Laserfiche WebLink
GENERAL NOTES: <br /> � � � � � � A�� � � 1. REFER TO RISER DIAGRAM ON SHEET E8.21 FOR ALL NEW CONDUIT AND <br /> ,�� ..� WIRE SIZES. V <br /> � � � ��`° 2. COORDINATE AND OBTAIN APPROVAL WITH THE OWNER FOR ALL POWER �' <br /> � <br /> � � �� � � � �'°'� � �o <br /> � � � � � �� '°�µ �` `�� SHUT DOWNS REQUIRED FOR LOAD CUTOVERS. � �� <br /> � � � � � � <br /> 3. COORDINATE ALL NEW FEEDER CONDUIT ROUTiNG IN FlELD TO MINIMIZE � � o <br /> � � _ .� .� � NUMBER OF 90' BENDS. �� <br /> , ��x . , ..., <br /> �,„�.,�...., � .�����„�,�.�,�,, � <br /> c <br /> � <br /> } � ; <br /> � ; <br /> : <br /> � ��..�����.u.�,,�� .�, ,n�,.,a.��..�.. } � o � <br /> � ,�, _ �. <br /> _.� �..�.�, ��� <br /> w�� � � ��.�r_ <br /> � � � � � <br /> � 3 � ,�„� °'� 'O <br /> ATs-AE� � u a.� SUGGESTED PHASING N �o <br /> � 3 � <br /> � SWBD � � - - - - - - - , <br /> �� � � � � � � <br /> AIEMLDP2 � AtS CONTROLS CABINET PANEL GB � a ' � � k � � <br /> � o <br /> PHASE 10 0 3 <br /> ' � UNI-STRUT PANEL GX <br /> � � <br /> � � SUPPORTS � • INSTALL NEW XFMR T-AIEMLDP2 AND NEW BREAKER ON SECONDARY. � � <br /> 3 � � <br /> - - �_� - - - - - � - - - - - ATS-AX1 � � ,; �, �""`�'"""� • EXTEND FEEDER FROM XFMR TO MAIN BREAKER AND FROM MAIN BREAKER J <br /> � � � <br /> i i � i ; , �<, TO POINT NEAR NEW SWBD AIEMLDP2 WITH ENOUGH SLACK TO EXTEND TO <br /> i i � i SWBD AIEMLDP2. <br /> '"° REFER TO E1.00 <br /> - - - ,. <br /> ' � � _ � _ _ _ _ _ °- � , � FOR CONTINUATION • EXTEND PRIMARY FEEDER FROM XFMR TO A POINT WHERE CAN INTERCEPT <br /> `� 4�"'~ -- r-� FEEDER FROM EUS-EH1 TO 750KVA XFMR IN AREAWAY. <br /> � SWBD GEDS MAIN CB <br /> C�,T BKRP • LOCKOUT BREAKER IN EUS-EH1 SERVING 750KVA XFMR IN AREAWAY. <br /> , EMERGENCY POWER CONDUITS • INTERCEPT FEEDER FROM EUS-EH1 TO EXISIING 750KVA XFMR IN � <br /> i ROUTED IN THIS AREA , - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � <br /> i � � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � AREAWAY & SPUCE TO PRIMARY FEEDER TO NEW T-AIEMLDP2 � � <br /> ' � � 1 EXISIING NORMAL POWER CONDUITS • INTERCEPT FEEDER TO NEW SWBD AIEMLDP2 AND EXTEND FEEDER FROM ���� ��--9' <br /> t <br /> ; � �~ � ,' STUBBED UP IN THIS AREA NEW SWBD AIEMLDP2 MAIN BREAKER TO SWBD AIEMLDP2 AND TER NATE. � �G �f <br /> i � 5 ti <br /> � SWBD ES-1 � ,' • CLOSE BREAKER IN EUS-EH1 SERVING T-AIEMLDP2 TO RE-ESTABLISH . � r �� � <br /> ; : � - - b CIRCUIT TO SWBD AIEMLDP2. � _ °� � � <br /> i DIST PNL <br /> � - - -- - - - - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - - - -� o � <br /> �_�� �� � O <br /> - - <br /> - - � T (ECCB) �.... '������� ��'�� <br /> i - - - - - - - - i DIST PANEL � �. _. . . � �j1 44,0 <br /> XFMR _ _ � �: NUS-EH1 PRIMARY FLAG NOTES. � <br /> i ATS AC2 i - - � <br /> i i T-ES1 � � _ _ � � �� � � <br /> � , r - ---- - - - - - - - - - - - - -� 1� EXTEND FEEDER FROM NEW BREAKER FOR CUTOVER/T1E-IN. <br /> � <br /> } � - - - - � � i i <br /> �� i II III � � � i � � <br /> � ; � i � EXTEND FEEDER FROM T-AIEMLDP2 TO POINT WHERE CAN INTERCEPT EXISTING <br /> � i i FEEDER FOR EUS-EH1. <br /> �z � � � , <br /> , � , , , <br /> � � � � T � � ` � ,�°°` � �- - - - - -- - - -- - - - - - - - � ' �INTERCEPT EXISIING FEEDER TO AIEMLDP2 AND SPUCE TO NEW BREAKER. UTIUZE <br /> �`` � IN-UNE COMPRESSION LUGS FOR SPLICING. <br /> � � <br /> � k = _ _ = I � � � <br /> ; <br /> =....e <br /> � : � � i DIST PNL �'���� � NUS-EH1 �_z....�.�M,, <br /> � �_ z � XFMR � _ <br /> ECC3 � s XFMR <br /> � � i T_ECCB- - - - - (- -�- - - � � <br /> �— { — � r — — � � <br /> - - - - — I I I � � � <br /> � � <br /> i i i SWBD AICLDP2 ii i � � � <br /> ' ' i ii SWBD AIELDPI � <br /> ATS-ACl i �,.��,sr.,� . � , <br /> i i � ii i �. : AINLDPI <br /> i i ' � � `a <br /> � - - - - - - - - � � �. ; . N <br /> � <br /> � �^ ---- �� �..�.�....� <br /> „ � ��.e� � <br /> c0 <br /> A,,�, SWBD A1 CLDP1 : � - -�-----,- - - - - - , <br /> r., . � i i i o <br /> i i i <br /> � i i i � � ���. <br /> ;._ � x <br /> ��s���� x����� i i i = <br /> . i �.��. ._ . i i i <br /> � PANELi 1E � i � <br /> � 2 , - <br /> � i i � � i i <br /> � <br /> � � ,��,��..�m�z ,�,.nk i i a �� -i- - -- - � � <br /> � �� i i � ��� �� �<< � i � <br /> . __ � �, � - - - -- - - - - - - -- - - - - � 750 KVA ; �� i � <br /> �. <br /> ;� TRANSFORMER ` �` � i i � <br /> s <br /> e - - - - -- ; : s <br /> $ � , - ,�} �..�...� � i i <br /> � � I � , ...`ms.�. � . L — _ _ _ _ _ _ — _ _ _ _J �� -�� <br /> . � � Y �.. . � �� <br /> � � <br /> � � ( � � .� �'., . � <br /> t' � � <br /> �� � I I � ' � � <br /> .:. `���� � NUS-EH1 .. o <br /> ',�,�,�,. � � . _ <br /> y,: t/') <br /> ..., � � � � � � SECONDARY m.s „m�,x„-.�,.,.n,�,.�r_n�_..P.�.�__.��-.�...�.,�,� _ ,�.�. mw,��.�... z z <br /> .,,. <br /> �� � O o <br /> � NEW A1 MLDP2 � �..�. � � � � � � � _ � (n Q <br /> i�'° — <br /> � � MAIN � � � ��� :� � � "� ��,:xh� ������.����,�xu�x�.�sx�:,�,���.���=,,�.�.�,.� �.�,,�.�w....�_���:�� .��������...�. ,� , :.�. � ., .,_.:�w�,. �- ��:; <br /> � . ��r. > <br /> � ��«�.�`� �°` �' � <br /> Fv�.�w ����� <br /> ��..,�� � �� .. <br /> u...��.���,,�.� �,,a.�,�,�.�..;� � ,.� ` �,� � � <br /> , <br /> . ,�..� <br /> NEW XFMR � "� � � <br /> � <br /> T-AIEMLDP2 ..�, �.� .,..a_� �,� ,v...,�r�._a,�,x�,.���..�..�,�� ..�.�.� � <br /> �,.Fn�trx ��..� .��., , =���v. �,r�,.4.,���_.�,a� �.�,��,�,,.�,��,�x.,�,��,,�. x�a�,��,.,.,�,w. �... .,� <br /> �4 „�� � <br /> _. <br /> , . .. <br /> w <br /> � PHASE 10 ELECTRICAL ROOMS ENLARGED PLAN � o 0 <br /> E7.10 SCALf:AS INDICATED a D = � � N <br /> v 4 2 4 8 12 U J U� N <br /> 1 inch plotted Feet z � �� � <br /> If ineasurement is other than — <br /> 1 inch then the plot is reduced. Q � m Z U Iw— � <br /> � � � 00 Q � <br /> � tn U� � Q <br /> TO XFMR T-ES1 <br /> � � <br /> � Q Q I— W <br /> oo ATS-AX1 Z <br /> tD`n 400A, 4P � <br /> EMERGENCY SWITCHBOARD (ES-1) �� <br /> 1600A, 208Y/120V, 3�, 4W � � � � Q Q � E N (LIFE SAFETY) \ 1� I\ I\ U <br /> � 0 0 �.an � o0 0 ( o ( � � �¢ C �a L I F E SA F E T Y D I S TRIBUTION PANEL (LS-1) U <br /> � � � � N � N � CO°� � o N N �N 400A, 208Y/120V, 3�, 4W J J <br /> � N N � <br /> 1w W 1W 1w � � <br /> � v � � W <br /> � � � � 0 � <br /> � � � � W � � <br /> � � <br /> J � Q <br /> z � m <br /> AIEMLDP2 -- Q a = <br /> 2000A, 208Y/120V, 30, 4W � U V <br /> 65,000 AIC � 208V W m ~ <br /> SERVICE ENTRANCE RATED <br /> � J � <br /> � W �U Z <br /> SPARE SPARE SPARE "' � Z i Q <br /> I I � Z W � � <br /> m a Q <br /> � ( 1200AF (°1200AF °1200AF 1600AF o 0 <br /> 1 1200AT 1 1200AT � 1200AT � 1600AT � W Z <br /> ' TO BUS 3 W � W <br /> z � � � <br /> � 1200AF TO BUS 4 � � W a <br /> 1200AT ' <br /> EXISTING <br /> �p CHILLER #1 <br /> � ATS-AC2 ATS-AC1 ATS-AE1 <br /> o A 1600A, 4P E N E N 1600A, 4P E N 1200A, 4P <br /> A o (CRITICAL) (CRITICAL) (EQUIPMENT) <br /> N <br /> � <br /> T-A1�2 V T-GED S � o V �C <br /> 2 2500AF � c <br /> 2000AT `V O <br /> TO I I TO I I � <br /> EUS-EH1 EUS-EH1 <br /> EXISTING <br /> > 750KVA NEW AIEMLDP2 EXISTING GEDS <br /> z DRY TYPE MAIN CB 750KVA DRY TYPE MAIN CB � <br /> N TRANSFORMER TRANSFORMER �Q1 <br /> Q 480V-208Y/120V, 480-208Y/120V 1500/1680/1875 KVA, v <br /> m 3�, 4Vy 3PH, 4W KNAN/KNAN-65/KNAF � <br /> � 12.47KV:208/120V pM <br /> � _ 1600AF 1600AF �OOOAT 1200AT 800ATF �1600AT 400ATF 1200AT ~ z <br /> N 3�, 4W, 5.75� Z �F 1600AT �F 1600AT� 000 GF cF GF cF cF <br /> — �F W J <br /> � Q <br /> o SA (( J �- <br /> � K 5000AF W Q <br /> 5000AT <br /> �- 600AS O �jJ <br /> 0 600AS 150AF N r �r1 <br /> � n% <br /> W t.t_ <br /> W N.O. K K � � � <br /> i <br /> m N.c. � 1 � _ • Q J <br /> a B A — = LW <br /> c' = z <br /> � PUD SW#5 NEW NUS-EH1 HOSPITAL NORMAL POWER � <br /> � 12.47KV 5000A BUS A-WING EXISTING HOSPITAL � a- W <br /> TO EXISTING <br /> �, PUD SW#4 12.47kV//120/208V, 3�, 4W BUILDING GROUND <br /> (PARKING GARAGE) 100,000 AIC � 208V SYSTEM <br /> � SERVICE ENTRANCE RATED SH EET: <br /> �- n PHASE 10 PARTIAL ONE-LINE DIAGRAM <br /> � <br /> E7 . 10 <br /> o E�.,o <br /> � N �� <br /> / <br /> � <br />