1111 80TH ST SW 2017 JAMCO Plans 2022-11-21
>
Address Records
>
80TH ST SW
>
1111
>
JAMCO
>
Plans
>
1111 80TH ST SW 2017 JAMCO Plans 2022-11-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 3:52:58 PM
Creation date
5/2/2019 8:57:52 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1111
Tenant Name
JAMCO
Permit
B1709-040
Year
2017
Notes
ADD FREIGHT LIFT EXTEND MEZZANINE AND NEW STAIRS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> -� � 2x6 CAP-PAINT -- - � - <br /> UNDERSIDE OF i UNDERSIDE OF l <br /> !' <br /> STRUCTURE ABOVE ' I STRUCTURE ABOVE � <br /> 2x6 VERTICAL-PAINT ' `Wi <br /> � � � _ � <br /> � ��� : ' "� � . �=° " - <br /> i -- <br /> I � <br /> � � - <br /> 4x4 POST LAG TO FACE OF PAINTED MDF CAP ANQ TRIM � 11180th Street SW <br /> EXISTNG CONC� _ i ! WALL,SPACE @ 5'-0"O.C. � ` ` PAINT <br /> EXTERIOR WALLS '� <br /> MAXIMUM SPAN (TYP.) EVERETT, WA 98203 <br /> io <br /> M 5/8"GYP. BOARD 5/8"GYP. BOARD —_ __.. <br /> WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS <br /> cLD BATHROOM SIDE c'LD16"O.C. BEYOND, @ BATHROOM SIDE �16"O.C. BEYOND, <br /> ; SPAN BETWEEN STUD TRACKS _ SPAN BETWEEN STUD TRACKS • <br /> i SOUND ATTENUATION ;' AT FLOOR AND STRUCTURE ABOVE SOUND ATTENUATION ----- � AT FLOOR AND STRUCTURE ABOVE ��� �.• <br /> BRACE AS REQUIRED(TYP.) ; BRACE AS REQUIRED(TYP.) <br /> I INSULATION � INSULATION <br /> I o I � � 1725 westlake avenue n. <br /> � BATHROOM SIDE 1/2" 5/8"GWB ON ROOM SIDE 5/8"GWB ON ROOM SIDE suite 210 <br /> � :- <br /> j OR FULL HEIGHT TILES 3 5J8"CONTINUOUS METAL TRACK � 3 5/8"CONTWUOUS METAL TRACK seattle, washington 98109 <br /> SEE BATHROOM : FASTEN TO SLAB BELOW FASTEN TO SLAB BELOW <br /> I ELEVATIONS AND SCHEDULE � SEE STRUCTURAL SEE STRUCTURAL 206.838.5485 p <br /> i „ -�' <br /> � • 206.713.4076 m <br /> � , . <br /> --� ,• � x <br /> � I ' -'+' BASE REFER TO FINISH SCHEDULE � 206.464.0700 f <br /> � i `. � BASE REFER TO FINISH SCHEDULE <br /> � FINISH FLOOR CAULKING j '�� FINISH FLOOR CAULKWG -- FINISH FLOOR ksmith@smithco.org <br /> i (SEE SCHE�ULE) _� (SEE SCHEDULE) <br /> I , http://www.smithco.org/ <br /> 5/8" � 3 5/8" 5/8" <br /> � ' ACTUAL <br /> � � � NOMINAL <br /> - Consultant <br />'� � EXISTING DEMISING WALL NEW GUARRAILL NON-RATED PARTITION WALL � NON-RATED PARTITION WALL <br /> 1 6�� STUDS THIS WALL UNDER SEPARATE PERMITBYLANDIORD SCALE : N.T.S � 6�� STUDS SCALE : N.T.S 3 3-5/8�� METAL STUDS - EXISTING SCALE : N.T.S. 4� 3-5/8�� METAL STUDS SCALE : N.T.S. <br /> 6294 <br /> � � REGISTERED <br /> ARCHITECT <br /> ' UNDERSIDE OF �' <br /> � 2x1 O JOISTS @ 16"O.C. �. STRUCTURE ABOVE KaTM � sMina <br /> � STATE OF WASHINGTON <br /> FINISH CEILING <br />� I � (SEE SCHEDULE) <br /> � -- - - FINISH CEkLING EXISTING WALL <br /> i (SEE SCHEDULE) <br /> �- <br /> r <br /> 5/8"GYP. BOARD 5/8"GYP.BOARD <br /> FIRE RATED ON ROOM SIDE <br /> WATER RESIST.WALL BD. OF PARTITION SOUND ATTENUATION <br /> �BATHROOM SIDE INSULATION NOT USED Consultant Registration Architect Registration <br /> NOT USED <br /> � i j � ---- 5/8"GYP. BOARD <br /> : I 2X6 WOOD STUDS�16"O.C. WATER RESIST.WATER BD. <br /> SOUND ATTENUATION �BATHROOM SIDE <br /> INSULATION 1 1/2"FURRING CHANNEL <br /> 2 1/2"OR 3 5/8"METAL STUDS <br /> ' �16"O.C. <br /> BATHROOM SIDE <br />� HALF OR FULL HEIGHT TILES <br /> '� 2X6 WOOD S�LL PLATE CONT. SEE BATHROOM ELEVATIONS . <br /> . <br /> H <br /> CONTINUOUS METAL TRACK <br /> � ', FASTEN TO SLAB BELOW <br /> ' i WITH 1/2"STUD BOLTS <br /> BASE REFER TO FINISH SCHEDULE BASE REFER TO FINISH SCHEDULE <br /> � FINISH FLOOR FINISH FLOOR Issues and Revisions <br /> (SEE SCHEDULE) (SEE SCHEDULE) <br /> No. Date Issues By Check <br /> vaRiE ; 5is° 1 09.25.17 PERMIT KLS <br /> 7� LEAD LINED PARTITION 1 1/2" METAL 2 10.04.17 OWNERS REVISION K�S <br />� / CHANNEL SCALE : N.T.S. 3 11.27.17 OWNERS REVISIONS KLS <br /> 4 12.12.17 CONSTRUCTION SET KLS <br /> PLUMBING PARTITION LEAD LINED PARTITIONS 3 5/8" METAL LEAD LINED 2HR RATED WALL FIRE TEST NO.: UL Des U419 <br /> 5 6" METAL STUDS SCALE : N.T.S. 6 FURRING WALL 1 1/2" METAL CHANNEL SCALE : N.T.S. 7A STUDS SCALE : N.T.S. 8 3 5/8" METAL STUDS SCALE : N.T.S <br /> 6A FURRING WALL 3 5/8" METAL STUDS SCALE : N.T.S. TOPOFSTUDAT14�-s�� <br /> / <br /> \ / <br /> 66 FURRING WALL 6" METAL STUDS SCALE : N.T.S. � - LATERALBRACING-SEE <br /> ,, <br /> STRUCTURAL DRAWINGS <br />� - <br /> --- SOUND BATTS <br /> 5/8"GYP BOARD � ` FINISH CEILING <br /> '• r (SEE SCHEDULE) <br /> SOUND ATTENUATION INSULATION � <br /> WD BLOCKING N OT U S E D 518"GYP. BOARD — ; <br /> AS REQUIRED WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS <br /> NOT USED �BATHROOM SIDE �16"O.C. BEYOND, <br /> � SPAN BETUVEEN STUD TRACKS Pro ect Name JAMCO America �t1C. <br /> i � AT FLOOR AND STRUCTURE ABOVE � <br />� � — SOUND ATTENUATION — BRACE AS REQUIRED <br /> (TYF.) <br /> � ��� ��� �� METAL STUDS INSULATION . PCO eCt NUf11b2f 02016063.01 <br /> � ° -- 5/8"GWB ON ROOM SIDE � � <br /> � 6"CONTINUOUS METAL TRACK Description WALL TYPES <br /> I <br /> - 3/4"PLYWOOD , _ FASTEN TO SLAB BELOW <br /> r SEE STRUCTURAL DRAWINGS <br /> BETWEEN METAL STUDS � C011l uter File A-101.DWG <br /> RUNNING FROM � p <br /> 4'-6"AFF.�7'-0"AFF v '' -�-- BASE REFER TO FINISH SCHEDULE <br /> CAULKING - <br /> FINISH FLOOR Scale AS NOTED <br /> (SEE SCHEDULE) <br /> Template '.� `^ 20' �!1� <br />� All ideas, designs, arrangements, and plans indicated or <br /> represented by this drawing are owned by and the property of <br /> smith co. Ilc and were created, evolved, and developed <br /> NON-RATED NON-RATED PARTITION WALL NON-RATED PARTITION WALL for use on and in connection with the specified project. None of <br /> 9 PLUMBING CHASE SCALE : N.T.S. FIRE TEST NO.: U419 � � PARTITION W/BLOCKING PLAN DETAIL � � 3-5/8 METAL STUDS C.H.= 14 -6 A.F.F. �2 such ideas, designs, arrangements or p�ans sha�l be used <br /> SCALE : 1 1/2" = 1'-0" " � > � �� � SCALE : N.T.S. 3-5/8�� METAL STUDS SCALE : N.T.S. by or disclosed to any person, firm, or corporation for any <br /> purpose whatsoever withaut the written permission of smith co. Ilc. <br /> � <br />, <br />