ��� �� ��� � �� � y i� � �� � � <br /> . ..: .;..,s:-..:• <br /> _.,� __._.�,�. �..1� � <br /> �� `��'�'� �`��"��' y �FM PPROVAL � -- - � � � SPILL ON GRADE Q MOTORI ED DAMPER V <br /> WATER BUG LEAK DETECTOR 0��•-m�m�m�- �, FIRE . 30x8HWG I PLENU BOX�" 2 � °� <br /> WITH LOCAL ALARM TO EXIST 300(E) I I 300(E� DAMPER � ,/ <br /> I I � 870 CFM CRETE PAD = � <br /> BMS PANEL FOR ALL(E)OVERHEAD TYP. 5(E) 6x6 HWG � 1 1/CHWS�& 1 1/2"CHWR <br /> U � <br /> PIPING. FEILD VERIFY 50 CFM 3 �- �--�-�- i TIGHT TO STRUCTURE, OUTSIDE AIR PLENUM RETURN AIR GRILLE F� � <br /> �I — <br /> M3.0 �.. ..�.m...m� DN TO FG1 __ REGULAR OPERATING MODE: �' <br /> 1 1/2"CHWS �, � � � � � <br /> EXTEND (E) SPRWKLER SYSTEM TO � � 4365 CFM RETURN AIR <br /> � 1 1/2"CHWR ( SHUT OFF VALVE � � � <br /> PROVIDE ADEQUATE COVERAGE ,� TACKED AND i (TYP OF 2) 475 CFM OUTSIDE AIR � <br /> ' PER NFPA 13 AN�D FM APPROVAL SUPPORTED ON WALL . � ` � Ur � L'�Q <br /> 1 a. _ 4,,.�. � z (v <br /> � e <br /> � _ � � � 11/2°CHWS � � LLl <br /> � 1 1/2°CHWR � - — <br /> - <br /> - --- -- - � _ ____-�------------------�---�-----_-�_-� ---- -----� 3 F C�1 E L E VAT I O N � <br /> I� � � � � <br /> a � N PROVIDE NEW 1 1/ CHWS& SCALE: 1/4" = 1'=0" � <br /> 1 1/2"CHWR WI'���RAIN PAN � Q <br /> WITH LOCAL/A �E2M�T0 EXI�T BMS PANEL <br /> � .� _ �_� - - . .�`"°..�,� __. .____ -- - <br /> .�, ---- - <br /> . <br /> �-. • ,,. � <br /> , � . __�.� ..� _ � �: � --�-- : <br /> . ---- - - a <br /> � <br /> : ��w WR�c <br /> DHC-1(E) 3-WAY CONTROL VALVE tic�,y� <br /> � �; °y <br /> � � � <br /> . <br /> . <br /> N � REDUCER(TYP) AIR VOENT IC ,p ,�,e 2qg5p � <br /> � f..�`y : /� �.� GISTERE � <br /> C� � � � C� � <br /> �-�- <br /> � <br /> .____ <br /> � (E)1" HWS & HWR � RETURN <br /> � �;�' � �j�NAL ENG <br /> � 14X12 E 1� 12 E � BALL VALVE <br /> �. : <br /> JOB. N0. <br /> � , .�� <br /> � ' (E)3" HWS & H1� p ���''`� CHILLED WATER COIL(FC-1) 16-081 <br /> � ��� � SUPPLY DATE <br /> CIRCUIT SETTER PETE'S PLUG UNION (TYP) <br /> STRAINER 09�30-2016 <br /> FLEX CONNECTION �R,awN sr <br /> PLAN (TYP) <br /> NORTH <br /> JG <br /> � FLOOR PLAN - HVAC 4 CHILLED WATER COIL PIPING DIAGRAM �"E�KE° BY <br /> • 0 1' 2' 4' SCALE: NTS CW <br /> SHEET TITLE <br /> � SCALE: 1/8" = 1'-0" <br /> FLOOR PI�N— <br /> HVAC <br /> � SHEET N0. <br /> M � c �._./ <br />