• <br /> GENERAL STRUCTURAL NOTES <br /> (The following apply unless shown otherwise on the plans) <br /> rolluda architects <br /> - ALL WOOD PLATES,LEDGERS,AND BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY 105 S.Main Street Suite 323 V <br /> CRITERIA SHALL BE PRESSURE-TREATED WITH AN AMERICAN WOOD PRESERVERS ASSOCIATION(AWPA) Seattle,WA 98104 <br /> APPROVED PRESERVATIVE.ALTERNATIVELY,PER IBC SECTION 2304.12,FOR SOME EXCEPTIONS, t.206-624-4222 <br /> ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE IMPERVIOUS MORSTURE BARRIERS MAY BE PROVIDED BETWEEN UNTREATED MEMBERS AND <br /> t 206-624-4226 <br /> DRAWINGS,SPECIFICATIONS,THE INTERNATIONAL BUILDING CODE(2015 EDITION).. CONCRETE OR MASONRY.ALL CONNECTORS USED WITH PRESSURE-TREATED WOOD SHALL HAVE <br /> A 0185 GALVANIZED COATING OR BE STAINLESS STEEL. <br /> DESIGN LOADING CRITERIA <br /> TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE BY SIMPSON STRONG-TIE <br /> LIVE LOADS: COMPANY,INC AS SPECIFIED IN THEIR CURRENT CATALOG.EQUIVALENT DEVICES BY OTHER <br /> USD <br /> MANUFACTURES MAY BE SUBSTITUTED,PROVIDED THEY HAVE CURRENT ICC-ES EVALUATION / r <br /> ROOF 25 PSF(SNOW) REPORTS DEMONSTRATING THAT THE PRODUCTS HAVE EQUAL OR GREATER LOAD CAPACITIES. , %� .�6-'e <br /> FLOOR 40 PSF PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER.CONNECTORS /7///' j /I�%, / <br /> SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. /i�.E .14/ <br /> SNOW LOAD: 25 PSF(NON-REDUCIBLE);SNOW DRIFT LOAD- WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS,PLACE ONE-HALF OF THE NAILS OR BOLTS TATE OF ASHINGTON <br /> ASCE 7-10 IN EACH MEMBER.ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307.PROVIDE <br /> WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. <br /> WIND LOAD: BASED ON BASIC WIND SPEED 110 MPH, UNLESS NOTED OTHERWISE,ALL NAILS SHALL BE COMMON.ALL SHIMS SHALL BE SEASONED AND <br /> EXPOSURE"B",IMPORTANCE FACTOR 1.0, DRIED AND THE SAME GRADE(MINIMUM)AS MEMBERS CONNECTED. <br /> BUT WIND AREA FOR STRUCTURE NOT CHANGED, <br /> NO ANALYSIS PROVIDED. <br /> ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM O O O <br /> SEISMIC LOADS: STRUCTURE NOT CHANGED FOR SEISMIC LOADS. STANDARDS OF THE INTERNATIONAL BUILDING CODE(2015).MINIMUM NAILING,UNLESS OTHERWISE <br /> NO ANALYSIS PROVIDED. NOTED,SHALL CONFORM TO TABLE 2304.10.1 OF THE IBC.UNLESS NOTED OTHERWISE,ALL NAILS <br /> WOOD WALLS WILL BE CONNECTED TO FOUNDATION SHALL BE COMMON.COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL 32'-0" <br /> VOLUNTARILY FOR SEISMIC PERFORMANCE Z IMPROVEMENT. AND ARCHITECTURAL DRAWINGS.PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS i <br /> AND LAG SCREWS BEARING ON WOOD. 2'-10" 2V-2" <br /> I t f <br /> WALL FRAMING-ALL STUDS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16"O.C. <br /> CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL AT INTERIOR WALLS AND 2x6 @16"MIN.O.C.AT EXTERIOR WALLS.TWO STUDS MINIMUM SHALL BE <br /> COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS.(2)2X8 HEADER SHALL <br /> PLANS. BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED.SOLID BLOCKING FOR WOOD <br /> COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW.PROVIDE CONTINUOUS I I I <br /> DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 8'-0"IN HEIGHT.ALL STUD WALLS SHALL, <br /> NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 12"(q\ • _ <br /> DETAILS OF CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND APPROVAL BY THE O.C.STAGGERED OR BOLTED TO CONCRETE WITH 5/8"DIAMETER ANCHOR BOLTS @ 4'-0"O.C.WIT <br /> ARCHITECT AND THE STRUCTURAL ENGINEER. INCH MIN.EMBEDMENT UNLESS INDICATED OTHERWISE.GALVANIZED PLATE WASHERS OF A MIN. <br /> OF 3 INCHES BY 3 INCHES BY 1/4 INCH THICK SHALL BE USED ON EACH ANCHOR BOLT.INDIVIDUAL <br /> ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d @ 12"O.C.STAGGERED. I <br /> SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING,DELIVERY,HANDLING, REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. <br /> STORAGE AND ERECTION IN ACCORDANCE IMTH INSTRUCTIONS PREPARED BY THE SUPPLIER. ' 2X10@16"OC 112X10@t6"OC ' <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, <br /> TECHNIQUES,SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. WOOD FASTENERS: - I <br /> A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: <br /> EPDXY-GROUT SHALL BE SIMPSON SET-XP OR APPROVED EQUAL.ALL DRILLED AND GROUTED SIZE LENGTH DIAMETER v <br /> REINFORCING BARS OR BOLTS SHALL BE EPDXY GROUTED UNLESS OTHERWISE NOTED.EPDXY 8d 2-3/8" 0.113' c) <br /> SHALL BE MIXED,APPLIED AND CURED IN STRICT ACCORDANCE WITH ICC REPORT.ALL PLACEMENT 10d 3° 0.148" 7 2X4 <br /> AND CURING SHALL BE CONDUCTED WITH CONCRETE AND AIR TEMPERATURES ABOVE 50 12d 3° 0.148" N \ J <br /> DEGREES.APPLY EPDXY ONLY TO CLEAN,DRY CONCRETE.HOLE SIZE SHALL BE IN ACCORDANCE 16d 3" 0.131" LU <br /> WITH THE MANUFACTURER'S REQUIREMENTS.PROVIDE POSTIVE PROTECTION SO DOWELS ARE IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS,THEY SHALL SUBMIT NAIL Q b <br /> NOT DISTURBED DURING THE CURING PERIOD.NO REINFORCMENT SHALL BE CUT TO INSTALL SPECIFICATIONS TO THE STRUCTURAL ENGINEER(PRIOR TO CONSTRUCTION)FOR REVIEW AND / O c, <br /> DOWELS. APPROVAL. °i <br /> • 2X4 E 3 <br /> GROUTING REINFORCING BARS AND BOLTS INTO EXISTING CONCRETE SHALL BE ACCOMPLISHED W IT, <br /> BY DRILLING HOLES INTO EXISTING CONCRETE.HOLES MAY BE CUT BY EITHER ROTARY _ U rc <br /> PERCUSSION DRILLING FOLLOWED BY AIR BLOWOUT WITH OIL-FREE COMPRESSED AIR OR -' Z w <br /> DIAMOND CORE BORING FOLLOWED BY WATER FLUSH.THE CONTRACTOR SHALL CHIP AWAY A . W O w <br /> SUFFICIENT QUANTITY OF CONCRETE COVER OVER EXISTING REINFORCING TO ASSURE HOLE I 0 ui w LD <br /> i <br /> LOCATIONS CLEAR EXISTING REINFORCING. © . - - <br /> - _ 6X10 DF#1 _ 8"CONCRETE z N m z <br /> v STAIR FOUNDATION CC a m w Q <br /> WooD STRUCTURAL FLAG NOTES UP® FRAME z W 3 a Y <br /> 1 O Y <br /> FRAMING LUMBER SHALL BE KILN-DRIED OR MC-15,AND GRADED AND MARKED IN CONFORMANCE 21 2 STUDS MIN,TYP.AT THE END OF BEAMS AND HEADERS G` �� I 4 1- <br /> W it z 05 0 <br /> 0 D <br /> WITH W.C.L.B.STANDARD GRADING RULES FOR WEST COAST LUMBER NO.16,LATEST EDITION. O - —r—�—� - — — W w w ¢_ <br /> FURNISH TO THE FOLLOWING MINIMUM STANDARDS: S2 ADD FLOOR 2X10 FLOOR JOIST UNDER NEW WALL 2X4 2X4 co ^w U U r� <br /> POSTS AND TIMBERS DOUG FIR N0.1 ABOVE UNLESS THERE IS AN EXISTING 2X10 JOIST <br /> PRESENT DIRECTLY UNDER WALL REVISION DATE <br /> 2x JOISTS AND BUILT-UP EXISTING HOUSE WALLS ARE TO BE CONNECTED TO - <br /> MEMBERS DOUG FIR NO.2 S3 FOUNDATION-PLATE TO EXISTING FOUNDATION WALLS <br /> N U <br /> BEAMS DOUG FIR NO.2 WITH SIMPSON UFP OR SIMILAR CORNER AND AT 6 0•3 p <br /> FEET ON CENTER FOR SEISMIC IMPROVEMENT t 0-' io <br /> 0 <br /> STUDS,PLATES,MISC. N N o Design: DS <br /> LIGHT FRAMING DOUG FIR OR HEMFIR STANDARD GRADE g7 i✓ X Drawn: FA vii <br /> BOLTED STUDS,LEDGERS S4 ADD BEAM TO SUPPORT REMOVED BEARING WALL N <br /> AND PLATES DOUG FIR OR HEMFIR STANDARD GRADE ABOVE-CONTRACTOR VERIFY FRAMING Checked: z <br /> _ Project No. F- <br /> OD <br /> PLYWOOD SHEATHING SHALL BE GRADE C-D,EXTERIOR GLUE OR STRUCTURAL I,EXTERIOR GLUE • • Issuance 0 <br /> IN CONFORMANCE WITH THE IBC.ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, N <br /> EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. PERMIT SET <br /> ROOF SHEATHING SHALL BE 15/32"WITH PANEL INDEX 24/0. <br /> w <br /> FLOOR SHEATHING SHALL BE 23/32"IMTH PANEL INDEX 32/16. Date: 04/05/2017 U <br /> co <br /> WALL SHEATHING SHALL BE 15/32"WITH PANEL INDEX 24/0. - BASEMENT PLAN AND 1ST FLOOR FRAMING Drawing Title mI <br /> REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING. SCALE:1/4•=1•-0'. STRUCTURAL c <br /> NOTES & <br /> BASEMENT PLAN <br /> Drawing Number <br /> • <br /> A2.05A JO <br /> ggrnamR:Rr•M1>ROLLOOr ARCHITECTS INC <br />