Laserfiche WebLink
� _ . _ __ __ _ _ _ _ _ __ <br /> N <br /> , � <br /> X <br /> w �"�� ��'C�11��Ct� <br /> N <br /> � <br /> � 1402 3rd Ave Suite 730 <br /> z <br /> � Seattle, WA 98101 <br /> � <br /> U <br /> O <br /> 0 <br /> J <br /> Q O <br /> z <br /> � pF' AS <br /> � <br /> , O � � � <br /> O � r <br /> � � r <br /> �. <br /> ELECTRICRL SYMBOLS ELECTRICAL ABBREVIATIONS �������GI ER����w� <br /> SI AL � <br /> LIGHTING RECEPTACLES SPECIAL SYSTEMS AF AMPERE FRAME FACP FIRE ALARM CONTROL PANEL PS PROJECTION SCREEN 1I16/2018 <br /> AFF ABOVE FlNISHED FLOOR FDMPR FIRE DAMPER PTR PRINTER DRAWN BY <br /> LUMINAIRE: � DUPLEX RECEPTACLE - NEMA 5-15R (NEMA 5-20R FOR DEDICATED CIRCUIT) FlRE ALARM AHU AIR HANDLING UNIT FH FUME HOOD PVC POLYVINYL CHLORIDE (PIASTIC) <br /> xx XX - IUMINAIRE TYPE AIC AMPERE INTERRUPTING CURRENT FMT FLEXIBLE METALLIC TUBING PWR POWER CE) <br /> � YY - CIRCUIT NUMBER �AC DUPLEX RECEPTACLE - ABOVE COUNTER. COORDINATE W/ ARCH. ELEVATIONS I-QF MANUAL PULL STATION WITH GUARD CHECKED BY <br /> XXE - LUMINAIRE TYPE ENDING iN E AMP AMPERE FU or F FUSE QTY QUANTITY <br /> w INDICATE BATTERY BACKUP �p DUPLEX RECEPTACLE - DEDICATED (NEMA 5-20R) �4 HORN/STROBE AS AMPERE SWITCH FVNR FULL VOLTAGE NON-REVERSING RA FAN RETURN AIR FAN JLM <br /> ASV AIR SOLENOID VALVE G GROUND RECPT RECEPTACLE APPROVED BY <br /> � LUMINAIRE ON EMERGENCY CIRCUIT �WP DUPLEX RECEPTACI.E - WEATHERPROOF � HORN/STROBE - CEILING MOUNT AT AMPERE TRIP GALV GALVANIZED REF REFRIGERATOR PW J <br /> ATS AUTOMATIC TRANSFER SWITCH GC GOGGLE CABINET REQD REQUIRED <br /> �-� DUPLEX RECEPTACLE - TAMPER RESISTANT �I STROBE AWG AMERICAN WIRE GAUGE GD GARBAGE DISPOSAL RH RANGE HOOD <br /> � EXIT SIGN, CEILING MOUNT <br /> REFER TO ARCHITECTURAL �FE SAFETY �GFCI DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER � STROBE - CEILING MOUNT BAS BUILDING AUTOMATION SYSTEM GEC GROUNDING ELECTRODE CONDUCTOR RMC RIGIO METAL CONDUIT CQFFMAN <br /> PLAN FOR DIRECTION OF TRAVEL BBO BACKBOARD OPERATOR GEN GENERATOR RNG RANGE <br /> ,�-}, DUPLEX RECEPTACLE - UNIVERSAL SERIAL BUS I- F� BELL BL BLEACHERS GFCI GROUND FAULT CIRCUIT INTERRUPTER RSD ROLLING STEEL DOOR N G I PI E E R S <br /> � EXIT SIGN, WALL MOUNT �C USB BLDG BUILDING GSV GAS SOLENOID VALVE SDMPR SMOKE DAMPER <br /> REFER TO ARCHITECTURAL LIFE SAFETY �SPD DUPLEX RECEPTACLE - SURGE PROTECTED OS SMOKE DETECTOR C CONDUIT HH HAND HOLE SF SUPPLY FAN <br /> 1601 Fifth Avenue,Suite 900�Seattle,WA 98101 <br /> PLAN FOR DIRECTION OF TRAVEL ph 206.623.0777�fax 206.624.3775 <br /> CAB CABINET HID HIGH INTENSITY DISCHARGE SOLV SOLENOID VALVE coftman.com <br /> � SURFACE MOUNT EMERGENCY LUMINAIRE � DUPLEX RECEPTACLE - COMPUTERS SO-----� DUCT TYPE SMOKE DETECTOR {SUPPLY DUCT U.O.N.) CB CIRCUIT BREAKER HP HORSEPOWER SPD SURGE PROTECTIVE DEVICE LASTING crealivdy�results�relations�ips <br /> � DOUBLE DUPLEX RECEPTACLE OH FIXED TEMPERATURE HEAT DETECTOR CCN CLOSED CIRCUIT TELEVISION HPF HIGH POWER FACTOR SPEC SPECIFICATION <br /> , �] SURFACE MOUNT EMERGENCY/EXIT LUMINAIRE CKT CIRCUIT HPS HIGH PRESSURE SODIUM SPST SINGLE POLE, SINGLE THROW <br /> �- DOUBLE DUPLEX RECEPTACLE - COMPUTERS Q ADDRESSABLE RELAY CLG CEIUNG HT HEAT TRACE ST SHUNT TRIP <br /> O ❑ RECESSED DOWNLIGHT CM COFFEE MAKER IH INSTAHOT STD STANDARD <br /> � DUPLEX RECEPTACLE - CEILING MOUNTED Q MONITOR MODU�E CMU CONCRETE MASONRY UNIT IM ICE MACHINE STL STEEL <br /> � � RECESSED WALL WASH LUMINAIRE � CO CONDUIT ONLY IWD INTERCOM WALL DISPLAY SW SWITCH <br /> DOUBLE DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS I-{�H CONNECTION TO ELECTROMAGNETIC DOOR HOLDER <br /> � � RECESSED ADJUSTABLE LUMINAIRE COMM COMMUNICATION J-BOX JUNCTION BOX SWBD SWITCHBOARD <br /> � DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS Q CONNECTION TO ELECTROMAGNETIC DOOR HOLDER (MOUNT IN HEAD OF DOOR) COP COPIER kcmil THOUSAND CIRCULAR MILS SWGR SWITCHGEAR <br /> CT COOK TOP kV KILOVOLT TEL TELEPHONE <br /> PENDANT MOUNT LUMINAIRE �� DOUBLE DUPLEX RECEPTACLE - MOUNT IN AV CABINET O� 'G' INDICATES DEVICE WITH GUARD CT CURRENT TRANSFORMER kVA KILOVOLT AMPERE TEMP TEMPORARY <br /> DUPLEX RECEPTACLE WIRED TO SWITCHED CIRCUIT CU COPPER kW KILOWATT TP TRAP PRIMER <br /> � SURFACE MOUNT LUMINAIRE � D� INFRARED BEAM SMOKE DETECTOR TRANSMITTER DCVA DOUBLE CHECK VALVE ASSEMBLY kWh KILOWATT HOUR TR TAMPER RESISTANT <br /> �' DOUBLE DUPLEX RECEPTACLE WIRED TO SWITCHED CIRCUIT D� INFRARED BEAM SMOKE DEfECTOR RECEIVER DET DETAIL MAX MAXIMUM TTB TELEPHONE TERMINAL BOARD <br /> �-O WALL MOUNT SCONCE �A� DIA DIAMETER MCC MOTOR CONTROL CENTER TYP TYPICAL <br /> ABOVE COUNTER DUPLEX RECEPTACLE WIRED TO SWITCHED CIRCUIT DISC DISCONNECT MFR MANUFACTURER UC UNDER COUNTER <br /> � PENDANT MOUNT LINEAR LUMINAIRE INTERCOMjCLOCK SYSTEM DSPL DISPOSAL MECH MECHANICAL UGND UNDERGROUND <br /> • • PENDANT MOUNT LINEAR LUMINAIRE � SPECIAL RECEPTACLE - IYPE AS INDICATED <br /> DN DOWN MH MANHOLE; METAL HALIDE UH UNIT HEATER <br /> C� CORD REEL OO CEILING MOUNTED SPEAKER DO DOOR OPERATOR MIN MINIMUM UL UNDERWRITERS LABORATORIES <br /> o RECESSED UNEAR LUMINAIRE SO VR CEILING MOUNTED SPEAKER - VANDAL RESISTANT DPST DOUBLE POLE, SINGLE THROW ML MAGNETIC LOCK UON UNLESS OTHERWISE NOTED <br /> � RECESSED LINEAR WALL WASH LUMINAIRE S DRY DRYER MLO MAIN LUGS ONLY UPS UNINTERRUPTIBLE POWER SUPPLY <br /> � WALL MOUNTED SPEAKER DW DtSHWASHER MTD MOUNTED USB UNIVERSAL SERIAL BUS <br /> RECESSED 2x4 LUMINAIRE E Q U I P M E NT S WP DWG DRAWING MTG MOUNTING V VOLT <br /> � � WALL MOUNTED EXTERIOR SPEAKER (VANDAL RESISTANT & WEATHERPROOF) EA EACH MW MICROWAVE VA VOLT AMPERE <br /> � RECESSED 1 x4 LUMINAIRE � PANE�BOARD 277/480V EF EXHAUST FAN NEC NATIONAL ELECTRICAL CODE VFD VARIABLE FREQUENCY DRIVE <br /> OO WP CEILING MOUNTED EXTERIOR SPEAKER (VANDAL RESISTANT & WEATHERPROOF) EH ELECTRIC HEATER NEUT NEUTRAL VM VENDING MACHINE <br /> � RECESSED 2x2 LUMINAIRE G PANELBOARD 120/208V OR 120/240V ,�p EHD ELECTRIC HAND DRYER NC NORMALLY CLOSED W WATT <br /> , �l7 ANALOG CLOCK (12" U.O.N.). 'G' INDICATES WIRE GUARD ELEC ELECTRIC NIC NOT IN CONTRACT W� WITH <br /> �O SURFACE MOUNT 2x4 LUMINAIRE � CABINET - TYPE AS INDICATED ON PLAN ELEV ELEVATOR NO NUMBER; NORMALLY OPEN WAC WASHINGTON ADMINISTRATIVE CODE <br /> hQ DIGITAL CLOCK/SPEAKER COMBINATION <br /> � SURFACE MOUNT 1 x4 LUMINAIRE � SWITCHBOARD EMT ELECTRICAL METALLIC TUBING NTS NOT TO SCALE WAS WASHER <br /> I-QB 10" DIAMETER EXTERIOR CLASS CHANGE BELL EPO EMERGENCY POWER OFF OD OVERHEAD (COIIING) DOOR W/D STACKED WASHER / DRYER <br /> � SURFACE MOUNT LUMINAIRE 0 TRANSFORMER - SIZE AND VOLTAGE AS INDICATED ON PLAN EQUIP EQUIPMENT OF/CI OWNER FURNISHED / CONTRACTOR INSTALLED WF WASH FOUNTAIN Z <br /> � INTERCOM CALL BUTTON EWC ELECTRIC WATER COOLER OF/01 OWNER FURNISHED / OWNER INSTALLED WM WASHING MACHINE O <br /> a SURFACE MOUNT 2x2 LUMINAIRE � HORSEPOWER RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION EWH ELECTRIC WATER HEATER PF POWER FACTOR W�� WITHOUT � <br /> I-� INTERCOM HANDSET EWS ELECTRIC WINDOW SHADE PH or � PHASE WON WON OOOR � <br /> d d d TRACK MOUNT ACCENT LUMINAIRE(S) � COMBINATION STARTER � <br /> HP RATED, 3-POLE, NEMA 1 MtNIMUM UNLESS NOTED EXIST D(ISTING PIV POST INDICATOR VALVE WP WEATHERPROOF; WATERPROOFING <br /> �--�--} TRACK MOUNT PENDANT LUMINAIRE(S) OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED AUDiO/VISUAL SYSTEM FA FlRE ALARM PNL PANEL XFMR TRANSFORMER � <br /> FAAP FlRE ALARM ANNUNCIATOR PANEL PROJ PROJECTOR Z IMPEDANCE O <br /> � -� UNDER-CABINET LUMINAIRE ❑� NON-FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD I-� SMART BOARD J <br /> � WALL MOUNT LINEAR LUMINAIRE [F]-� FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD. VP VIDEO PROJECTOR W <br /> PROVIDE FUSES PER EQUIPMENT NAMEPLATE. � <br /> �—� PENDANT MOUNT STRIP LUMINAIRE I-OV CAN OUTLET & AUDIO-VIDEO JACKS (AV CABINET) <br /> 0 EQUIPMENT CONNECTION <br /> F--o—� SURFACE MOUNT STRIP LUMINAIRE I A{� AUDIO-VIDEO JACKS (DESK) � <br /> EF-1 MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL W <br /> �� WALL MOUNT STRIP LUMINAIRE EQUIPMENT SCHEDULE. � <br /> TELECOMMUNICATIONS ~ � J <br /> CONTINUOUS LINEAR LUMINAIRE � FLUSH FLOOR BOX Z ~ <br /> � <br /> �-❑ POLE MOUNT LUMINAIRE - SINGLE HfAD Q X TELECOMMUNICATIONS OUTLET W J O <br /> X = QTY. OF GAT 6 JACKS � <br /> POLE MOUNT LUMINAIRE - DOUBLE HEAD E�ECTR�CA� R�SER _ DEVICE MOUNTING HEIGHTS DRAWING INDEX V V = <br /> �+-❑ � WIRELESS ACCESS POINT 1 CAT 6 JACK W Q � <br /> � � WALL MOUNT POLE HEAD LUMINAIRE 1. GROUND SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL SHEET NUMBER DESCRIPTION � 1 � � <br /> V <br /> SECURITY SYSTEM DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS <br /> � FLAG POLE LUMINAIRE NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF E0.01 COVER SHEET AND GENERAL INFORMATION � U ch <br /> 30A/3P CIRCUIT BREAKER Q� DOOR CONTACTS THE OUTLET UNLESS OTHERWISE NOTED. E0.02 GENERAL NOTES � _ � � <br /> C3E GROUND MOUNT PATH LUMINAIRE --�o— NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES E0.03 LUMINAIRE SCHEDULE O m �I °O <br /> � AUDIO DEfECTOR RECEPTACI.ES !18 INCHES VERITCALLY MOUNTED E0.04 MECHANICAI EQUIPMENT SCHEDULE � <br /> C3EI IN-GROUND LUMINAIRE V� � � Z <br /> PNL UGHT SWITCHES '48 INCHES VERTICALLY MOUNTED E0.05 NREC O <br /> PANELBOARD I-QK KEYPAD W � a � <br /> o IN-GROUND LINEAR LUMINAIRE <br /> I-OC CARD READER TELEPHONE OUTLET - DESK 18 INCHES VERTICALLY MOUNTED E1.01 ELECTRICAI DEMOLITION PLAN � � W Z <br /> e STEPLIGHT � � _ <br /> O 360' MOTION SENSOR TELEPHONE OUTLET - WALL ;54 INCHES VERTICALLY MOUNTED E2.01 PARTIAL FIRST FLOOR LIGHTING PLANS W ~ �"� W Q <br /> �abc SINGLE POLE SWITCH - SUBSCRIPT � C U R R E N T T R A N S F O R M E R (C T) � Z W Q � <br /> INDICATES SWITCHING DUlY. PROVIDE ONE <br /> � SWITCH FOR EACH SWITCHING DUTY SHOWN. CABLE TE�EVISION (CAN) SYSTEM COMPUTER OUTLET - DESK '18 INCHES VERTICALLY MOUNTED E3.01 PARTIAL FIRST FLOOR POWER & SYSTEMS PLANS Q W W � � � <br /> �2 DOUBLE POLE SWITCH � C A B L E T O B U S C O N N E C T I O N z � v W � � <br /> � CAN OUTLET <br /> FIRE AIARM PULL STATION 48 INCHES F-- <br /> E5.01 ONE-LINE DIAGRAM � � O � o W <br /> �3 THREE-WAY SWITCH P AUTOMATIC TRANSFER SWiTCH (ATS) KEYPAD/CARD READER ,48 INCHES ° � I'� W � W <br /> o/ o �L O S E D C I R C U I T T E L E V I S I O N (,C C N) S Y S T E M E6.01 PANEL SCHEDULES a <br /> �p DIMMER SWITCH FlRE ALARM HORN, STROBE OR 'NOT LESS THAN 80" OR GREATER THAN 96" TO THE BOTTOM PROJECT NO. <br /> �4 C C N C A M E R A H O R N/S T R O B E E 7.0 1 S P E C I F I C A T I O N 171651 <br /> �K KEY OPERATED SWITCH XXX FEEDER TYPE - REFER TO FEEDER SCHEDULE ON ONE-LINE <br /> ISSUE DATE <br /> �S SWITCH WITH OCCUPANCY SENSOR M� UTILITY METER 1. COORDINATE ROUGH-IN WITH ARCHITECTURAL ELEVATIONS. 1 / 16 / 2018 <br /> �p SWITCH WITH PILOT LIGHT PM POWER MONITOR 2. WHERE A CONFLICT EXISTS, THE ARCHITECTURAL ELEVATIONS GOVERN. CURRENT REVISION <br /> . �T SWITCH WITH TIMER �W WATTHOUR METER <br /> AL <br /> � NO. REVISION DESCRtPTION DATE <br /> ° I-/ ILLUMINATION CQNTROL STATION (ICS) - SEE 0 SURGE PROTECTIVE DEVICE (SPD) <br /> � SCHEDULE <br /> wQ <br /> °v OS OCCUPANCY SENSOR, IR, CEILING MOUNT <br /> 0 0 0� OCCUPANCY SENSOR, DUAL TECHNOLOGY, RACEWAYS <br /> �- � 360' CEIIING MOUNT <br /> � ° RACEWAY CONCEALED IN WALL OR CElLING, EXPOSED iN UNFINISHED AREAS <br /> u, .N F Q�S OCCUPANCY SENSOR, DUAL TECHNOLOGY, <br /> ��;� WALL MOUNT - --- RACEWAY CONCEALED BELOW FLOOR <br /> U � <br /> � � �C CONTACTOR ^^^^^^"- FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS <br /> a� <br /> � L BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. <br /> o �� � RELAY A-I,3,5 HASHMARKS SHOW QUANTITY OF CONDUCTORS WHEN MORE THAN THREE <br /> � Y �O DAYLIGHT SENSOR REQUIRED DOT INDICATES GROUND CONDUCTOR NEUTRAL CONDUCTOR <br /> o � SHOWN LARGER. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. <br /> Qo <br /> � <br /> � �3 --� RACEWAY TURNING UP <br /> � U <br /> E �o � RACEWAY TURNING DOWN <br /> LL <br /> �-w Q <br /> � a� --S CIRCUIT CONTINUATION <br /> �- � <br /> � o <br /> � � —LV— LOW VOLTAGE WIRING <br /> � <br /> �a o m JUNCTION BOX <br /> , �, <br /> � Q PB PULL BOX <br /> � <br /> � �L COVER SHEET AND <br /> 00 <br /> � <br /> L � <br /> _° � GENERAL <br /> °��� INFORMATION <br /> �� � <br /> � �, <br /> � � <br /> � � <br /> � �, <br /> � � <br /> � o <br /> � � <br /> � �. <br /> � � SCALE: NONE <br /> ' � � <br /> � _ <br /> m � <br /> � <br /> � U <br /> N � <br /> � '=' <br /> � UU ` <br /> � Q <br /> tn �' <br /> F u) � <br />