My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6025 ROCKEFELLER AVE 2019-04-30
>
Address Records
>
ROCKEFELLER AVE
>
6025
>
6025 ROCKEFELLER AVE 2019-04-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2019 8:40:54 AM
Creation date
4/30/2019 8:40:53 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
6025
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> ,it <br /> Span Table and Footing Schedule for Decks <br /> Spans and footings assume the maximum 24"cantilever using Hem-Fir/Doug Fir No.2 or better framing lumber. Deck Connections <br /> Table uses 70 psf.loading(10 psf.dead load+60 psf live load)and 2000 psf.soil bearing pressure. (All fasteners, nails, bolts, screws and connectors must be corrosion resistant.) <br /> Joist Size <br /> Joist Max.Joist Girder Beam Size and Max.Span Between Support Posts/Footing Type Connection: Fastening: <br /> Spacing Span 4x6 Footing 4x8 Footing 4x10 Footing 4x12 Footing <br /> Manufactured Connectors Follow manufacturer's instructions <br /> 12"o.c. 7'-5" 5'-11" 14x14 7'-9" 16x16 9'-6" 18x18 11'-1" 18x18 <br /> 2x6 16"o.c. 6'-9" 5'-11" 14x14 7'-9" 16x16 9'-6" 18x18 11'-1" 18x18 Post to Footing Post base is required <br /> 24"o.c. 5'-9" 6'-3" 14x14 8'-9" 16x16 11'-0" 18x18 12'-10" 18x18Past to Footi <br /> Consult with jurisdiction about additional uplift loads where <br /> ng (High Winds) <br /> 12"o.c. 9'-7" 4'-11" 14x14 6'-6" 16x16 8'-3" 18x18 10'-0" 20x20 wind exposure is greater than Risk Category�B. <br /> 2x8 16"o.c. 8'-8" 4'-11" 14x14 6'-6" 16x16 8'-3" 18x18 10'-0" 18x18 Post to Beam Connector is required <br /> 24"o.c. 7'-7" 5'-11" 14x14 7'-9" 16x16 9'-6" 18x18 11'-1" 18x18 Ledger to House Framing See information on Sheet 5 and Sheet 6 <br /> 12"o.c. 13'-3" 3'-6" 14x14 4'-8" 16x16 5'-11" 18x18 7'-2" 18x18 <br /> ---- Joist to Beam or Girder (3) 8d —Toe nailed <br /> 2x10 16"o.c. 11'-6" 4'-1" 14x14 5'-5" 16x16 6'-11" 18x18 8'-5" 20x20 <br /> 24"o.c. 9'-5" 4'-11" 14x14 6'-6" 16x16 8'-3" 18x18 10'-0" 20x20 Blocking or Bridging to Joist (2) 10d —Toe nailed @ each end <br /> 12"o.c. 15'-5" 3'-1" 14x14 4'-1" 16x16 5'-2" 16x16 6'-3" 18x18 Wooden Deck Boards (2) 8d threaded nails OR (2) No. 8 screws <br /> 2x12 16"o.c. 13'-4" 3'-6" 14x14 4'-8" 16x16 5'-11" 18x18 7'-2" 18x18 Composite Decking Follow manufacturer's instructions <br /> 24"o.c. 10'-11" 4'-1" 14x14 5-5" 16x16 6'-11" 18x18 8'-5" 18x18 <br /> Footings must have a minimum reinforcement of(2)#4 bars each way with a 3"clearance to the bottom of the footing. <br /> Note: Footing sizes are based on decks designed with single span joists where there is no center bearing beam. <br /> Deck Ledger Connection to Band Joist a'b <br /> (Reference IRC Table R507.2-Deck live load=60 psf,deck dead load=10 psf,snow load. 40 psf) <br /> For SI: 1 inch=25.4 mm, 1 foot=304.8 mm, 1 pound per square foot=0.0479 kPa. <br /> Joist Span <br /> Connection Details 6'and less 6'1"to 8' 8'1"to 10' 10'1"to 12' 12'1"to 14' 14'1"to 16' 16'1"to 18' <br /> On-center spacing of fasteners <br /> %inch diameter lag screw with 22 16 13 11 9 8 7 <br /> 1/2 inch maximum sheathing o.d <br /> /2 inch diameter bolt with/z inch 30 22 18 15 13 11 10 <br /> maximum sheathing d <br /> /2 inch diameter bolt with 1 inch 26 19 16 13 11 10 9 <br /> maximum sheathing e <br /> a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. <br /> b. Snow load shall not be assumed to act concurrently with live load. <br /> c. The tip of the lag screw shall fully extend beyond the inside face of the band joist. <br /> d. Sheathing shall be wood structural panel or solid sawn lumber. <br /> e. Sheathing shall be permitted to be wood structural panel, gypsum board,fiberboard, lumber or foam sheathing. Up <br /> to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to %-inch of allowable sheathing <br /> thickness where combined with wood structural panel or lumbersheathing. <br /> Placement of Lag Screws and Bolts in Ledgers and Band Joists <br /> (Reference IRC Table 507.2.1) <br /> Minimum End and Edge Distance and Spacing Between Rows <br /> Top Edge Bottom Edge Ends Row Spacing /a /0 <br /> Ledger a 2 inches d 3/4 inch 2 inches b 1 5/8 inches b <br /> Band joist c 3/4 inch 2 inches e 2 inches b 1 5/8 inches b Date <br /> Residential Deck Framing Tables & Schedules <br /> For SI: 1 inch =25.4mm 2015 International Residential Code(IRC) (o/&/2018 <br /> a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run.See figure below. Sht.no. <br /> b. Maximum 5 inches. ALL, <br /> c. For engineered rim joists,the manufacturer's recommendations govern. 6454enmoreN.E.,15WA 4th S98028treet <br /> K <br /> d.The minimum distance from the bottom row to the top edge of the ledger must be in accordance with figure below. 206 919 5916 IRC3 <br /> e. 2 inches may be reduced to 3/4 inch when the band joist is directly supported by a mudsill,header,or by double top wall plates. DECKS He DOORS INC www•alldecksanddoors.com <br />