Laserfiche WebLink
. <br /> -� � 2x6 CAP-PAINT -- - � - <br /> UNDERSIDE OF i UNDERSIDE OF l <br /> !' <br /> STRUCTURE ABOVE ' I STRUCTURE ABOVE � <br /> 2x6 VERTICAL-PAINT ' `Wi <br /> � � � _ � <br /> � ��� : ' "� � . �=° " - <br /> i -- <br /> I � <br /> � � - <br /> 4x4 POST LAG TO FACE OF PAINTED MDF CAP ANQ TRIM � 11180th Street SW <br /> EXISTNG CONC� _ i ! WALL,SPACE @ 5'-0"O.C. � ` ` PAINT <br /> EXTERIOR WALLS '� <br /> MAXIMUM SPAN (TYP.) EVERETT, WA 98203 <br /> io <br /> M 5/8"GYP. BOARD 5/8"GYP. BOARD —_ __.. <br /> WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS <br /> cLD BATHROOM SIDE c'LD16"O.C. BEYOND, @ BATHROOM SIDE �16"O.C. BEYOND, <br /> ; SPAN BETWEEN STUD TRACKS _ SPAN BETWEEN STUD TRACKS • <br /> i SOUND ATTENUATION ;' AT FLOOR AND STRUCTURE ABOVE SOUND ATTENUATION ----- � AT FLOOR AND STRUCTURE ABOVE ��� �.• <br /> BRACE AS REQUIRED(TYP.) ; BRACE AS REQUIRED(TYP.) <br /> I INSULATION � INSULATION <br /> I o I � � 1725 westlake avenue n. <br /> � BATHROOM SIDE 1/2" 5/8"GWB ON ROOM SIDE 5/8"GWB ON ROOM SIDE suite 210 <br /> � :- <br /> j OR FULL HEIGHT TILES 3 5J8"CONTINUOUS METAL TRACK � 3 5/8"CONTWUOUS METAL TRACK seattle, washington 98109 <br /> SEE BATHROOM : FASTEN TO SLAB BELOW FASTEN TO SLAB BELOW <br /> I ELEVATIONS AND SCHEDULE � SEE STRUCTURAL SEE STRUCTURAL 206.838.5485 p <br /> i „ -�' <br /> � • 206.713.4076 m <br /> � , . <br /> --� ,• � x <br /> � I ' -'+' BASE REFER TO FINISH SCHEDULE � 206.464.0700 f <br /> � i `. � BASE REFER TO FINISH SCHEDULE <br /> � FINISH FLOOR CAULKING j '�� FINISH FLOOR CAULKWG -- FINISH FLOOR ksmith@smithco.org <br /> i (SEE SCHE�ULE) _� (SEE SCHEDULE) <br /> I , http://www.smithco.org/ <br /> 5/8" � 3 5/8" 5/8" <br /> � ' ACTUAL <br /> � � � NOMINAL <br /> - Consultant <br />'� � EXISTING DEMISING WALL NEW GUARRAILL NON-RATED PARTITION WALL � NON-RATED PARTITION WALL <br /> 1 6�� STUDS THIS WALL UNDER SEPARATE PERMITBYLANDIORD SCALE : N.T.S � 6�� STUDS SCALE : N.T.S 3 3-5/8�� METAL STUDS - EXISTING SCALE : N.T.S. 4� 3-5/8�� METAL STUDS SCALE : N.T.S. <br /> 6294 <br /> � � REGISTERED <br /> ARCHITECT <br /> ' UNDERSIDE OF �' <br /> � 2x1 O JOISTS @ 16"O.C. �. STRUCTURE ABOVE KaTM � sMina <br /> � STATE OF WASHINGTON <br /> FINISH CEILING <br />� I � (SEE SCHEDULE) <br /> � -- - - FINISH CEkLING EXISTING WALL <br /> i (SEE SCHEDULE) <br /> �- <br /> r <br /> 5/8"GYP. BOARD 5/8"GYP.BOARD <br /> FIRE RATED ON ROOM SIDE <br /> WATER RESIST.WALL BD. OF PARTITION SOUND ATTENUATION <br /> �BATHROOM SIDE INSULATION NOT USED Consultant Registration Architect Registration <br /> NOT USED <br /> � i j � ---- 5/8"GYP. BOARD <br /> : I 2X6 WOOD STUDS�16"O.C. WATER RESIST.WATER BD. <br /> SOUND ATTENUATION �BATHROOM SIDE <br /> INSULATION 1 1/2"FURRING CHANNEL <br /> 2 1/2"OR 3 5/8"METAL STUDS <br /> ' �16"O.C. <br /> BATHROOM SIDE <br />� HALF OR FULL HEIGHT TILES <br /> '� 2X6 WOOD S�LL PLATE CONT. SEE BATHROOM ELEVATIONS . <br /> . <br /> H <br /> CONTINUOUS METAL TRACK <br /> � ', FASTEN TO SLAB BELOW <br /> ' i WITH 1/2"STUD BOLTS <br /> BASE REFER TO FINISH SCHEDULE BASE REFER TO FINISH SCHEDULE <br /> � FINISH FLOOR FINISH FLOOR Issues and Revisions <br /> (SEE SCHEDULE) (SEE SCHEDULE) <br /> No. Date Issues By Check <br /> vaRiE ; 5is° 1 09.25.17 PERMIT KLS <br /> 7� LEAD LINED PARTITION 1 1/2" METAL 2 10.04.17 OWNERS REVISION K�S <br />� / CHANNEL SCALE : N.T.S. 3 11.27.17 OWNERS REVISIONS KLS <br /> 4 12.12.17 CONSTRUCTION SET KLS <br /> PLUMBING PARTITION LEAD LINED PARTITIONS 3 5/8" METAL LEAD LINED 2HR RATED WALL FIRE TEST NO.: UL Des U419 <br /> 5 6" METAL STUDS SCALE : N.T.S. 6 FURRING WALL 1 1/2" METAL CHANNEL SCALE : N.T.S. 7A STUDS SCALE : N.T.S. 8 3 5/8" METAL STUDS SCALE : N.T.S <br /> 6A FURRING WALL 3 5/8" METAL STUDS SCALE : N.T.S. TOPOFSTUDAT14�-s�� <br /> / <br /> \ / <br /> 66 FURRING WALL 6" METAL STUDS SCALE : N.T.S. � - LATERALBRACING-SEE <br /> ,, <br /> STRUCTURAL DRAWINGS <br />� - <br /> --- SOUND BATTS <br /> 5/8"GYP BOARD � ` FINISH CEILING <br /> '• r (SEE SCHEDULE) <br /> SOUND ATTENUATION INSULATION � <br /> WD BLOCKING N OT U S E D 518"GYP. BOARD — ; <br /> AS REQUIRED WATER RESIST.WALL BD. 3 5/8"20 GA. METAL STUDS <br /> NOT USED �BATHROOM SIDE �16"O.C. BEYOND, <br /> � SPAN BETUVEEN STUD TRACKS Pro ect Name JAMCO America �t1C. <br /> i � AT FLOOR AND STRUCTURE ABOVE � <br />� � — SOUND ATTENUATION — BRACE AS REQUIRED <br /> (TYF.) <br /> � ��� ��� �� METAL STUDS INSULATION . PCO eCt NUf11b2f 02016063.01 <br /> � ° -- 5/8"GWB ON ROOM SIDE � � <br /> � 6"CONTINUOUS METAL TRACK Description WALL TYPES <br /> I <br /> - 3/4"PLYWOOD , _ FASTEN TO SLAB BELOW <br /> r SEE STRUCTURAL DRAWINGS <br /> BETWEEN METAL STUDS � C011l uter File A-101.DWG <br /> RUNNING FROM � p <br /> 4'-6"AFF.�7'-0"AFF v '' -�-- BASE REFER TO FINISH SCHEDULE <br /> CAULKING - <br /> FINISH FLOOR Scale AS NOTED <br /> (SEE SCHEDULE) <br /> Template '.� `^ 20' �!1� <br />� All ideas, designs, arrangements, and plans indicated or <br /> represented by this drawing are owned by and the property of <br /> smith co. Ilc and were created, evolved, and developed <br /> NON-RATED NON-RATED PARTITION WALL NON-RATED PARTITION WALL for use on and in connection with the specified project. None of <br /> 9 PLUMBING CHASE SCALE : N.T.S. FIRE TEST NO.: U419 � � PARTITION W/BLOCKING PLAN DETAIL � � 3-5/8 METAL STUDS C.H.= 14 -6 A.F.F. �2 such ideas, designs, arrangements or p�ans sha�l be used <br /> SCALE : 1 1/2" = 1'-0" " � > � �� � SCALE : N.T.S. 3-5/8�� METAL STUDS SCALE : N.T.S. by or disclosed to any person, firm, or corporation for any <br /> purpose whatsoever withaut the written permission of smith co. Ilc. <br /> � <br />, <br />