Laserfiche WebLink
. <br /> GENERAL WATERPROOFING DETAILS AND NOTES WATERPROOFINGAND BUILDING ENVELOPE PRODUCT SELECTIONS <br /> FOR WALL WITH CONTINUOUS INSULATION <br /> 1. WEATHER RESISTIVE BARRIER (WRB) TYVEK HOMEWRAP BY DUPONT 11. UNDERSLAB VAPOR RETARDER a. FORTIFIBER MOISTOP ULTRA 10 (TAPED AT SEAMS AND FASTENING NOTES: FOR INSTALLING HARDIEPANEL CLADDING AT THE FOLLOWING <br /> FLASHING NOTES: PENETRATIONS) CONDITIONS: <br /> SEE ICGES REPORT ESR-1844 AND <br /> 1. FOLLOW ALL INSTALLATION REQUIREMENTS SET FORTH BY THE MANUFACTURER{S)OF ALL FLASHING 2. UV-RESISTANT WRB REVEAL SHIELD BY VAPROSHIELD b. STEGO WRAP 10 mil (TAPED AT SEAMS AND PENETRATIONS) J.H. TECHNICAL BULLETIN#19 - WIND ZONE B, MAX. WIND SPEED 110MPH <br /> FOR ADDITIONAL INFORMATION. - ATTACHING CLADDING THROUGH 3/S" BATTENS TO 7l16" OSB <br /> PRODUCTS USED ON THIS PROJECT. THESE DRAWINGSARE INTENDED TO ASSIST THE CONTRACTOR SHEATHING. <br /> WITH THE EXECUTION OF A HIGH-QUALITY WINDOW/DOOR INSTALLATION. THESE DETAILS DO NOT 3. SELF ADHERED MEMBRANES (SAM) SAM: STRAIGHTFLASH BY DUPONT(STANDARD WALL SAM, USE U.N.O.) 12. DAMP-PROOFING GRAYWALL DAMP-PROOFING BY RUBBER POLYMER CORPORATION <br /> OVERIDE ANY MANUFACTURER REQUfREMENTS OR INSTRLLATION TECHNIQUES. IF CONFLICTS OGGUR SAM-FS: FLEXWRAP BY DUPONT(FLEXIBLE SAM} 20 mil min. application NO. 8 X 1 5/8" LONG RIBBED WAFERHEAD FASTENERS, GALVANIZED <br /> BETWEEN THESE DRAWINGS AND ANY INSTALLATION TECHNIQUE OR REQUIREMENT, THE CONTRACTOR SAM-UV: REVEAL SHIELD SA FLASHING (UV-RESISTANT SAM) OR STAINLESS AS REQUIRED. <br /> MUST CONSULT IMMEDIATELY WITH THE PROJECT ARCHITECT FOR RESOLUTION. SAM-HT: GRACE ULTRA(BUTYL BASED HIGH-TEMP SAM) FASTENERS TO BE 6"AT EDGES, 12" FIELD. FASTENERS MUST BE <br /> SAM-AS: HENRY BLUESKIN SA(SBS RUB. ASPHALT SAM) 13. INTERIOR VAPOR RETARDER PVA INTERIOR LATEX PRIMER & SEALER BY SHERWIN WILLIAMS DRIVEN THROUGH NON-NAILABLE MATERIALS INTO OSB SHEATHING <br /> 2. SEE PROJECT SPECIFICATIONS FOR IDENTIFICATION OF EXACT PRODUCT SPECIFICATIONS. (Verify that this is NOT an interior class I vapor retarder) <br /> 4. WRB TAPE 3"TYVEK TAPE BY DUPONT FASTENERS TO BE MIN. 3/8" FROM PANEL EDGE, 2" FROM PANEL <br /> EDGES AT CORNERS. <br /> 3. CONTRACTOR TO VERIFY THAT THESE INSTALLATION TECHNIQUES TO DO CONFILICT WITH WINDOW/ 14. CLOSED-CELL SPRAY FOAM JM CORBOND ill BY JOHNS MANSVILLE <br /> DOOR MANUFACTUERER'S RECOMMENDATIONS. 5. LIQUID-APPLIED WATERPROOFING TYVEK FLUID APPLIEb WB BY DUPONT D A V I D <br /> FOR WALLS WITHOUT CONTINUOUS INSULATION <br /> 4. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD. MEMBRANE AND FLASHING COMPONENTS ARE FOR INSTALLING HARDIEPANEL CLADDING AT THE FOLLOWING V A N D E R V O R T <br /> NOT SHOWN TO SCALE FOR CLARITY. 5. VERTICAL RAINSCREEN BATTENS& a. BATTENS: 1/2"THICK PRESSURE TREATED PLYWOOD 15. BATT INSULATION JOHNS MANVILLE KRAFT-FACEb BATTS& ROLLS CONDITIONS: A R C H I T E C T S <br /> HORIZONTAL VENT STRIPS BATTENS, 2 1/2"WIDE. VENT STRIPS: COR-A-VENT SV-3 <br /> 5. SELF-ADHERED FLASHING PRODUCTS MAY NEED TO BE ROLLED TO ACTIVATEADHESIVE. SEE - WIND ZONE B, MAX. WIND SPEED 110MPH A I A <br /> MANUFACTURER'S RECOMMENDATIONS. b. BATTENS: 3/8"THICK DUPONT RAINVENT BATTENS. VENT STRIPS: - ATTACHING CLADDING THROUGH 3i8" BATTENS TO MIN 20 GAUGE <br /> DUPONT RAINVENT W/ INSECT SCREEN WRAPPED OVER. 16. SILL SEALER GREEN GUARD SILL SEALER BY KINGSPAN METAL STUDS <br /> 6. IF WEATHER RESISTIVE BARRIER (WRB} IS USED AS THE EXTERIOR AIR BARRIER, ALL LAPPED JOINTS OF <br /> THE WRB MUST BE COMPLETELY SEALED W/APPROVED SEALING TAPE OR ADHESIVE. FURTHEMORE,THE NO. 8 X 1 1/2" LONG HD RIBBED BUGLEHEAD SCREW, GALVANIZE <br /> OVERLAPPING EDGES OF THE WRB MUST BE SECURED TO THE SELF-ADHESIVE FLASHINGS W/APPROVED 6. VENT WEEPS AT MASONRY DRIWALL WEEP VENTS 025 BY KEENE OR STAINLESS AS REQUIRED. <br /> SEALANT. 17. SLOPED ROOFING SEE ELEVATIONS(IF PART OF PROJECT) FASTENING TO BE 6"AT EDGES, 12" FIELD. FASTENERS MUST BE 2 0 Q 0 <br /> DRIVEN THROUGH NON-NAILABLE MATERIALS INTO METAL STUDS. F A I R V I E W <br /> 7. FOR ALL WATERPROOFING/FLASHING ASSEMBLIES, CONTRACTOR TO REVIEW ENTIRE INSTALLATION 7. FASTENERS a. C�ADDING: STAINLESS STEEL(S.S.)FASTENERS. <br /> PROCEDURE WITH ARCHITECT PRIOR TO INSTALLATION. b. METAL FLASHINGS TO WALL: HOT-DIP GALVANIZEQ OR S.S. FASTENERS TO BE MIN. 3/8" FROM PANEL EDGE, 2" FROM PANEL A V E N U E E A S T <br /> 18. LOW-EXPANDING SPRAY FOAM WINDOW AND DOOR FOAM BY DUPONT EDGES AT CORNERS. <br /> 8. SPRAYADHESIVE (To bond WRB to WESTECH WT-MP13 MULTI-PURPOSE CLEAR SPRAYADHESIVE S U I T E 1 0 3 <br /> concrete or steel) <br /> S E A T T L <br /> DRAWING LEGEND 19. WALL PENETRATION FLASHING QUICKFLASH WEATHERPROOFING PRODUCTS: SPECIFY PER W A S H I N G T O N <br /> 9. SEALANTS SEALANT 1: DOW 758 SILICONE (Use with WRB for complete air barrier) PANELS PENETRATION TYPE. <br /> 9 8 1 0 2 <br /> ___ SEALANT 2: SONOLASTIG 150 (For interior or exterior general caulking) <br /> 206 • 784 • 1614 <br /> � INDICATES ELEMENT AT CURRENT INSTALLATION STEP <br /> � 20. PLASTIC SHIMS PLASTIG HORSESHOE SHIMS AVAILABLE FROM ATLAS SUPPLY <br /> , FAX 784 - 5401 <br /> �- " 10. EXPOSED LOW-SLOPE ROOFING a. LIQUID APPLIED: TUFFLEX(FULLY REINFORCED W/RBC 50 MILS W140 <br /> �; � INDICATES ELEMENT AT PREVIOUS INSTALLATION STEP(S} Mi�BASE AND 40 MIL TOPCOAT) <br /> � � b. SINGLE-PLY MEMBRANE: GAF TPO EVERGUARD 80 -80 MIL TPO, FULLY 21. WRB FASTENER TYVEK WRAP CAP NAILS BY DUPONT OR TYVEK WRAP CAP SCREWS <br /> ADHERED BY DUPONT <br /> /,r, INDICATES WEATHER RESISTIVE BARRIER c. LOW SLQPE METAL ROOF: MBCI ULTRA-DEK 2�4" PANELS W/SLIDING <br /> ��,;, CONCEALED ATTACHMENT SYSTEM, STANDARD 24 GAUGE SMOOTH 22, SEAM TAPE 3M CONSTRUCTION SEAMING TAPE$087 <br /> M ETAL. <br /> 6ass <br /> REG9STERED <br /> �t�arE� <br /> '�V(.� `�.�r� <br /> AVID V,4NDERVf?RT <br /> STA'i'E tlF V��0�9itlVG1'dN <br /> REVISION DATE <br /> s�s� REGISTERED <br /> RCHITECT <br /> � <br /> DAVID VANDERVORT <br /> STATE OF WASHINGTON <br /> WRB AND CLADDING WRB AND CLADDING WRB AND CLADDING WRB AND CLADDING DRAWN BY: MW <br /> � CHECKED BY: MBlDV <br /> �, <br /> i <br /> WALL SUBSTRATE: ,�%;��j; �� I <br /> SECURE DUPONT TYVEK WRB TO �;�.� / ��- � VERTICAL BATTENS AT 16" O.C., <br /> THE STUD OR OTHER NAIL BASE '� � i� I <br /> OR OOD STRUCTURAL PANEL(W.S.P.) MATERIAL I.E. WOOD SHEATHING. j �/ j SECURE DUPONT TYVEK WRB TO ;; j TYPICAL <br /> - FIRE PROTECTIVE SHEATHING FASTENERS SHOULD BE SPACED ;/ �j THE STUD OR OTHER NAIL BASE <br /> O V E R W.S.P. N O C L O S E R T H A N 6 A N D N O /,,�j M A T E R I A L I.E. W O O D S H E A T H I N G. ti G E N E R A L D E T A I L S . <br /> FARTHERTHAN 1$" ON VERTICAL , � ` FRSTENERS SHOULD BE SPACED � � <br /> STUD LINES. �;���� ��;� NO CLOSER THAN 6"AND NO � � <br /> jj�;� j � :���,�� FARTHER THAN 18" ON VERTICAL � <br /> j/��i j' `� ' / //��/%� STUD LINES. , <br /> � %i %i� �� E_=='" , <br /> VENTING STRIPS AT TOP AND <br /> � � ���� h . BOTTOM OF WALLS ANDATTHRU- <br /> i/� ALL VERTICAL SEAMS SHALL BE � /, ' <br /> ,�% � TAPED WITH DUPONT TYVEK TAPE. � � � <br /> ;�%�� WHEN WSTALLINGAS AN AIR ;�� ���,'���� � WALL FLASHING LOCATIONS <br /> j�� ��� BARRIER,ALSO TAPE ALL �����j' � <br /> /�' � / i HORIZONTAL SEAMS. i %� � <br /> � / ,, ; ,, , <br /> / � ��j;/ / ,;� ��i� � <br /> �� �/i � STEP 2: FIBER CEMENT CLADDING <br /> /,/ , /, � NAILAS REQUIRED PER TECHNICAL <br /> INSTALL WRB, SHINGLE FROM „ ,�j � '�/ /, / r - ���� �� ��� � �� p � MANU ACTURER�SSEE NOTE WP-1 <br /> � .� � <br /> � �� ���,� � ��i � � � �LA P�ING ALL JO NTS PER ST Pg2. ,.� � <br /> ,,,% " �� <br /> BOTTOM TO TOP. �' '� � � , <br /> /� � �������� �� . <br /> �i , � <br /> ;� ��� /� ,�,��� �,f SECURE WRB TO VERTICAL LEG OF --���� <br /> � ���� FLASHING W/SEALANT 1. � � <br /> � � � �� '���� ��`� ���� � <br /> '"� SECURE DUPONT TYVEK WRB TO <br /> �� /�, � <br /> ��%'' �%�i��� �%�' . STEP 1: , <br /> � � THE STUD OR OTHER NAIL BASE � /,,� / � � , '� � �:� , � CLADDING SHOWN CUTAWAYFOR <br /> � ! ���! �%� ��O � � NEXT COURSE OF WRB, LAP ��� O O <br /> , ;%� MATERIAL I.E. WOOD SHEATHING. �„�� % / f� ��:� SECURE THRU-WALL FLASHING TO CLARITY <br /> %i���� ��� FASTENERS SHOULD BE SPACED ///� �� � ��� ,: �� HORIZONTAL SEAM 6 12". USE TAPE THR UGH WRB. BOTTOM OF �� � <br /> i/i � � '� AT BOTTOM OF WRB TO SECURE TO WALL O <br /> �/ � NO CLOSER THAN 6"AND NO � � � � .� � �. � � � �: � � � ::� ��::: : � � ;.:: : �:��� � FLASHING TO BE MIN. 6" BELOW ' <br /> � �� FARTHER THAN 18 ON VERTICAL � / � � PREVIOUSLY INSTALLED COURSE. i I <br /> �����', STUD LINES. �� � ' �������� <br /> TOP OF WRB. SET FLASHING IN <br /> � �// � ,i � <br /> � �� � �� Q %�j��� `��� �.. �� :� ��� �� � ��O STU S WJ 8d GALVAN ZED NAI S AT L J INT <br /> / � ,,, /� � �� HORIZONTALAND VERTICA O <br /> /, �� , g / � 16 O.C. FLASHINGS PER TYPICAL DETAILS <br /> � �����% %� ROLL SHOULD BE PLUMB. BOTTOM o� f'`� ��:� � <br /> �� �'��� LD EXTEND `- �`� THRU-WALL FLASHING PER <br /> � / �; ;,�; EDGE OF ROLL SHOU _ � EXTERIOR ELEVATIONS. MAX. 20' <br /> � � � � OVER SILL PLATE INTERFACE AT <br /> �� � ��� LEAST 2". FOR MAXIMUM AIR z VERTICALLY BETWEEN THRU-WALL <br /> j'�� LEAKAGE REDUCTION WHEN � WRB FROM PREVIOUS STEP ���� �� FLASHING. � <br /> ; �� I N S T A L L I N G A S A N A I R A R R I E R�, ira <br /> ;; : ,; � <br /> %! SEAL WRAPATTHE BOTTOM O <br /> ,, ; �... . <br /> � ',, / THE WALL WITH SEALANT, DUPONT <br /> ';: TYVEK TAPE, DUPONT � <br /> '%� STRAIGHTFLASH OR DUPONT <br /> ��� FLASHING TAPE. EXTEND TO � <br /> ,� BOTTOM OF SILL PLATE FOR SLAB *UNROLL DIRECTLY OVER WINDOWS AND INSPECTION REQUIRED AT <br /> �� ON GRADE FOUNDATIONS. FOR DOORS. UPPER LAYER OF DUPONT <br /> � STUCCO EXTERIORS INTEGRATE COMPLETION OF THIS STEP <br /> WITH WEEP SCREED. TYVEK WRB SHOULD OVERLAP BOl-fOM <br /> LAYER BY A MINIMUM OF 6". <br /> STEP 1 - INSTALL PRIMARY WRB STEP 2 - SHINGLE PRIMARY WRB STEP 3 - THRU-WALL FLASHING STEP 3 - BATTENS AND CLADDING �P � 1 <br />