My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1304 80TH ST SW 2018 EVERETT SCHOOL DISTRICT Plans 2022-11-22
>
Address Records
>
80TH ST SW
>
1304
>
EVERETT SCHOOL DISTRICT
>
Plans
>
1304 80TH ST SW 2018 EVERETT SCHOOL DISTRICT Plans 2022-11-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 2:13:15 PM
Creation date
5/1/2019 9:40:01 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1304
Tenant Name
EVERETT SCHOOL DISTRICT
Permit
B1801-029
Year
2018
Notes
CONVERT PORTION OF 1ST FL INTO STORAGE DISTRIBUTION CENTER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br /> � <br /> � S�R Ar�h ite�ts <br /> M <br /> W <br /> N <br /> � <br /> � 1402 3rd Ave Suite 730 <br /> � Seattle, WA 98101 <br /> . � GENERAL NOTES <br /> U <br /> O <br /> � 1. INFORMATION PRESENTED IN THIS SCHEDULE IS BASED ON EQUIPMENT SELECTED BY <br /> J THE MECHANICAL ENGINEER DURING THE DESIGN PROCESS (PRE-BID). THE ACTUAL � <br /> Z EQUIPMENT SELECTED BY MECHANICAL CONTRACTOR MAY BE DIFFERENT. PRIOR TO oF As <br /> � ROUGH-IN, OR ORDERING EQUIPMENT, COORDINATE WITH THE MECHANICAL CONTRACTOR �� _ � � <br /> � TO ESTABLISH THE ACTUAL LOAD AND OVERCURRENT PROTECTION REQUIREMENTS OF � � �, <br /> EACH PIECE OF EQUIPMENT. <br /> 90 <br /> 2. ALL DISCONNECTS AND STARTERS ARE FUSED, UNLESS OTHERWISE NOTED. '0 51 8 �' <br /> �'�.t� I��,GI Eg�O �v <br /> � <br /> 3. ALL DISCONNECTS ARE 3-POLE UNLESS OTHERWISE NOTED. �SSI AL ��1 <br /> 1/16/2018 <br /> � 4. DISCONNECT SWITCHES LOCATED OUTSIDE SHALL BE NEMA 3R. REFER TO MECHANICAL <br /> PLANS. DRAWN BY <br /> 5. LOCATE ALL DISCONNECTING MEANS PER NEC 430-1026 AND AHJ REQUIREMENTS. CEI <br /> CHECKED BY <br /> 6. FUSES SIZES SHOWN ARE APPROXIMATE. PROVIDE FUSES PER EQUIPMENT JLM <br /> MANUFACTURER'S REQUIREMENTS. APPROVE� BY <br /> 7. VARIABLE FREQUENCY DRIVES ARE PROVIDED BY MECHANICAL AND INSTALLED BY PW� <br /> ELECTRICAL, U.O.N. <br /> MECHANICAL EQUIPMENT CONNECTION SCHEDULE 8. ABBREVIATIONS C�FFMAN <br /> HRS: HORSEPOWER RATED MOTOR DISCONNECT WITH OVERLOAD PROTECTION N G I N E E R S <br /> � DUCT FAN / HEATER SCHEDULE AS: AMPERE SWITCH <br /> AF: AMPERE FUSE 1601 Fifth Avenue,Suite 900�Seattie,WA 98101 <br /> i ph 206.623.0717(fax 206.624.3775 <br /> EQU1P. NO. I DESCRIPTiON � LOCATION i HP KW FLA MCA � MOCF � VOLTAGE PHASE �DISCONNEC�'j STARTER FEEDER CIRCUITiNG NO i Ej J. WHERE NO STARTER IS USTED STARTER TO BE PROVIDED BY MECHANICAL. coffman.com <br /> LASTWG creativity�resutts�relationships <br /> DF-1 DUCT FAN STORAGE 142 1/2 120 1 HRS 1/2" - 2#12 & 1#12G 1L9-20 <br /> DH-1 DUCT HEATER BULK STORAGE 142 13 208 3 60AS/40AF 1" - 3#6 & 1#10G DP 2L2-25,27,29 <br /> DH-2 DUCT HEATER CRITTER ROOM 151 5 208 3 30AS/15AF 1/2" - 3#12 & 1#12G DP 2L2-32,34,36 <br /> � HEAT RECOVERY VENTILATOR <br /> EQUIP. NO. I DESCRIPTION LOCATION � HP ' kW i FLA MCA MOCP � VOLTAGE � PHASE `DISCONNECT � STAR�'ER FEEDER �� CIRCUITING NOTES <br /> HRV-1 HEAT RECOVERY VENTILATOR BULK STORAGE 142 0.324 120 1 HRS 1/2" - 2#12 & 1#12G 1L9-22 <br /> WATER HEATER SCHEDULE <br /> � , <br /> EQUIP. NO. ��� DESCRIPTION I LOCATION HP ' KW ' FLA MCA MOCP i VOLTAGE PHASE ;DISCONNECT � STARTER FEEDER CIRCUITING NOTES <br /> . HWT-2 WATER HEATER CRITTER ROOM 151 13.5 208 3 60AS/40AF 1" - 3#6 & 1#10G OP 2L2-31,33,35 <br /> SCHEDULE NOTES: <br /> 1. INDOOR UNIT SERVED VIA OUTDOOR UNIT <br /> GENERAL NOTES <br /> A. INFORMATION PRESENTED IN THIS SCHEDULE IS BASED ON EQUiPMENT SELECTED BY THE MECHANICAL ENGINEER DURING THE DESIGN PROCESS <br /> (PRE-BID). THE ACTUAL EQUIPMENT SELEGTED BY MECHANICAL CONTRACTOR UNDER THIS CONTRACT MAY BE DIFFERENT. COORDINATE WITH MECHANICAL <br /> EQUIPMENT SUBMITTALS FOR ACTUAL LOADS AND PROVIDE OVERCURRENT PROTECTIVE DEVICES AND CIRCUIT SIZES AS REQUIRED BY THE EQUIPMENT Z <br /> MANUFACTURER PRIOR TO ORDERING MATERIALS OR ROUGH-IN. O <br /> � g. ALL DISCONNECTS ARE FUSED, U.O.N. CONFIRM FUSE SIZE WITH EQUIPMENT MANUFACTURER. � <br /> C. LOCATE ALL DISCONNECTING MEANS PER 2014 NEC 430.102(6) AND AHJ REQUIREMENTS. Q <br /> V <br /> D. ABBREVIATIONS: O <br /> AS: AMPERE SWITCH <br /> HRS: HORSEPOWER RATED MOTOR DISCONNECT WITH OVERLOAD PROTECTION. J <br /> W <br /> E. VFD PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR. � <br /> � <br /> W � � <br /> , ~ � J <br /> Z � O <br /> W ' o <br /> � � _ <br /> W Q V <br /> V � � <br /> � � C� o <br /> � � � N <br /> O m —� � <br /> (/� J m z <br /> , W Q a o <br /> � � <br /> � „� z <br /> W F— � W Q <br /> VWW 'a � <br /> QWC� � o � <br /> Z — W � W <br /> W V � � ow <br /> ° V� 1'� LJJ � w <br /> a <br /> PROJECT NO. <br /> � 171651 <br /> ISSUE DATE <br /> 1 / 16 / 2018 <br /> CURRENT REVISION <br /> PERMIT SUBMITTAL <br /> ui NO. REVISION DESCRIPTION DATE <br /> U <br /> � <br /> L <br /> � <br /> O Q <br /> T� <br /> N (n <br /> Q� <br /> , � O <br /> Q C <br /> � O <br /> � � <br /> f6 <br /> .� '� <br /> N L <br /> U � <br /> .� N <br /> N � <br /> N <br /> _ � <br /> � L <br /> � � <br /> � � <br /> ' � L <br /> � � <br /> w <br /> � � <br /> Q O <br /> � <br /> 4--� <br /> � ? <br /> � 7 <br /> C V <br /> � <br /> � � O <br /> � L <br /> ++ fl. <br /> � L <br /> � � <br /> •C �� <br /> � � <br /> � � <br /> � � <br /> _ L <br /> � � <br /> � � <br /> � � <br /> Q� � <br /> `� �L MECHANICAL <br /> 00 <br /> °� EQUIPMENT <br /> ._ � <br /> ��= SCHEDULE <br /> . .N � <br /> � �, <br /> � N <br /> � � <br /> � �, <br /> � � <br /> � o <br /> � � <br /> � � <br /> :� o <br /> � .� <br /> -� � <br /> � _ <br /> � � <br /> � � <br /> � U <br /> � •� <br /> O `� <br /> '� Q <br /> � � <br /> , � � � <br />
The URL can be used to link to this page
Your browser does not support the video tag.