Laserfiche WebLink
H n R G I S <br /> � � � � mechanical � <br /> AIR DEVICE SCHEDULE e�e�t�;�a� <br /> telemmmunications <br /> security <br /> � � � � energy � <br /> MARK MANUFACTURER/ MODEL NO. SUPPLY/ DESCRIPTION TYPE NECK SIZE FACE SIZE SLOT AIRFLOW FRAME TYPE FINISH MATERtAL ACC. DETAIL/ NOTES MARK �zo�tn,�aa�e��e,suite600 <br /> RETURN / (BORDER TYPE) (LxW) (LxW) QTY/WIDTH RANGE DIAGRAM <br /> seattle,washington 98101 <br /> EXH (IN) (IN) (#/IN) < 25 NC EFERENCE t 206.A483376 w hargis.biz <br /> X - SUPPLY E)SQUARE CEILING DIFFUSE - 12" DIA 24x24 - - - - - - 1/M9.1 2 X <br /> � B. c� <br /> �� �o <br /> , ,�, <br /> A TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x22 24x24 UP TO 1600 1 WHITE ALUMINUM PFA 1/M9.1 1 A �` <br /> � � � . <br /> ��AL Ll� <br /> NOTES: !�(l�2ah <br /> 1. PROVIDE WfTH FACTORY CUSTOM COLOR FINISH. COORDINATE COLORS WITH ARCHITECT. <br /> 2.EXISTING SUPPLY DIFFUSER. T� � <br /> Drif tmier <br /> ROOFTOP HEAT PUMP SCHEDULE , <br /> MARK LOCATION AREA SERVED MANUFACTURER/ MODEL NO. VENT. COfL CON�IGURATION SUPPLY FAN SUPPLY FAN MOTOR HEATING COOLING FtLTER ELECTRICAL PHYSICAL MOUNTING/ CONTROL NOTES MARK A rc h 1 t e c t s � �•�• <br /> M I N O A M A X O A T Y P E M A X F L O W E S P R P M S P E E D H P T Y P E V l Q 1 CAP A C ITY OA EAT LAT OTAL CAP OA TEMP. EAT, WB S E E R QTY/SIZE V/Q J M C A M O C P LxWxH WEIGHT S U P P O R T D I A G R A M / <br /> (CFM (CFM) (CFM) (IN WC) CONTROL (MBH) TEMP. (DEG F) (DEG F) (MBH) (DEG F) (DEG F) (#)-(INxINxW) (INxINxIN) ��8�, SEQ�EN�E 7 9 8 3 Lear y 1�ay NE � <br /> (DEG F) <br /> HP-03 ROOF OPS SECURITY OFFICE TRANE/4WCC4024A100A 40 700 DOWNFLOW CENTRIFUGAL 700 0.5 1050 ECM 1/3 ECM 208/1 22.0 21.0 67.2 96.3 24.6 85 65.0 14.0 20x25x2 208/1 60 60 49x42x36 425 ROOF 1/M10.1 1-6 HP-03 Redmond, �VA 98052 <br /> ( 425 ) 881 — '7506 <br /> mailC dr iftmier .com <br /> NOTES: <br /> 1. EQUIPMENT SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. <br /> 2. PROVIDE WITH SINGLE POINT POWER CONNECTION, 14"TALL FACTORY CURB, 2" HWGED FILTER RACK, AND 100°/a ECONOMIZER CAPABLE MOTORIZED OSA DAMPER. <br /> 3. PROVIDE WITH BARE TERMINAL STRIP FOR CONNECTION TO BUILDING STANDARD DDC SYSTEM CONTROLLER. DO NOT PROVIDE FACTORY CONTROLLER. <br /> 4. PROVIDE WITH ELECTRIC HEATER. HEATER SHALL BE 2�8/1 /6 KW. <br /> 5. PROVIDE WITH MICROMETL OR EQUAL POWERED EXHAUST/ECONOMIZER COMBINATION. POWERED EXHAUST/ECONOMIZER SHALL BE 1/2 HP, SWGLE PHASE WITH FLA=4.6, MCA= 5.8, AND MOCP = 15. M <br /> 6. PROVIDE ALL WIRING AND CONTROL DEV�CES BETWEEN HP-03 AND POWERED EXHAUST. � � � <br /> � � � <br /> � � <br /> � Q <br /> O � <br /> � � <br /> EXISTING FTU UNIT SCHEDULE ,�;; �-.~ <br /> HEATING COIL FAN MOTOR O �• ~ <br /> � � W <br /> MARK LOCATION SERVES MANUFACTURER/MODEL NO. APPROVED MANUFACTURER PRIMARY AIR UNIT CFM CFM INLET OUTLET INLET OUT MBH GPM EWT LWT WATER HP V/0 FLA WEtGHT RUNOUT VALVE DIMENSIONS NOTES � � � <br /> MAX MIN DUCT DUCT SP SP PD SIZE TYPE (LxWxH) � � <br /> (CFM) (CFM) (IN) (IN) (IN) (IN) (°F) (°F) (FT) (LBS) (IN) (INxINxIN) , � , <br /> (E) FTU-001 OPEN COMPUTER ROOM 196A CLG OPEN COMPUTER ROOM 196A CLG NAILOR 35SW-3 ENVIROTEC (E)AHU-OA3 990 400 10" PER PLAN 0.8 0.5 24.23 2.42 125 105 1.5 FT 3l4 277/1 5.1 250 3/4" 3-WAY 36x18x18 1 � � � <br /> � � <br /> � � �` � <br /> � � z �-. <br /> NOTES: � � <br /> � <br /> 1. EQUIPMENT 1S EXISTING. SCHEDULE IS FOR TESTING, ADJUSTING, AND BALANCING PURPOSES ONLY. AIR BALANCE (E) FTU-001 TO CFM'S ON PLANS AND SCHEDULE. � �J.I <br /> � <br /> � <br /> � <br /> o Z � <br /> o � <br /> z - _ <br /> �... �.. <br /> o � � <br /> W � <br /> Z a N <br /> o � <br /> � �-- <br /> . MECHANICAL � <br />� EQUIPMENT <br /> SCHEDULE <br />� <br />� <br /> issuE DATE: 12 02 16 <br /> DRAWN BY: SF <br /> CHECKED BY: BBC <br /> PROJECT NUMBER <br />� 2� 606 <br /> SHEET NUMBER <br /> M0.2 <br />