Laserfiche WebLink
N <br /> V <br /> X <br /> � S�R A�c� �t�ct� <br /> M <br /> W <br /> N <br /> � <br /> � 1402 3rd Ave Suite 730 <br /> z <br /> � Seattie, WA 98101 <br /> � <br /> U <br /> O <br /> � MECHANICAL NOTES GENERAL NOTES PIPING SYMBOLS DUCTWORK SYMBOLS GENERAL SYMBOLS ABBREVIATIONS <br /> J <br /> a � B�G <br /> z <br /> � —;W�— BALL VALVE DUCT SECTION -SUPPLY p-� PLUMBING FIXTURE ADA AMERICANS WITH DISABILITIES ACT �� y�'v�� <br /> 0 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. tNSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING � IDENTIFICATION AFF ABOVE FINISHED FLOOR � z <br /> ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH PER I.B.C. REQUIREMENTS. BALANCING VALVE ARCH. ARCHITECT/ARCHITECTURAL <br /> MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWiNG. � DUCT SECTION - RETURN �'� <br /> INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. ��� BUTTERFLY VALVE M-1 EQUIPMENT CD CEILING DIFFUSER � � <br /> IDENTIFICATION 2736 �, <br /> 2. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND �� CHECK VALVE 20x12 RECTANGULAR DUCT(INSIDE DIMENSION) CG CEILING GRILLE ��,c�F SFGISTER NG��� <br /> DIFFUSERS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT ,'�� CLEAN OUT KITCHEN FIXTURE CO CLEANOUT S ONAL E <br /> ELEVATIONS FOR EXACT LOCATIONS. NECESSARILY REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. ���_ 20"� ROUND DUCT K-� IDENTIFICATION COP COEFFICIENT OF PERFORMANCE <br /> CONTROL VALVE-2 WAY CONT. CONTINUATION <br /> 3. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDiCATED BY THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO � CONTROL VALVE-3 WAY DWG DRAWING DRAWN BY <br /> DRAWINGS, REQUIRED BY CODES OR RECOMMENDED BY MANUFACTURER BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY —'�''— I FLEX CONNECTION J K <br /> ARE PROVIDED. EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, DEMOLISHED 1TEM AIR TERMINAL MARK �E) EXISTING ITEMS CHECKED BY <br /> ------------- <br /> PIPES, UTILITIES AND BUILDING STRUCTURE. ,�..�, L20x12 LINED DUCT(INSIDE DIMENSION) EA EXHAUST AIR <br /> 4. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN AND EXHAUST FLOW METER - - - - - - - TYPE (SEE EAT ENTERING AIR TEMP. LWB <br /> OPENING, IN SUPPLY BRANCH WHERE THREE OR MORE OPENINGS ARE VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. FLEX CONNECTION L12x10 LINED DUCT (INSIDE DIMENSION) X SCHEDULE) EER ENERGY EFFICIENCY RATING APPROVED BY <br /> ASSOCIATED WITH THE BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS F = __ _ _ __ � 200�� EFF EFFICIENCY/ EFFICIENT <br /> OR IN SPECIFICATIONS. CONTRACTOR SHALL PROVIDE WASTE, VENT, WATER AND GAS PIPING, GATE VALVE DESIGN CFM ELECT. ELECTRICAL <br /> INCLUDING TRAPS, FITTINGS AND STOPS TO COMPLETE EACH EQUIPMENT -�,r- PRESSURE REDUCING VALVE � � � 9 0° C O N I C A L S P I N-I N F I T T I N G FCO FLOOR CLEANOUT <br /> 5. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, HOOK-UP TO THE POINT OF FINAL CONNECTION. CONNECTION BETWEEN : DETAIL REFERENCE IPLV INTEGRATED PART LOAD VALUE <br /> ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND VARIOUS PIECES OF EQUIPMENT SHALL BE MADE BY THE PLUMBING PRESSURE RELIEF VALVE FLEXIBLE DUCT <br /> DETAIL NUMBER I.E. INVERT ELEVATION <br /> GENERAL PIPE ROUTING ONLY. PROVIDE PIPING SHOP DRAWINGS CONTRACTOR AT THE TIME EQUIPMENT IS BEING INSTALLED. RPBP REDUCED PRESSURE - �� TURNING VANE � LAT LEAVING AIR TEMP. <br /> COORDINATED WITH OTHER TRADES. REFER TO SPEC. FOR ADDITIONAL SHOP BACKFLOW PREVENTER � LF LINEAR FOOT <br /> DRAWING REQUIREMENTS. M2'3 DRAWING ON WHICH <br /> THERMOMETER � CEILING DIFFUSER DETAIL IS LOCATED MC MECHANICAL CONTRACTOR <br /> -�I�--- UNION <br /> MECH. MECHANICAL <br /> a RETURN/EXHAUST/ NP NON POTABLE <br /> - - - - - - - - - VENT TRANSFER GRILLE OR REGISTER SECTION REFERENCE OSA OUTSIDE AIR <br /> WASTE � VOLUME DAMPER SECTION ID RG C R�ETURNF RE�LIEF GRI�LNE <br /> _ COLD WATER( DOMESTIC ) � �" <br /> _ _ HOT WATER( DOMESTIC ) � MOTORIZED DAMPER A SA SUPPLY AIR <br /> M2.3 DRAWING ON WHICH SENS SENSOR <br /> _ _ _ HOT WATER RECIRC. ( DOMESTIC ) COMBINATION SMOKE/FIRE DAMPER SECTION IS LOCATED SG SUPPLY GRILLE <br /> D CONDENSATE DRAIN T'STAT THERMOSTAT <br /> DUCT SMOKE DAMPER TW TEMPERED WATER <br /> F FIRE SPRINKLER PIPE Q REVISION TyP TYPICAL <br /> � NATURAL GAS -4 BACKDRAFT DAMPER IDENTIFICATION U.O.N. UNLESS OTHERWISE NOTED <br /> V VENT <br /> -+� PIPE DOWN �T THERMOSTAT � FLAG NOTE VTR VENT THROUGH ROOF <br /> DUCT INSULATION SCHEDULE ---�o PIPE UP <br /> � HOSE BIBB/WALL HYDRANT � SENSOR WCO WALL CLEANOUT <br /> DUCT TYPE DUCT LOCATION INSULATION OTHER REQUIREMENTS C CO2 SENSOR <br /> R-VALUE —�a�� HOSE DRAIN VALVE � <br /> NOT WITHIN CONDITIONED SPACE: o VENT THROUGH ROOF <br /> SUPPLY, RETURN ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC IN ENCLOSED R-7 APPROVED WEATHER PROOF BARRIER p FLOOR DRA►N DRAWING INDEX <br /> CEILING SPACE, IN WALLS, IN GARAGE , IN CRAWL SPACES. <br /> � FLOOR SINK <br /> DWG. DESCRIPTION <br /> OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE R-7 PER THE W.S.E.C. SECTION 1414.2 SPRINKLER HEAD- PENDANT <br /> � SPRINKLER HEAD- UPRIGHT M0.01 MECHANICAL LEGEND, NOTES AND SCHEDULES <br /> SUPPLY, RETURN, NOT WITHIN CONDITIONED SPACE: M1.01 PARTIAL FOUNDATION AND FIRST FLOOR PLUMBING PLANS <br /> OUTSIDE AIR INTAKE IN CONCRETE, IN GROUND R-5.3 <br /> M2.01 PARTIAL FIRST FLOOR HVAC PLANS <br /> SUPPLY WITH SUPPLY AIR M3.01 MECHANICAL SECTIONS, DETAILS AND DIAGRAMS Z <br /> TEMPERATURE <55°F OR>105°F WITHIN CONDITIONED SPACE R-3.3 MD2.01 PARTIAL FIRST FLOOR MECHANICAL DEMOLITION PLANS O <br /> � <br /> NOTE: REQUIREMENTS APPLY TO THE DUCT TYPE LISTED, WHETHER HEATED OR MECHANICALLY COOLED. MECHANICALLY COOLED DUCTS a <br /> REQUIRING INSULATION SHALL HAVE A VAPOR RETARDER, WITH A PERM RATING NOT GREATER THAN 0.5 AND ALL JOINTS SEALED. (� <br /> 0 <br /> J <br /> HOT WATER HEATER SCHEDULE PLUMBING FIXTURE SCHEDULE W <br /> �C <br /> EQUIP. CAPACiTY, CAPACITY, ELECTRICAL TAG ITEM DESCRIPTION W V CW HW TW REMARKS � <br /> STORAGE RECOVERY TEMP. MANUFACTURER WEIGHT, W <br /> N0. SERVICE GAL. KW. TEMP. F. GPH RISE, F. & MODEL VOLTS PHASE �BS REMARKS � <br /> DW-1 � DISHWASHER 2" - - 1/2" - O.F.C.I. � � <br /> HWT-2 CRITTER ROOM 151 /STAFF KITCHEN 150 50 13.5 120 79 65 A.O. SMITH DRE-52-13.5 208 3 260 Z � <br /> EWS-1 p�p EMERGENCY EYE WASH INDIRECT - - - 1-1/4" � <br /> STATION/SHOWER W � O <br /> S-1 � SINK, SINGLE 1-1/2" 1-1/2" 1/2" 1/2" - � � _ <br /> SINK „ W LL � <br /> EXPANSION TANK SCHEDULE S'2 TWOCOMPARTMENT 2 INDIRECT - 1/2" 1/2" - O.F.C.i. � � <br /> � <br /> � <br /> EQUIP. CAP. WEIGHT, MANUFACTURER o <br /> N SERVICE LBS REMARKS S-3 � SINK, UTILITY 2" 2" 1l2" 1l2" - _ � � � <br /> 0 GAL (EMPTY) & MODEL O m J � <br /> ET-2 HWT-2 2.1 10 AMTROL MFG. CO I ST-5-C FD-1 O FLOOR DRAIN 2" 1-1/2" - - - O.F.C.I., PROVIDE TRAP PRIMER � J m O <br /> W = F- <br /> FS-1 � FLOOR SINK 3" 2" - - - O.F.C.I. � �' � <br /> w ? <br /> � � _ <br /> CWB-1 O CLOTHES WASHER BOX 2" 1-112" 1/2" 1/2" - O.F.C.I. � Z �' j Q <br /> „ w z W W = � <br /> RB-1 ❑ REFRIGERATOR BOX - - 3/8 - - O.F.C.I. � W � � � � <br /> z — W � w <br /> WVO > oW <br /> ° tn I-- W � W <br /> a <br /> PROJECT NO. <br /> 1731 <br /> ISSUE DATE <br /> HVAC DUCT SPECIFICATION WSEC 1 / 8 / 2018 <br /> ( i CURRENT REVISION <br /> \ I <br /> PERMIT SUBMITTAL <br /> .� SEISMIC NO. REVISION DESCRIPTION DATE <br /> U <br /> �' FLEX CONNECTION CLEANLINESS DURING LINING IMPORTANCE <br /> � <br /> o Q DUCT SYSTEM PRESSURE CLASS DUCT MATERIALS FITTINGS FLEX DUCT SEAL CLASS CONSTRUCTION INSULATION MATERIALS FACTOR NOTES <br /> .�� HVAC LOW PRESSURE SUPPLY; SMACNA+ 12/" OR+1" PRESSURE GALVANIZED DUCT; GAUGE AND ELBOWS: PURCHASED ADJUSTABLE ELBOWS 8' MAXIMUM LENGTH WITH NO OFFSETS SMACNA SEAL CLASS FOLLOW BASIC "LEVEL A" SMACNA WITHIN CONDITIONED SPACE: R3.3 PROVIDE 1" INTERIOR LINING WHERE IP=10 <br /> 0 o FURNACE TO AIR TERMINALS REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" USE THERMA FLEX, GKM OR EQUAL LEVEL C SMACNA NOT IN CONDITION SPACE: R-7 INDICATED ON PLANS <br /> � � OR BETTER STANDARDS 1/2" NO SEAL WITH APPROVED SHAPER/WEATHER <br /> � .o <br /> � `° SMACNA+ 12/" OR+1" PRESSURE SMACNA+ 12/"OR+1" PRESSURE SMACNA+ 12/" OR+1" PRESSURE BARRIER <br /> .N L <br /> �� ROUND MAY BE SNAPLOCK LARGER THAN 24 INCHES UNDERGROUND OR IN CONCRETE: R5.3 <br /> � `° CONICAL SPIN-IN FITTINGS ON ROUND <br /> � � <br /> � .L' BRANCHED DUCTS <br /> �� � OUTSIDE AIR INTAKE SMACNA+2" GALVANIZED DUCT; GAUGE AND ELBOWS: PURCHASED ADJUSTABLE ELBOWS FLEX AT EQUIPMENT CONNECTIONS TO SMACNA SEAL CLASS FOLLOW BASIC "LEVEL A" WITHIN CONDITIONED SPACE: R3.3 PROVIDE 1" INTERIOR LINING WHERE IP=10 <br /> � y LOUVER/PLENUMS REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" COMPLY WITH SPEC APPLICABLE PRESSURE LEVEL C SMACNA NOT IN CONDITION SPACE: R-7 INDICATED ON PLANS <br /> o � <br /> �-y DUCT UPSTREAM OF MOTORIZED OR BETTER STANDARDS CLASS WITH APPROVED SHAPER/WEATHER <br /> � � DAMPERS RECTANGULAR MAY BE S DRIVE CL RADIUS OF 1.0 DIAMETER ON DUCTS BARRIER <br /> C U <br /> � -o ROUND MAY BE SNAPLOCK LARGER THAN 24 INCHES UNDERGROUND OR IN CONCRETE: R5.3 <br /> �' � CONICAL SPIN-IN FITTINGS ON ROUND <br /> � L <br /> C � <br /> � o BRANCHED DUCTS <br /> � = EXHAUST SMACNA-1/2"OR-1" PRESSURE GALVANIZED DUCT; GAUGE AND ELBOWS: PURCHASED ADJUSTABLE ELBOWS 8' MAXIMUM LENGTH WITH NO OFFSETS SMACNA SEAL CLASS FOLLOW BASIC "LEVEL A" NOT REQUIRED PROVIDE 1" INTERIOR LINING WHERE IP=10 <br /> � � <br /> �� � LOW PRESSURE REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" USE THERMA FLEX, GKM OR EQUAL LEVEL C SMACNA INDICATED ON PLANS <br /> � Q OR BETTER STANDARDS FLEX AT EQUIPMENT CONNECTIONS TO <br /> �' RECTANGULAR MAY BE S DRIVE CL RADIUS OF 1.0 DIAMETER ON DUCTS COMPLY WITH SPEC APPLICABLE PRESSURE <br /> � �� MECHANICAL <br /> �- � ROUND MAY BE SNAPLOCK LARGER THAN 24 INCHES CLASS <br /> .� � CONICAL SPIN-IN FITTINGS ON ROUND LEGENDS, NOTES <br /> �.= BRANCHEDDUCTS AND SCHEDULES <br /> � � VOLUME DAMPERS N/A SMACNA REQUIREMENTS N/A N/A PER APPLICABLE PER APPLICABLE N/A N/A N/A SCALE AS NOTED <br /> � Q DUCT SYSTEM DUCT SYSTEM <br /> �' o <br /> c� � <br /> a� �. <br /> � o <br /> a� � <br /> � � <br /> � � <br /> � c <br /> co � <br /> c � <br /> � U <br /> � � <br /> � � <br /> U L <br /> O Q <br /> � <br /> � � <br /> H � � <br />