Laserfiche WebLink
�� _ _ _ . _ . <br /> N <br /> � <br /> � �.rC�l I���"�� . <br /> W . <br /> N <br /> � 1402 3rd Ave Suite 730 <br /> � Seattle, WA 98101 <br /> � <br /> � � I � � � � � <br /> , ¢ �l <br /> Z EXAMP�E DESIGNATION: PNL 2H1X � oF as ', <br /> � d �� � � <br /> � PANEL TYPE I p �. X = Sl"ANI�BY GENERATOR 1. SHEET INCLUDED FOR REFERENCE ONLY. .� <br /> 0 <br /> PNL PANEL E-- SUFFIX � � � <br /> DP = DIST'N PANEL 1 = flRST IN SEQUENCE ,o <br /> BUILDING FLOOR VOLTAGE � 51 8 � <br /> 1 = FIRST FLOOR � �' <br /> 2 = SECOND FLOOR H = 277Y,480V , °� ��'Gt��g� w <br /> L = 120Y 208V OR 120 240V �sst �� <br /> 1/16/2018 <br /> DRAWN BY <br /> . C�� <br /> F�ED�R �V����L� CHECKED BY <br /> s��ba �g���� J L M <br /> APPROVED BY <br /> 50 1" - 4#6, 1#10 G <br /> 50N 1" -- 3#6, 1#10 G �w� . <br /> 100 1-1/2" - 4�2, 1#8 G <br /> 100N 1-1/4" - 3�2, 1�8 G <br /> 150 2" - 4�1/0, 1#6 G <br /> 150N 1-1/2� — 3#�/0, ��s c N G I N E E R S <br /> 175N 1-1�2„ — 3#2��, 1#6 G 1601 Fifth Avenue,Suite 900�Seattle,WA 98101 <br /> 225 2-1/2" - 4#4/0, 1#4 G <br /> ph 206.623.0717�fax 206.624.3775 <br /> ' 400 3-1�2" - 4-600 kCmil, 1#2 G I cottman.com <br /> LASTW G creativity�resWts�relationships <br /> 600SL 2 3" - 4�350 kcmii <br /> NOTES: <br /> 1. ALL FEEDERS ARE COPPER WITH THHN/THWN INSULATION. <br /> 2. F�EDERS WITH NO LETTER SUFFIX AFiER THE NUMBER ARE 3PH, 4W WITH A GROUND CONDUCTOR. � • <br /> 3. SYMBOL NUMBER INDICATES FEEDER RAl1NG. <br /> 4. FEEDER SYM60LS WITN LET(ER SUFFIX AFfER THE NUMBER ARE AS FOLLOWS <br /> N: N� NEUTf�AL <br /> D: DOUBLE OF2 OVER5IZED NEUTRAL <br /> SL: SERVICE LA7ERAL <br /> V: FEEDER SIZE INCREASED FOR VOLTAGE DROP <br /> • 5. A�BR�VIATIONS ARE AS FOLLOWS: <br /> N: NEUTRAL <br /> G: GROUND <br /> � <br /> INTEROR ' EXTERIOR <br /> � <br /> � <br /> 175N <br /> � <br /> DP DP DP DP <br /> 2H1 2L2 2L3 XFMR 214 2L4 , <br /> XFMR 212 1125 KVA-3� <br /> 112.5 KVA-3� 480V: 120/240V <br /> �- - - � �- - - �I <br /> � � � 400 � ? � <br /> 1"C., 3�4 & 1�10 G z � � o � � � o <br /> SECOND FLOOR � �- — — � � � � — — ��� � � <br /> _ _ � <br /> 2�� � <br /> FLEVATOR - 2�5 225 100 100 <br /> 480V-3�b-20riP F � � <br /> PNL PNL PNL PNL PNL � ' <br /> 1L6 1L7 1L8 1L9 1L10 � N <br /> � <br /> rn <br /> � � <br /> � � <br /> O <br /> � <br /> 6 6 6 c� <br /> %z"-2#14 � Z <br /> � � � <br /> I� <br /> d <br /> FIRST FLOOR Q � <br /> � � ~ <br /> z � � W <br /> � � � <br /> o � � > <br /> � �- W <br /> a <br /> PROJECT NO. <br /> 171651 <br /> � ISSUE DATE <br /> ?ao 200 1 / 16 / 201 � <br /> _ — 200A-4P CONTACTOR WITH CURRENT REVISION <br /> PNI PNI_ PNL PNL PNL EXT 120V COIc. MOUNT IN N_MA <br /> 1 ENCLO�URE ABOVE PaNFI PERIVIIT SUBMITTAL <br /> � REMOTE ANNUf�1CIATOR IN DISPATCH 1 H2X 1 I 3X 1�4' 1 L5 1 H1 �TG I PNL PNL PNL (TYP OF 2) NO. REVISION DESCRIPTION DATE <br /> v XFMR 1 L3X X�MR 1 L4 CON T. 1 L11 1 I 11 1 I 12 <br /> � 30 KVA-3� 75 KVA-3 Q 1 PNL X F M R 1 1 1 1 ' <br /> � � � � I 112.5KVA-3Q' <br /> ° � ( � � 1 0 0 � � 2 2 5 r - - -� <br /> a� <br /> � � 400 <br /> a�i v� <br /> %a" WITH WIRING PER MFG REQUIREMENTS �, , �, <br /> 0 0 o L - - J �8 �- - - J �2 ��„ � <br /> a� .o = = I �� � ! — — � �1/� <br /> � N 100 — _ <br /> . .� �L . . . . _ _ . <br /> Q I <br /> NEC ARTICI F 702 STANDBY <br /> " � 40d 100N 175N <br /> '� co OPTIONAL STANCBY GENERATOR EXIT SIGNS ATS <br /> � � & EGRESS LIGHTS TO BE PROVID�D �hJiTH 3-P01 F W�;N P ° I <br /> � L BATTERY PACKS. 100A 100 225 <br /> o � <br /> . 100 <br /> � � 480Y/277V-3PH, 4W �i�4„ — — — — — — � . . <br /> o � 50KW/62.5KVA <br /> �}�°, GENERATOR � � <br /> o '� M I � I <br /> F •� Gn J � <br /> � ° SERVICE POINT �i' �' <br /> � � Q CT ENCI OSURE� � �- � � � � � <br /> � �, E X I S TI N G � 0 100 �� ';� �? r? ,�, o � <br /> � � o PUD TRANSFORMER 100A-3P F 600S� o ` o \ o ` N ` `� ` N <br /> � � 12.47 KV: 480Y/277V � � � �„ � �, <br /> .� � 100 _ g � � <br /> � � l � — # <br /> � � � 600A BUS <br /> � `� � � � <br /> � �- <br /> Q�o MAIN ELECTRICAL ROOM � � N ` _ � I FUELING STATION ���--LINE DIA��AI� <br /> � �„ <br /> ao <br /> I I 23,aoo asYM MAIN SERVICE PANE� (MSP� <br /> .� � <br /> � <br /> I I 277/480V-3�-4W <br /> �.� <br /> .� � <br /> � � �- — — — — — -� <br /> � � <br /> � � � 12.47 KV TO POLE �---BOND TO BUILDING <br /> � <br /> � o - WATER, FIRE AND GAS <br /> � o MAIN PIPING. <br /> � � SCALE: NONE <br /> � � <br /> � _ <br /> � � <br /> .� � . <br /> C U <br /> N � <br /> � ••= <br /> � s <br /> U � <br /> O Q <br /> � <br /> N � <br /> I-- (n � <br />