Laserfiche WebLink
4 <br /> 2� rolluda architects <br /> 105 S.Main Street Suite 323 <br /> BEESON RESIDENCE REMODEL C. J t.2066-62-A4222� <br /> 1:206-624-4226 <br /> ABBREVIATIONS GENERAL NOTES LOCATION MAP ED VICINITY MAP NED PROJECT TEAM <br /> Ati,. ;4:)!k ,' - OWNER BEESONCRAIG&JAMIEL E.R• f� <br /> ACC ACCESSIBLE ID INSIDE DIAMETER 1. DRAWINGS.THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF 411"?'" <br /> SJI,' 4' 711 RUCKER AVENUE OF W NGTON <br /> AD AREA DRAIN INCL INCLUDE,INCLUDING WORK.CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERT may '!1 ° TEL(425)258 98201.1307 <br /> ADDM ADDENDUM INFO INFORMATION - • ��`, " $'• R'- TEL(425)258-9695 <br /> ADJ ADJUSTABLE INSUL INSULATE,INSULATION THE ARCHITECT TO ANY CONFLICTS BEFORE BEGINNING WORK. • <br /> •„ �• ^� s <br /> AFF ABOVE FINISHED FLOOR INT INTERIOR • - a <br /> AHU AIR HANDLING UNIT JT JOINT 2. (E)OR'EXIST.)INDICATES EXISTING CONDITION,DIMENSION OR DATUM.VERIFY •" , •• s m r T <br /> ALT ALTERNATE KIT KITCHEN • " - .i• • - - A.ger i ARCHITECT ROLLUDA ARCHITECTS <br /> ALL EXISTING CONDITIONS AND DIMENSIONS ON PROJECT PRIOR TO 105 S MAIN ST,SUITE 323 <br /> AL ALUMINUM L LONG t <br /> MAIL MATERIAL COMMENCEMENT OF WORK. _ '4 �c <br /> ANOD ANODIZED 1?• „'..R- y ' I SEATTLE WA,98104 <br /> APPROX APPROXIMATE MB MASTER BEDROOM ::� CONTACT DONN STONE-PROJECT ARCHITECT <br /> MAX MAXIMUM 3. DO NOT SCALE DRAWINGS.THE CONTRACTOR SHALL USE DIMENSIONS ALTER • w � ••• . - donn@roludaarthitects.com <br /> ARCH ARCHITECT ARCHITECTURAL MECH MECHANICAL •" • • F t5 <br /> ASTM AMERICAN SOCIETY FOR ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS.NOTIFY THE ARCHITECT - Y;- r • 1 TEL(206)624-0222 <br /> MED MEDIUM �� • • r <br /> TESTING AND MATERIALS MEMS MEMBRANE OF ANY DISCREPANCIES WITH DRAWINGS. 1 _ S(�� FAX(206)624-0226 <br /> AUTO AUTOMATIC MEZZ MEZZANINE •[, <br /> BLDG BUILDING MFR MANUFACTURE,MANUFACTURE 4. CONTRACTOR TO VERIFY ALL DIMENSIONS,PROPERTY LINES MEASUREMENTS ,t r F • • .,� <br /> BLKG BLOCKING MIN MINIMUM,MINUTE AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK.ANY DISCREPANCIES, _ „ 4249.,,.." <br /> , � •/l- STRUCTURAL CARLA KEEL GROUP,P LL.C. <br /> BO BOTTOM OF MISC MISCELLANEOUS ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT • R-4.- - s` ENGINEER 514 S.3d,P.O.BOX 1340 <br /> ROT BOTTOM MTD MOUNTED IMMEDIATELY. •' +� .4 d •a`d' a* "�, /" t '• LACONNER,WA98257.1340 <br /> BUR BUILT UP ROOFING MTL METAL CONTACT: CARLA KEEL <br /> CI CAST IRON N NORTH «` • <br /> " • fr <br /> t pda cada roup.com <br /> CJ CONTROL JOINT NIC NOUN CONTRACT 5. TYPICAL WALL SECTIONS,FINISHES,AND DETAILS ARE NOT INDICATED • i • • . TEL:360-770-7043 <br /> CL CENTERLINE NO NUMBER EVERYWHERE THEY OCCUR ON PLANS,ELEVATIONS,AND SECTIONS.REFER TO •` � ©� " <br /> CLR CLEAR NOM NOMINAL DETAILED DRAWINGS.CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL. -• C!$ .a-• ( �i „®�®��/ <br /> COL COLUMN NTS NOT TO SCALE .« :,. .. n • ,„..: <br /> COMM COMMUNICATION OC ON CENTER 6. DETAILED AND/OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER a �'MB• �' <br /> CONC CONCRETE OH OVERHEAD - .e 5 CONTRACTOR HANBY CONSTRUCTION CO <br /> CONN CONNECTION CONNECT OD OUTSIDE DIAMETER GENERAL AND SMALLER SCALE DRAWINGS. ,,. _, - 1142ND AVENUE SOUTH,#102 <br /> CONSTR CONSTRUCTION OPNG OPENING _ • • • aL ' S,WA98020 <br /> CONT CONTINUOUS,CONTINUE OW OPPOSITE 7. GENERALLY PLAN DIMENSIONS SHOWN ARE TO FINISH OPENING,FACE OF �' ?Air <br /> . '* v • CONTACT MATT HANBY <br /> CTR CENTER ORD OVERFLOW ROOF DRAIN CONCRETE,STEEL AND FINISH FACE OF WALL,UNLESS NOTED OTHERWISE. • •1` „) • ' - 1 TELmatt@hanbyconsLcom5)672-8233 <br /> CU CUBIC OTS OPEN TO STRUCTURE ABOVE - - TEL(425)672-8233 <br /> D DEEP,DEPTH PERP PERPENDICULAR t •• ,� dl 11�L, I •'. <br /> :+ <br /> DBL DOUBLE PLYWD PLYWOOD 8. UNLESS OTHERWISE NOTED,ALL ANGLES TO BE RIGHT ANGLES,ALL LINES WHICH y,. •' (f ". �„ • f WA CONTRACTOR LICENSE:HANBYCC144B4 <br /> DEMO DEMOLISH,DEMOLITION PNL PANEL APPEAR PARALLEL ARE TO BE PARALLEL,AND ALL ITEMS WHICH APPEAR '"' •• " c ` <br /> DET DETAIL PL PROPERTY LINE CENTERED ARE TO BE CENTERED.CONTRACTOR TO BE RESPONSIBLE FOR B "' _ r' • ` r <br /> DIA DIAMETER PR PAIR PRKG PARKING MAINTAINING ALL LINES TRUE,LEVEL,PLUMB,AND SQUARE. <br /> DIAG DIAGONAL,DIAGRAM <br /> DIM DIMENSION PROP PROPERTY <br /> I. DIV DIVIDE,DIVISION PT PAINT,POINT,PRESSURE TREATED 9. NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN INSTALLATION PROJECT VICINITY PROJ ECT SITE <br /> DN DOWN R RADIUS,RISER IN VIOLATION OF APPLICABLE CODES.ALL WORK PERFORMED UNDER THIS J <br /> D.R. DINING ROOM RD ROOF DRAIN,ROAD CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, W <br /> REF REFER TO,REFERENCE <br /> DS DOWNSPOUT REGULATIONS,RESTRICTIONS,REQUIREMENTS.AND CODES OF THE GOVERNING o <br /> DWG DRAWING REINF REINFORCED,REINFORCING ry <br /> E EAST REED REQUIRED JURISDICTIONS. <br /> A (E) EXIST REV REVISED,REVISION <br /> EJ EXPANSION JOINT RFG ROOFING 10. REFER TO STRUCT.DWG FOR STRUC.MEMBERS INSTALLATION. <br /> EC <br /> RM RM <br /> EL ELEVATON 0 ROUGH OPENING PARCEL NUMBER SCOPE OF WORK DRAWING INDEX w E <br /> ELEC ELECTRIC,ELECTRICAL RT RIGHT 11. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES AND PROTECT C) cc <br /> ELEV ELEVATION S SOUTH AS REQUIRED PRIOR TO COMMENCEMENT OF WORK. 00458813600400 GENERAL Z w <br /> ENCL ENCLOSE,ENCLOSURE SCHED SCHEDULE 1. AT MAIN FLOOR REMOVE EXIST.KITCHEN APPLIANCES W O w <br /> &CABINETRY,REPLACE WI NEW&ADD A COOKING 60.01 COVER SHEET y <br /> EQ EQUAL SD STORM DRAIN 12. ALL ATTACHMENTS,CONNECTIONS,AND FASTENINGS OF ANY NATURE ARE TO BE _ w <br /> EQUIP EQUIPMENT SECT SECTION LEGAL DESCRIPTION ISLAND. 17 w�� w wD <br /> EEXHAUST PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST 2. OPEN KITCHEN TO DINING ROOM BY ELIMINATING ARCHITECTURAL In z R m z <br /> SG SAFETY GLAZING(LAMINATED) PRACTICES OF THE BUILDING INDUSTRY.DRAWINGS SHOW ONLY SPECIAL SECTION 07 TOWNSHIP 29 RANGE 05 QUARTER SE W w CO J w <br /> EXP EXPANSION,EXPOSED SGL SINGLE PORTION OF EXIST COMMON WALL. A1.01 SITE PLAN ¢°i w Q <br /> EXIST EXISTING REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. SUBDIVISION GRANDVIEW ADD TO EVERETT BLK 136 0-00-LOT 3. INSTALL NEW HARDWOOD FLOORING IN 50%OF MAIN <br /> EXT EXTERIOR SHT SHEET 4 LESS N 10FT THOF&ALL LOTS 5&6 BLK 136 SD PLAT FLOOR. REMODEL ENTRY HALL AND BATHROOM A2.01 EXIST.FLOOR PLANS&FRAMING Z w 3 a w <br /> SHTHG SHEATHING A2.02 (NOT USED) ro U <br /> FA RRE ALARM SIM SIMILAR 13. CONTRACTOR SHALL COORDINATE THE WORK FOR ALL TRADES FOR OPENINGS INCLUDING UPGRADE OF FIXTURES. O U 0 <br /> FCIO FURNISHED BY CONTRACTOR/SPEC SPECIFICATION THROUGH ROOF AND WALLS FOR PIPES,CONDUITS,AND EQUIPMENT. 4. ADD CLOSET IN MASTER BEDROOM UNDER SLOPED A2.03 DEMOLITION FLOOR PLANS W n z z CO, <br /> INSTALLED BY OWNER SPKLR SPRINKLER PROJECT CODE INFORMATION ROOF, A2.04 EXIST.ROOF PLAN,WINDOW&DOOR TYPES/SCHEDULE W �w w ¢� <br /> FDC FIRE DEPARTMENT 50 SQUARE 14. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER,INCLUDING:SITE 5. REPLACE OR RELOCATE SELECT WINDOWS A2.05A STRUCTURAL NOTES&BASEMENT PLAN cQ r.w o U r� <br /> CONNECTION SS STAINLESS STEEL JURISDICTION: EVERETT A2.05 FLOOR PLAN REVISIONS&NEW FRAMING <br /> FF FACTORY FINISH STD STANDARD ACCESS,MATERIALS STORAGE,AND STAGING,INTERRUPTION OF ELECTRICAL <br /> FIG FIGURE STL STEEL AND MECHANICAL SERVICES AND TIMING OF NOISY AND DISRUPTIVE OPERATIONS. APPLICABLE CODES: 2015 INTERNATIONAL RESIDENTIAL CODE A3.01A FRAMING SECTIONS&DETAILS REVISION G..TE <br /> FIN FINISH,FINISHED STOR STORAGE CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER. 2015 INTERNATIONAL FIRE CODE A3.01 BUILDING SECTIONS&DETAILS <br /> FLEX FLEXIBLE STRUCT STRUCTURAL 2015 NATIONAL ELECTRICAL CODE A4.01 EXTERIOR ELEVATIONS - - <br /> FO FACE OF SUSP TONGUE 15. CONTRACTOR TO PROTECT EXISTING FURNISHINGS,FIXTURES,EQUIPMENT AND 2015 UNIFORM PLUMBING CODE <br /> T&G <br /> FOIC FURNISHED BY OWNER/ T&G TONGUE AND GROOVE 20151NTERNATIONAL ENERGY --- <br /> INSTALLED BY CONTRACTOR TBD TO BE DETERMINED LANDSCAPING FROM DAMAGE.CONTRACTOR TO REPLACE IN KIND ANY SUCH -- <br /> FR FRAME,FIRE RATED TEMP TEMPERATURE,TEMPORARY ITEMS DAMAGED. ZONING DESIGNATION: NORTHWEST EVEREST <br /> FRMG FRAMING TG TEMPERED GLAZING - Design: D.S. <br /> FRT FIRE RETARDANT TREATED THK THICK,THICKNESS 16. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR ARCHITECT'S CONSTRUCTION TYPE: V-B Drawn: FA <br /> FT FOOT,FEET TO TOP OF PERIODIC REVIEW. <br /> FTG FOOTING UP TYPICAL Checked: G.K <br /> GA GAGE,GAUGE UON UNLESS OTHERWISE NOTED OCCUPANCY TYPE: R-1 <br /> GALV GALVANIZED VERT VERTICAL Project No. <br /> GEN GENERAL VIN VINYL NUMBER OF STORIES: (2)STORIES+BASEMENT <br /> GWB GYPSUM WALL BOARD VR VAPOR RETARDER <br /> Issuance <br /> GYP GYPSUM W WEST,WIDE <br /> GYP HIYPSUMBOARD IGH W/O WITH <br /> PERMIT SET <br /> HORIZ HORIZONTAL WD WOOD <br /> HR HOUR WP WEATHERPROOF,WATERPROOF, <br /> HT HEIGHT WATERPROOFING,WORK POINT <br /> Date: 04/05/2017 <br /> HVAC HEATING,VENTILATING, WR WATER RESISTANT <br /> AND AIR CONDITIONING WT WEIGHT Drawing Title <br /> REFERENCE SYMBOLS <br /> s n x - A 0 COVER SHEET <br /> SECTION DETAIL INDICATOR <br /> BUILDING SECTION INDICATOR I DRAWING REVISION INDICATOR Drawing Number <br /> COLUMN GRIDLINE INDICATOR <br /> A. <br /> ® , G0.01 I dip <br /> --, FLAGNOTE ELEVATION INDICATOR <br /> SECTION INDICATOR ENLARGED DETAIL INDICATOR <br />